A paper disk equipped with graphene/polyaniline/Au nanoparticles/glucose oxidase biocomposite modified screen-printed electrode: Toward whole blood glucose determination

2014 ◽  
Vol 56 ◽  
pp. 77-82 ◽  
Author(s):  
Fen-Ying Kong ◽  
Sai-Xi Gu ◽  
Wei-Wei Li ◽  
Ting-Ting Chen ◽  
Qin Xu ◽  
...  
1997 ◽  
Vol 338 (1-2) ◽  
pp. 135-140 ◽  
Author(s):  
Sangita D. Kumar ◽  
A.V. Kulkarni ◽  
R. Kalyanraman ◽  
T.S. Krishnamoorthy

1969 ◽  
Vol 15 (8) ◽  
pp. 680-698 ◽  
Author(s):  
John W Rosevear ◽  
Kenneth J Pfaff ◽  
Frederick J Service ◽  
George D Molnar ◽  
Eugene Ackerman

Abstract A glucose oxidase-peroxidase method for continuous automated monitoring of blood glucose has been developed. The response is linear over the range 0-800 mg/100 ml. Sensitivity can be maintained for 24 hr or longer and can be restored by rinsing the analytic system with sulfuric acid to permit studies of longer than 48 hr in duration. A precision of ± 1% can be maintained between rinses for samples containing 100-600 mg of glucose per 100 ml. This method is satisfactorily specific for glucose: The response with other sugars is less than 1% of the response obtained with the same concentration of glucose. Ascorbic acid causes no significant inhibition of the response to glucose. The inhibition by uric acid has been reduced fifty-fold compared to that in other methods. Transit through the sampling catheter and analytic system requires 15 min. Timed from the first detectable response to a change in concentration, 25% of total response is achieved in 30 sec and 90% in 80 sec. Fifty percent of an oscillation with a half-period of 45 sec can be detected; no oscillations this short were observed in records of human blood glucose. Applicability and feasibility of this method have been demonstrated in over 2000 hr of repeated blood glucose recordings in 12 diabetic and 6 normal subjects.


1974 ◽  
Vol 20 (5) ◽  
pp. 606-607 ◽  
Author(s):  
Peter Kabasakalian ◽  
Sami Kalliney ◽  
Anita Westcott

Abstract The hydrogen peroxide produced from glucose by glucose oxidase action at pH 7 is determined by the peroxidase oxidative coupling of N,N-diethylaniline with 4-amino-antipyrine. A 20-µl sample of plasma or serum is reacted at room temperature for 10 min. The sensitivity of the method is such that 60 µg of glucose (300 mg/dl) in a final volume of 5 ml gives an absorbance of 0.8 at 553 nm with a 1-cm cell. Absorbances are linearly related to glucose concentrations as high as 10.00 g/liter.


1976 ◽  
Vol 22 (10) ◽  
pp. 1729-1731 ◽  
Author(s):  
I Kaufmann-Raab ◽  
H G Jonen ◽  
E Jähnchen ◽  
G F Kahl ◽  
U Groth

Abstract Acetaminophen, p-aminophenol, and oxyphenbutazone interfere with the glucose oxidase/peroxidase method for glucose. Structurally related compounds that lack a free phenolic hydroxyl group (acetanilide, aniline, and phenylbutazone) do not interfere. During the analytical procedure acetaminophen is consumed. One mole of acetaminophen leads to an apparent loss of four moles of glucose. The hexokinase/glucose-6-phosphate dehydrogenase method (Boehringer Hexokinase method) is not affected by these substances.


1969 ◽  
Vol 15 (12) ◽  
pp. 1248-1248

Abstract In Rosevear, J. W. et al: "Glucose Oxidase Method for Continuous Automated Blood Glucose Determination, 15:680, 1969 in the Journal, the bottom of the whole paragraph on page 681 should have read: For a range of 0-500 mg/100 ml, the error equivalent to ±0.2% transmittance would be ±5% of the true value at 50 mg/100 ml, ±2% at 100, ±1% at 200, and ±3% at 500 mg/100 ml. For a range of 0-250 mg/100 ml (30-100% transmittance), the error equivalent to ±0.2% transmittance would be at least ±2% at 50 mg/100 ml and ±1% at 100 mg/100 ml.


2011 ◽  
Vol 31 (9) ◽  
pp. 0900105
Author(s):  
陈星旦 Chen Xingdan ◽  
王动民 Wang Dongmin ◽  
卢启鹏 Lu Qipeng ◽  
丁海泉 Ding Haiquan

Sign in / Sign up

Export Citation Format

Share Document