Hollow urchin-shaped manganese dioxide microspheres immobilized acetylcholinesterase for rapid screening inhibitors from traditional herbal medicines

2022 ◽  
pp. 462824
Author(s):  
Jia Liu ◽  
Wei Ha ◽  
Hai-Xia Zhang ◽  
Yan-Ping Shi
2019 ◽  
Vol 11 (38) ◽  
pp. 4868-4874
Author(s):  
Peng Tan ◽  
Xichuan Wei ◽  
Haizhu Zhang ◽  
Ming Niu ◽  
Dingkun Zhang

This study has provided a practical analytical method for rapid screening and quantitative analysis of 130 pesticide residues in herbal medicines based on the Kovats retention index.


2017 ◽  
Vol 2017 ◽  
pp. 1-13 ◽  
Author(s):  
Yunshuang Fan ◽  
Yamei Li ◽  
Yuanyuan Wu ◽  
Lixin Li ◽  
Yuming Wang ◽  
...  

Simiao Wan (SMW), an important multiherbal formula used in traditional Chinese medicine, is extensively used to treat rheumatoid arthritis. However, the knowledge of the bioactive components of SMW remains unclear. Thus, gas chromatography–mass spectrometry (GC-MS) and liquid chromatography–mass spectrometry (LC-MS) were used to analyze the chemical constituents of volatile and nonvolatile extracts of SMW, as well as its absorbed components in rat plasma after oral SMW administration. Identification of several compounds was enabled by comparison of retention times, MS spectra, and MS/MS spectral data with the standard substance and reference materials reported in the literature. In the volatile extracts, GC-MS identified 26 compounds in vitro, three of which observed in blood by GC-MS. In the nonvolatile extracts, LC-MS identified 49 compounds in SMW; 18 compounds containing 7 prototype compounds, 5 metabolites, and 6 unknown compounds were absorbed by blood. The proposed GC-MS and LC-MS method was appropriate not only for the rapid screening and identification of multiple components of an SMW extract but also for screening its bioactive constituents in vivo. The proposed method could be a promising tool for the quality control of other Chinese herbal medicines.


2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Qi Liang ◽  
Yue Zhuang ◽  
Jun Ma ◽  
Jinyan Wang ◽  
Rui Feng ◽  
...  

Herbal weight loss drugs are becoming more widely used in the fight against obesity, but ineffective regulation of these products have resulted in harmful additives. These products may contain adulterants such as sibutramine hydrochloride that may result in serious adverse health events including death. This work established a color precipitation reaction-based rapid screening method for illegal adulteration of sibutramine hydrochloride in natural herbal medicines (NHM) and dietary supplements (DS). While a variety of chromatography- and electrophoresis-based systems have been reported to measure this analyte, they generally suffer from high costs, complicated sample preparation, and a costly analytical infrastructure. In contrast, we present a simple, handheld kit to assay for sibutramine. The performance metrics of this tool include an average detection time of approximately 3 minutes, which is markedly shorter than conventional methods (HPLC or HPLC-MS, etc.), a detection limit of 0.1 mg per aliquot, and an accuracy of 99.02% (n = 820). More strikingly, the sensitivity is 100% (n = 278), and the specificity is 98.52% (n = 542). The rapid test kit developed from this screening method was evaluated by FDA. In summary, this screening method is a rapid, simple, and low-cost tool for the detection of sibutramine in NHM and DS with superior selectivity and sensitivity. For these reasons, this method is especially suitable for underdeveloped settings because it can be employed onsite without any instrumentation. In addition, this approach could rapidly exclude most of the negative samples to boost efficiency in large-scale samples assay. If necessary, positive samples can undergo further alternate testing methods to confirm the positive results of sibutramine hydrochloride content.


2019 ◽  
Vol 25 (5) ◽  
pp. 419-427
Author(s):  
Changchuan Guo ◽  
Ke Li ◽  
Sheng Xing ◽  
Hua Sun ◽  
Feng Shi ◽  
...  

In this work, a method combining ultra-high performance liquid chromatography and hybrid quadrupole-Orbitrap high-resolution mass spectrometry (HR-MS) was developed and validated for use in the simultaneous screening, identification, and quantification of 21 synthetic dyes in herbal medicines. To optimize the chromatographic conditions, we used a combined Full mass scan and data-dependent MS/MS (Full MS/dd-MS2) approach in positive and negative ion mode. Under this mode, selected ions with given fragmentation energy were subjected to a dd-MS2 scan following a Full MS scan. The selectivity of this method was effectively improved using 70,000 full width at half maximum mass resolution and narrow mass window (typically 5 ppm), and a single injection was sufficient for simultaneous identification and quantification of 21 synthetic dyes within 10 min. The combined method was fully validated and complies with all criteria for selectivity, sensitivity, calibration curve linearity, accuracy, precision, recovery, matrix effect, and stability. All analytes showed excellent linear relationships as all the coefficients of determination ( r2) are greater than 0.9978 over wide ranges of concentrations (e.g. 1.0–500 ng/mL for sunset yellow). The validated method was employed to detect synthetic dyes in herbal medicines and was demonstrated to provide a reliable technical basis for drug regulation and public health protection.


1970 ◽  
Vol 102 (2) ◽  
pp. 237-237
Author(s):  
R. M. McDonald

Sign in / Sign up

Export Citation Format

Share Document