scholarly journals Piston-wind ventilation strategy for thermal environment improvement of heat-supply compartment in utility tunnels

Author(s):  
Xuemei Wang ◽  
Tiantian Zhang ◽  
Yufei Tan ◽  
Zhuo Liu
2021 ◽  
Vol 64 (6) ◽  
pp. 1955-1966
Author(s):  
Xiaoshuai Wang ◽  
Jiangong Li ◽  
Jiegang Wu ◽  
Qianying Yi ◽  
Xinlei Wang ◽  
...  

HighlightsThe placement and operation of exhaust fans was assessed using CFD simulation.The effective temperature was used to evaluate the indoor thermal environment.The placement and operation of the exhaust fans mainly affected the airflow patterns in the part of the layer house closest to the fans.Abstract. The thermal environment inside a layer house significantly affects the growth, production, and health of the hens. Tunnel ventilation systems have been widely applied to control the indoor climate and air quality for large-scale poultry facilities around the world. Generally, only a few of the exhaust fans operate during mild seasons (spring and fall) in a tunnel-ventilated layer house depending on the outside air temperature. The decision about which exhaust fans to turn on affects the indoor airflow pattern and temperature distribution. However, little research has been reported that investigated the effects of the locations of exhaust fans on ventilation performance. In this study, a computational fluid dynamics (CFD) model was built and validated using field-measured data. The CFD model was then used to evaluate different ventilation strategies (combinations of exhaust fans) in a typical tunnel-ventilated layer house during the fall. The effective temperature was used to assess the performance of different ventilation strategies. Results showed that the locations of the exhaust fans significantly affected the indoor thermal environment, especially in the part of the house closest to the fans, because different locations of operating fans can generate different airflow patterns and affect the airflow through the animal-occupied zone. Based on the simulations, we conclude that the placement and operation of the exhaust fans can be optimized. Turning on the fans that are lower to the ground or near the sidewalls will result in more air bypassing the animal-occupied zones. Our results can help select the best ventilation strategy during the spring and fall in layer houses with tunnel ventilation systems. Keywords: Airflow distribution, Effective temperature distribution, Indoor thermal environments, Ventilation strategy.


2012 ◽  
Author(s):  
Alberto Miguel ◽  
Nelson Rodrigues ◽  
Senhorinha Teixeira ◽  
Jose Teixeira ◽  
Ricardo Oliveira

Author(s):  
S. I. Nefedkin ◽  
A. O. Barsukov ◽  
M. I. Mozgova ◽  
M. S. Shichkov ◽  
M. A. Klimova

The paper proposes an alternative scheme of guaranteed electricity and heat supply of an energy-insulated facility with a high potential of wind energy without the use of imported or local fuel. The scheme represents a wind power complex containing the park of wind generators located at the points with high wind potential. The wind generators provide guaranteed power supply even in periods of weak wind. For heat supply of the consumer, all surplus of the electric power goes on thermoelectric heating of water in tanks of accumulators, and also on receiving hydrogen by a method of electrolysis of water. The current heat supply is carried out with the use of hot water storage tanks, and the heat supply during the heat shortage is carried out by burning the stored hydrogen in condensing hydrogen boilers. We have developed the algorithm of calculation and the program "Wind in energy" which allows calculating annual balance of energy and picking up necessary quantity of the equipment for implementation of the scheme proceeding from the annual schedule of thermal and electric loading, and also potential of wind energy in the chosen region. The calculation-substantiation of the scheme proposed in relation to the real energy-insulated object Ust-Kamchatsk (Kamchatka) is carried out. The equipment for the implementation of an alternative energy supply scheme without the use of imported fuel is selected and compared with the traditional energy supply scheme based on a diesel power plant and a boiler house operating on imported fuel. With the introduction of an alternative power supply scheme, the equipment of the traditional scheme that has exhausted its resource can be used for backup power supply. Using climate databases, a number of energy-insulated facilities in the North and East of Russia with high wind energy potential are considered and the conditions for the successful implementation of the energy supply scheme are analyzed. This requires not only a high average annual wind speed, but also a minimum number of days of weak wind. In addition, it is necessary that the profile of the wind speed distribution in the annual section coincides with the profile of the heat load consumption.


Sign in / Sign up

Export Citation Format

Share Document