scholarly journals Study on the influence of ventilation parameters on the airflow temperature in excavation roadway and ventilation duct

Author(s):  
Jiuzhu Wang ◽  
Cuifeng Du ◽  
Yuan Wang
Keyword(s):  
Energies ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2760
Author(s):  
Ruiye Li ◽  
Peng Cheng ◽  
Hai Lan ◽  
Weili Li ◽  
David Gerada ◽  
...  

Within large turboalternators, the excessive local temperatures and spatially distributed temperature differences can accelerate the deterioration of electrical insulation as well as lead to deformation of components, which may cause major machine malfunctions. In order to homogenise the stator axial temperature distribution whilst reducing the maximum stator temperature, this paper presents a novel non-uniform radial ventilation ducts design methodology. To reduce the huge computational costs resulting from the large-scale model, the stator is decomposed into several single ventilation duct subsystems (SVDSs) along the axial direction, with each SVDS connected in series with the medium of the air gap flow rate. The calculation of electromagnetic and thermal performances within SVDS are completed by finite element method (FEM) and computational fluid dynamics (CFD), respectively. To improve the optimization efficiency, the radial basis function neural network (RBFNN) model is employed to approximate the finite element analysis, while the novel isometric sampling method (ISM) is designed to trade off the cost and accuracy of the process. It is found that the proposed methodology can provide optimal design schemes of SVDS with uniform axial temperature distribution, and the needed computation cost is markedly reduced. Finally, results based on a 15 MW turboalternator show that the peak temperature can be reduced by 7.3 ∘C (6.4%). The proposed methodology can be applied for the design and optimisation of electromagnetic-thermal coupling of other electrical machines with long axial dimensions.


Proceedings ◽  
2020 ◽  
Vol 58 (1) ◽  
pp. 19
Author(s):  
Jari Huttunen ◽  
Olli Salmela ◽  
Topi Volkov ◽  
Eva Pongrácz

The use of mobile data has increased and will continue to increase in the future, because more data is moving to wireless networks such as 5G. Cooling energy need is also expected to increase in indoor telecom rooms, and can be as high as the equipment’s own power consumption. The world’s first liquid Base Transceiver Station (BTS) was adopted into commercial use in 2018, in Helsinki, Finland. Conventional air-cooled BTS hardware was converted into liquid-cooled BTS equipment. Heat from the BTS was pumped out of the site room, and thus ventilation or air conditioning was not needed for the heat load from the BTS. Heat stored in the liquid was released into the ventilation duct of the building, still providing annual cooling energy savings of 70%, when compared to air cooling. In the future, 80% of the total dissipated energy, 13450 kWh/a in total, can potentially be used for heating purposes. In terms of CO2 emissions, adapting liquid cooling showed an 80% reduction potential when compared to air cooling.


2022 ◽  
Vol 188 ◽  
pp. 108525
Author(s):  
Lifu Wu ◽  
Lei Wang ◽  
Shuaiheng Sun ◽  
Xinnian Sun

2010 ◽  
Vol 9 (3) ◽  
pp. 241-248
Author(s):  
Salonen Eero-Matti ◽  
Rauno Holopainen