Surface-functionalized 3D porous rGO-polysaccharide sphere composites for rapid selective protein adsorption from crude biological liquid

2020 ◽  
Vol 526 ◽  
pp. 146707
Author(s):  
Hyunjung Lee ◽  
Uijin Lee ◽  
Byung Joon Moon ◽  
Sang Hyun Lee ◽  
Yong-Beom Shin
2010 ◽  
Vol 25 (7) ◽  
pp. 770-774 ◽  
Author(s):  
Hui-Jie ZHANG ◽  
Xiang-Dong ZHU ◽  
Xin-Long WANG ◽  
Hong-Song FAN ◽  
Xing-Dong ZHANG

2020 ◽  
Vol 8 (45) ◽  
pp. 10392-10406
Author(s):  
Danielle L. Heichel ◽  
Ngoc Chau H. Vy ◽  
Shawn P. Ward ◽  
Douglas H. Adamson ◽  
Kelly A. Burke

Silk fibroin films were modified with zwitterionic and hydrophilic brush-like polymers via surface-initiated ATRP, resulting in surfaces that reduced protein adsorption and cell attachment.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Eduardo Anitua ◽  
Andreia Cerqueira ◽  
Francisco Romero-Gavilán ◽  
Iñaki García-Arnáez ◽  
Cristina Martinez-Ramos ◽  
...  

Abstract Background Calcium (Ca) is a well-known element in bone metabolism and blood coagulation. Here, we investigate the link between the protein adsorption pattern and the in vivo responses of surfaces modified with calcium ions (Ca-ion) as compared to standard titanium implant surfaces (control). We used LC–MS/MS to identify the proteins adhered to the surfaces after incubation with human serum and performed bilateral surgeries in the medial section of the femoral condyles of 18 New Zealand white rabbits to test osseointegration at 2 and 8 weeks post-implantation (n=9). Results Ca-ion surfaces adsorbed 181.42 times more FA10 and 3.85 times less FA12 (p<0.001), which are factors of the common and the intrinsic coagulation pathways respectively. We also detected differences in A1AT, PLMN, FA12, KNG1, HEP2, LYSC, PIP, SAMP, VTNC, SAA4, and CFAH (p<0.01). At 2 and 8 weeks post-implantation, the mean bone implant contact (BIC) with Ca-ion surfaces was respectively 1.52 and 1.25 times higher, and the mean bone volume density (BVD) was respectively 1.35 and 1.13 times higher. Differences were statistically significant for BIC at 2 and 8 weeks and for BVD at 2 weeks (p<0.05). Conclusions The strong thrombogenic protein adsorption pattern at Ca-ion surfaces correlated with significantly higher levels of implant osseointegration. More effective implant surfaces combined with smaller implants enable less invasive surgeries, shorter healing times, and overall lower intervention costs, especially in cases of low quantity or quality of bone.


Author(s):  
Yadong Chai ◽  
Yuri Maruko ◽  
Zizhen Liu ◽  
Motohiro Tagaya

The highly-oriented cylindrical mesoporous silica films were synthesized on the rubbing-treated polyimide, and effectively adsorbed the mesoscale biomolecules such as proteins and guided to be their anisotropic adsorption shapes.


2021 ◽  
Vol 13 (6) ◽  
pp. 7021-7036
Author(s):  
Emily Buck ◽  
Seunghwan Lee ◽  
Laura S. Stone ◽  
Marta Cerruti

2021 ◽  
Vol 11 (4) ◽  
pp. 1723
Author(s):  
Yuri D. Ivanov ◽  
Tatyana O. Pleshakova ◽  
Ivan D. Shumov ◽  
Andrey F. Kozlov ◽  
Irina A. Ivanova ◽  
...  

Flow-based coiled systems, through which a heat transfer fluid (such as glycerol) is pumped, are widely used for thermal stabilization of bioreactors and biosensor cuvettes and cells. Previously, using horseradish peroxidase (HRP) as a model protein, we have demonstrated that the incubation of a protein solution in a flow-based system over coiled pipe with flowing glycerol leads to a change in the adsorption properties of the protein macromolecules. Herein, we have studied the effect of the glycerol flow on the properties of HRP, the solution of which was placed differently: i.e., near either the inflow or the outflow linear sections of the pipe, while the coiled section of the pipe was shielded with a grounded metallic cover. Atomic force microscopy (AFM) has been employed in order to visualize the HRP protein macromolecules adsorbed from its solution onto the mica substrate surface. The quantity of adsorbed protein was estimated based on the AFM data. The enzymatic activity of HRP was estimated by spectrophotometry. We demonstrate that a change in the properties of HRP enzyme was observed after the incubation of its solution near the inflow/outflow linear sections of the pipe with flowing glycerol. Namely, after the incubation of HRP solution near the inflow section, a decrease in the protein adsorption onto mica was observed, but its enzymatic activity remained unchanged in comparison to the control sample. In another case, when the HRP solution was incubated near the outflow section, an increased protein adsorption was observed, while the enzyme exhibited considerably lower activity.


Langmuir ◽  
2021 ◽  
Author(s):  
Thuvarakhan Gnanasampanthan ◽  
Cindy D. Beyer ◽  
Wenfa Yu ◽  
Jana F. Karthäuser ◽  
Robin Wanka ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document