Study of relative response factors and mass balance in forced degradation studies with liquid chromatography/photo-diode array detector/evaporative light scattering detector/mass spectrometry system

2017 ◽  
Vol 1512 ◽  
pp. 61-70 ◽  
Author(s):  
Paula Hong ◽  
Aaron D. Phoebe ◽  
Michael D. Jones
2011 ◽  
Vol 94 (1) ◽  
pp. 71-76 ◽  
Author(s):  
Mieczysław Sajewicz ◽  
Dorota Staszek ◽  
Łukasz Wojtal ◽  
Teresa Kowalska ◽  
Michał Ł Hajnos ◽  
...  

Abstract This study is focused on an important family of the sage (Salvia) species, with Salvia officinalis L. having a long-established position in European traditional medicine. Binary fingerprints (chromatographic profiles) of six different sage species were compared using HPLC coupled with two different detectors: the diode-array detector and the evaporative light-scattering detector. Advantages of using binary fingerprinting over single-detector fingerprinting are demonstrated and discussed, with selected examples. Experimental data are provided for a comparison of the chemical composition of sage samples originating from two harvesting seasons (2007 and 2008). A number of phytochemical standards (i.e., certain phenolic acids, flavonoids, and coumarin) were used that allowed identification and semiquantitative estimation of these particular compounds in the analyzed methanol extracts.


2011 ◽  
Vol 94 (2) ◽  
pp. 503-512 ◽  
Author(s):  
Tarek S Belal ◽  
Rasha A Shaalan ◽  
Rim S Haggag

Abstract A simple, rapid, and selective HPLC-diode array detector method was developed for the simultaneous determination of lidocaine hydrochloride (LD) and cetylpyridinium chloride (CPC) in two combined pharmaceutical formulations. Effective chromatographic separation was achieved on a Zorbax SB-C8 (4.6 250 mm, 5 m particle size) column with gradient elution using a mobile phase composed of 0.05 M phosphoric acid and acetonitrile. The gradient elution started with 25 (v/v) acetonitrile, ramped up linearly to 85 in 5 min, and then was constant until the end of the run. The mobile phase was pumped at a flow rate of 1.2 mL/min. The multiple wavelength detector was set at 214 and 258 nm, and quantification of the analytes was based on measuring their peak areas. The retention times for LD and CPC were about 3.4 and 7.3 min, respectively. The reliability and analytical performance of the proposed HPLC procedure were statistically validated with respect to linearity, range, precision, accuracy, selectivity, robustness, LOD, and LOQ. Calibration curves were linear in the range of 5200 and 10400 g/mL for LD and CPC, respectively, with correlation coefficients >0.999. The proposed method was proven to be stability-indicating by the resolution of the two analytes from the related substance and potential impurity (2,6-dimethylaniline) as well as from forced-degradation products. The validated HPLC method was extended to the analysis of LD and CPC in two combined oral gel preparations for which the two analytes were successfully resolved from the pharmaceutical adjuvants and quantified with recoveries not less than 97.9.


Marine Drugs ◽  
2021 ◽  
Vol 19 (6) ◽  
pp. 321
Author(s):  
Maria Orfanoudaki ◽  
Anja Hartmann ◽  
Julia Mayr ◽  
Félix L. Figueroa ◽  
Julia Vega ◽  
...  

This study presents the validation of a high-performance liquid chromatography diode array detector (HPLC-DAD) method for the determination of different mycosporine-like amino acids (MAAs) in the red alga Bostrychia scorpioides. The investigated MAAs, named bostrychines, have only been found in this specific species so far. The developed HPLC-DAD method was successfully applied for the quantification of the major MAAs in Bostrychia scorpioides extracts, collected from four different countries in Europe showing only minor differences between the investigated samples. In the past, several Bostrychia spp. have been reported to include cryptic species, and in some cases such as B. calliptera, B. simpliciuscula, and B. moritziana, the polyphyly was supported by differences in their MAA composition. The uniformity in the MAA composition of the investigated B. scorpioides samples is in agreement with the reported monophyly of this Bostrychia sp.


Sign in / Sign up

Export Citation Format

Share Document