Assessment of sample cleanup and matrix effects in the pesticide residue analysis of foods using postcolumn infusion in liquid chromatography–tandem mass spectrometry

2011 ◽  
Vol 1218 (46) ◽  
pp. 8399-8410 ◽  
Author(s):  
Stefan Kittlaus ◽  
Julia Schimanke ◽  
Guenther Kempe ◽  
Karl Speer
2013 ◽  
Vol 59 (2) ◽  
pp. 372-380 ◽  
Author(s):  
Julianne Cook Botelho ◽  
Christopher Shacklady ◽  
Hans C Cooper ◽  
Susan S-C Tai ◽  
Katleen Van Uytfanghe ◽  
...  

BACKGROUND We developed and evaluated a candidate reference measurement procedure (RMP) to standardize testosterone measurements, provide highly accurate and precise value assignments for the CDC Hormone Standardization Program, and ensure accurate and comparable results across testing systems and laboratories. METHODS After 2 liquid/liquid extractions of serum with a combination of ethyl acetate and hexane, we quantified testosterone by isotope-dilution liquid chromatography–tandem mass spectrometry with electrospray ionization in the positive ion mode monitoring 289→97 m/z (testosterone) and 292→112 m/z (3C13 testosterone). We used calibrator bracketing and gravimetric measurements to give higher specificity and accuracy to serum value assignments. The candidate RMP was evaluated for accuracy by use of NIST-certified reference material SRM971 and validated by split-sample comparison to established RMPs. We evaluated intraassay and interassay imprecision, measurement uncertainty, potential interferences, and matrix effects. RESULTS A weighted Deming regression comparison of the candidate RMP to established RMPs showed agreement with no statistical difference (slope 0.99, 95% CI 0.98–1.00, intercept 0.54, 95% CI −1.24 to 2.32) and a bias of ≤0.3% for NIST SRM971. The candidate RMP gave maximum intraassay, interassay, and total percent CVs of 1.5%, 1.4%, and 1.7% across the concentrations of testosterone typically found in healthy men and women. We tested structural analogs of testosterone and 125 serum samples and found no interferences with the measurement. CONCLUSIONS This RMP for testosterone can serve as a higher-order standard for measurement traceability and can be used to provide an accuracy base to which routine methods can be compared in the CDC Hormone Standardization Program.


2017 ◽  
Vol 80 (12) ◽  
pp. 2112-2118 ◽  
Author(s):  
Dan Hu ◽  
Xu Xu ◽  
Tian Cai ◽  
Wei-Ying Wang ◽  
Chun-Jie Wu ◽  
...  

ABSTRACTA rapid and sensitive analytical method based on high-performance liquid chromatography–tandem mass spectrometry was developed and validated for the determination of isopyrazam (IZM) and azoxystrobin (AZT) in cucumbers. A modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method was used as the pretreatment procedure. The samples were extracted with acetonitrile and cleaned up with octadecylsilyl silica (C18) and graphite carbon black. The proposed method resulted in satisfactory recovery of IZM and AZT (91.48 to 114.62%), and relative standard deviations were less than 13.1% at fortification concentrations of 1, 20, and 500 μg kg−1 (n = 3). The limits of quantification for IZM and AZT were 0.498 and 0.499 μg kg−1, respectively, which are far below the maximum residue level (0.5 mg kg−1) established for this type of sample. Matrix effects were also evaluated. This study established a sensitive and fast method for the detection of IZM and AZT in cucumber samples.


2010 ◽  
Vol 397 (6) ◽  
pp. 2477-2490 ◽  
Author(s):  
Fulvia Caretti ◽  
Alessandra Gentili ◽  
Annalisa Ambrosi ◽  
Lucia Mainero Rocca ◽  
Maurizio Delfini ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document