High-Gravity Technology-Enhanced Activated Sludge Process for Municipal Wastewater Treatment

2021 ◽  
pp. 117279
Author(s):  
Wei Xu ◽  
Chun-Xiang Geng ◽  
Zheng-Qing Hou ◽  
Sheng Liu ◽  
Lei Wang ◽  
...  
2008 ◽  
Vol 58 (8) ◽  
pp. 1671-1677 ◽  
Author(s):  
A. F. van Nieuwenhuijzen ◽  
A. G. N. van Bentem ◽  
A. Buunnen ◽  
B. A. Reitsma ◽  
C. A. Uijterlinde

The (low loaded) biological nutrient removing activated sludge process is the generally accepted and applied municipal wastewater treatment method in the Netherlands. The hydraulical and biological flexibility, robustness and cost efficiency of the process for advanced removal of nutrients like nitrogen and phosphorus without (too much) chemicals results in a wide application of the activated sludge process within Dutch waterboards. Presumably, wastewater treatment plants will have to contribute to the improvement of the quality of the receiving surface waters by producing cleaner effluent. In this perspective, the Dutch research organisation STOWA initiated a research project entitled “The Boundaries of the Activated Sludge Process” to investigate the possibilities and limitations of activated sludge processes to improve the effluent quality. It is concluded that the activated sludge process as applied and operated at WWTP's in the Netherlands has the potential to perform even better than the current effluent discharge standards (10 mg Ntotal/l and 1 mg Ptotal/l). Reaching the B-quality effluent (<5mg Ntotal/l and <0.3 mg Ptotal/l) will be possible at almost all WWTPs without major adjustments under the conditions that:   the sludge load is below 0.06 kg BOD/kg TSS.d   the internal recirculation is above 20   the BOD/N ratio of the influent is above 3. Complying with the A-quality effluent (<2.2 Ntotal/l and <0.15 mg Ptotal/l) seems to be difficult (but not impossible) and requires more attention and insight into the activated sludge process. Optimisation measures to reach the A-quality effluent are more thorough and are mostly only achievable by additional construction works (addition of activated sludge volume, increasing recirculation capacity, etc.). It is furthermore concluded that the static HSA-results are comparable to the dynamic ASM-results. So, for fast determinations of the limits of technology of different activated sludge processes static modelling seems to by sufficient.


2013 ◽  
Vol 845 ◽  
pp. 538-542 ◽  
Author(s):  
Muhammad Sani Gaya ◽  
Norhaliza Abdul Wahab ◽  
Yahya M. Sam ◽  
Sharatul Izah Samsuddin

Activated sludge process is the most efficient technique used for municipal wastewater treatment plants. However, a pH value outside the limit of 6-9 could inhibit the activities of microorganisms responsible for treating the wastewater, and low pH value may cause damage to the treatment system. Therefore, prediction of pH value is essential for smooth and trouble-free operation of the process. This paper presents an adaptive neuro-fuzzy inference system (ANFIS) model for effluent pH quality prediction in the process. For comparison, artificial neural network is used. The model validation is achieved through use of full-scale data from the domestic wastewater treatment plant in Kuala Lumpur, Malaysia. Simulation results indicate that the ANFIS model predictions were highly accurate having the root mean square error (RMSE) of 0.18250, mean absolute percentage deviation (MAPD) of 9.482% and the correlation coefficient (R) of 0.72706. The proposed model is efficient and valuable tool for the activated sludge wastewater treatment process.


1991 ◽  
Vol 23 (4-6) ◽  
pp. 1097-1106 ◽  
Author(s):  
H. Nakazawa ◽  
K. Tanaka

Mathematical models based on the kinetic aspect of the sequencing batch activated sludge process were developed to explain the characteristics of the process treating municipal wastewater. These models are a steady-state model dealing with the overall relationship between biomass concentrations in a reactor and operational conditions of the process, and a kinetic model dealing with the behaviors of biomass and substrate in a reactor within one cycle time of the process. Applying these mathematical models for the results of pilot-scale experiments for municipal wastewater treatment, reasonable parameters' values were obtained and the effects of operating strategies including the aeration time ratio and the solids retention time became clear for the process performance.


Author(s):  
A. Kuokkanen ◽  
K. Blomberg ◽  
A. Mikola ◽  
M. Heinonen

Abstract Nitrous oxide emissions can contribute significantly to the carbon footprint of municipal wastewater treatment plants even though emissions from conventional nitrogen removal processes are assumed to be moderate. An increased risk for high emissions can occur in connection with process disturbances and nitrite (NO2−) accumulation. This work describes the findings at a large municipal wastewater treatment plant where the levels of NO2− in the activated sludge process effluent were spontaneously and strongly increased on several activated sludge lines which was suspected to be due to shortcut nitrogen removal that stabilized for several months. The high NO2− levels were linked to a dramatic increase in nitrous oxide (N2O) emissions. As much as over 20% of the daily influent nitrogen load was emitted as N2O. These observations indicate that highly increased NO2− levels can occur in conventional activated sludge processes and result in high nitrous oxide emissions. They also raise questions concerning the risk of increased greenhouse gas (GHG) emissions of the nitritation-denitritation processes – although the uncontrolled nature of the event described here must be taken into consideration – and underline the importance of continuous monitoring and control of N2O emissions.


1998 ◽  
Vol 38 (3) ◽  
pp. 167-172
Author(s):  
Jin Duanyao ◽  
Wang Baozhen ◽  
Wang Lin

The Zhen'an Wastewater Treatment Plant in Foshan City, Guangdong Province, China is a newly built large municipal wastewater treatment plant in south China, situated in the southeast of the famous ancient Foshan City, has a treatment capacity of 100,000 m3/d, serves an area of 32 km2 and 220,000 P. E., occupies 7 ha area with a total investment of 220 million RMB (about 26.5 million U.S dollar), which was put into operation in December 1995. As it is difficult to design and operate the wastewater treatment plant because of the low organic concentration of its influent, the simplified A/O activated sludge process without primary treatment for simultaneous removal of phosphorus and ammonia nitrogen was employed to design the plant, by which, the wastewater is treated very well, with higher effluent quality than the traditional activated sludge process, while the capital and O/M costs are lower than the latter.


2006 ◽  
Vol 53 (4-5) ◽  
pp. 357-366 ◽  
Author(s):  
Y. Okayasu ◽  
H. Tanaka ◽  
T. Inui ◽  
Y. Tanaka

The effect of potassium cyanide (KCN) on nitrification processes in municipal wastewater treatment plants was studied by batch nitrification tests, which indicated that nitrification processes tend to be inhibited at a lower KCN concentration than the present discharge standard to sewerage. The experiment of the biosensor using nitrifying bacteria was also conducted for continuous monitoring of nitrification inhibitor in influent wastewater, and demonstrated that the biosensor can detect KCN at as low as EC10 of the abovementioned batch nitrification test. Moreover, to determine the effectiveness of application of the biosensor to avoid the impact of KCN due to an accidental spillage in a sewerage system, KCN was intentionally injected into the experimental models of activated sludge process equipped both with and without the biosensor. The model with the biosensor that could detect KCN could divert the wastewater including KCN to a refuge tank, which resulted in the avoidance of upset of the activated sludge process. On the other hand, the model without the biosensor was upset in the nitrification process due to KCN. Such differences demonstrate the effectiveness of the biosensor applied to countermeasures of an accidental spillage of toxic chemicals to avoid upset of nitrification in municipal wastewater treatment plants.


Sign in / Sign up

Export Citation Format

Share Document