Hydrophilic interaction and reversed phase mixed-mode liquid chromatography coupled to high resolution tandem mass spectrometry for polar lipids analysis

2016 ◽  
Vol 1477 ◽  
pp. 47-55 ◽  
Author(s):  
Sara Granafei ◽  
Pietro Azzone ◽  
Vito Alessandro Spinelli ◽  
Ilario Losito ◽  
Francesco Palmisano ◽  
...  
Molecules ◽  
2021 ◽  
Vol 26 (8) ◽  
pp. 2123
Author(s):  
Luboš Fical ◽  
Maria Khalikova ◽  
Hana Kočová Vlčková ◽  
Ivona Lhotská ◽  
Zuzana Hadysová ◽  
...  

Two new ultra-high performance liquid chromatography (UHPLC) methods for analyzing 21 selected antivirals and their metabolites were optimized, including sample preparation step, LC separation conditions, and tandem mass spectrometry detection. Micro-solid phase extraction in pipette tips was used to extract antivirals from the biological material of Hanks balanced salt medium of pH 7.4 and 6.5. These media were used in experiments to evaluate the membrane transport of antiviral drugs. Challenging diversity of physicochemical properties was overcome using combined sorbent composed of C18 and ion exchange moiety, which finally allowed to cover the whole range of tested antivirals. For separation, reversed-phase (RP) chromatography and hydrophilic interaction liquid chromatography (HILIC), were optimized using extensive screening of stationary and mobile phase combinations. Optimized RP-UHPLC separation was carried out using BEH Shield RP18 stationary phase and gradient elution with 25 mmol/L formic acid in acetonitrile and in water. HILIC separation was accomplished with a Cortecs HILIC column and gradient elution with 25 mmol/L ammonium formate pH 3 and acetonitrile. Tandem mass spectrometry (MS/MS) conditions were optimized in both chromatographic modes, but obtained results revealed only a little difference in parameters of capillary voltage and cone voltage. While RP-UHPLC-MS/MS exhibited superior separation selectivity, HILIC-UHPLC-MS/MS has shown substantially higher sensitivity of two orders of magnitude for many compounds. Method validation results indicated that HILIC mode was more suitable for multianalyte methods. Despite better separation selectivity achieved in RP-UHPLC-MS/MS, the matrix effects were noticed while using both chromatographic modes leading to signal enhancement in RP and signal suppression in HILIC.


Separations ◽  
2020 ◽  
Vol 7 (2) ◽  
pp. 25 ◽  
Author(s):  
Eduardo Sommella ◽  
Emanuela Salviati ◽  
Simona Musella ◽  
Veronica Di Sarno ◽  
Francesco Gasparrini ◽  
...  

In this work, two online comprehensive two-dimensional liquid chromatography platforms, namely Hydrophilic interaction liquid chromatography × Reversed phase (HILIC × RP) and Reversed phase × Reversed Phase (RP × RP) coupled to mass spectrometry, were compared for the analysis of complex peptide samples. In the first dimension, a HILIC Amide and C18 Bioshell peptide (150 × 2.1 mm, 1.7 and 2.0 μm) columns were selected, while, in the second dimension, a short C18 (50 × 3.0 mm, 2.7 μm) Bioshell peptide column was used. Two C18 trapping columns (10 × 3.0 mm, 1.9 μm), characterized by high retention and surface area, were employed as modulation interface in both HILIC × RP and RP × RP methods. The LC × LC platforms were coupled to UV and tandem mass spectrometry detection and tested for the separation and identification of two gastro-intestinal digests of commercial microalgae formulations (Spirulina Platensis and Klamath). Their performances were evaluated in terms of peak capacity, maximum number and properties of identified phycocyanin peptides. Our results showed that the HILIC × RP approach provided the highest peak capacity values (nc HILIC × RP: 932 vs. nc RP × RP: 701) with an analysis time of 60 min, while the RP × RP approach was able to identify a slight higher number of phycocyanin derived peptides (HILIC × RP: 88 vs. RP × RP: 103). These results point out the flexibility and potential of HILIC × RP and RP × RP based on trapping modulation for peptide mapping approaches.


Sign in / Sign up

Export Citation Format

Share Document