scholarly journals Effect of functionally-graded interphase on the elasto-plastic behavior of nylon-6/clay nanocomposites; a numerical study

2020 ◽  
Author(s):  
Maziyar Bazmara ◽  
Mohammad Silani ◽  
Iman Dayyani
2021 ◽  
Vol 138 (27) ◽  
pp. 50648 ◽  
Author(s):  
Roberto Yáñez‐Macías ◽  
Jorge E. Rivera‐Salinas ◽  
Silvia Solís‐Rosales ◽  
Daniel Orduña‐Altamirano ◽  
David Ruíz‐Mendoza ◽  
...  

2020 ◽  
Vol 9 (1) ◽  
pp. 256-264
Author(s):  
Dinkar Sharma ◽  
Ramandeep Kaur

AbstractThis paper presents, numerical study of stress field in functionally graded material (FGM) hollow cylinder by using finite element method (FEM). The FGM cylinder is subjected to internal pressure and uniform heat generation. Thermoelastic material properties of FGM cylinder are assumed to vary along radius of cylinder as an exponential function of radius. The governing differential equation is solved numerically by FEM for isotropic and anistropic hollow cylinder. Additionally, the effect of material gradient index (β) on normalized radial stresses, normalized circumferential stress and normalized axial stress are evaluated and shown graphically. The behaviour of stress versus normalized radius of cylinder is plotted for different values of Poisson’s ratio and temperature. The graphical results shown that stress field in FGM cylinder is influenced by some of above mentioned parameters.


Polymer ◽  
2004 ◽  
Vol 45 (7) ◽  
pp. 2321-2331 ◽  
Author(s):  
T.D. Fornes ◽  
D.L. Hunter ◽  
D.R. Paul

2016 ◽  
Vol 08 (04) ◽  
pp. 1650054 ◽  
Author(s):  
Zeinab Mazarei ◽  
Mohammad Zamani Nejad ◽  
Amin Hadi

An exact closed-form analytical solution is presented to solve the thermo-elasto-plastic problem of thick-walled spherical vessels made of functionally graded materials (FGMs). Assuming that the inner surface is exposed to a uniform heat flux, and that the outer surface is exposed to an airstream. The heat conduction equation for the one-dimensional problem in spherical coordinates is used to obtain temperature distribution in the sphere. Material properties are graded in the thickness direction according to a power law distribution, whereas the Poisson’s ratio is kept constant. The Poisson’s ratio due to slight variations in engineering materials is assumed constant. The plastic model is based on von Mises yield criterion and its associated flow rules under the assumption of perfectly plastic material behavior. For various values of inhomogeneity constant, the so-obtained solution is then used to study the distribution of limit heat flux, displacement and stresses versus the radial direction. Moreover, the effect of increasing the heat flux and pressure on the propagation of the plastic zone are investigated. Furthermore, the effect of change in Poisson’s ratio on the value of the critical material parameter is demonstrated. The present study is also validated by comparing the numerical results for thick elasto-plastic spherical shells available in the literature. To the best of the authors’ knowledge, in previous studies, exact thermo-elasto-plastic behavior of FGM thick-walled sphrical pressure vessels has not investigated.


2021 ◽  
pp. 114833
Author(s):  
Weihua Fang ◽  
Huifeng Hu ◽  
Tiantang Yu ◽  
Tinh Quoc Bui

Author(s):  
Amirtaha Taebi ◽  
Fardin Khalili ◽  
Amirtaher Taebi

In orthopedics, the current internal fixations often use screws or intramedullary rods that obstruct bone material. In this paper, an internal implant was modelled as a hollow cylindrical sector made of a functionally graded material (FGM), which will hold bone in place with less obstruction of bone surface. Functionally graded implant was considered as an inhomogeneous composite structure, with continuously compositional variation from a ceramic at the outer diameter to a metal at the inner diameter. The buckling behavior of the implant was numerically analyzed using a finite element analysis software (ANSYS), and the structural stability of the implant was assessed. The buckling critical loads were calculated for different fixation lengths, cross sectional areas, and different sector angles. These critical loads were then compared with the critical loads of an FGM hollow cylinder with the same cross sectional area. Results showed that the critical load of the hollow cylindrical sector was ∼ 63%, ∼ 70%, and ∼ 73% of the hollow cylinder for different fixation lengths, cross sectional areas, and sector angles, respectively. Further investigations are warranted to study the relation between the composition profile and the implant stability, which can lead to batter internal fixation solutions.


Sign in / Sign up

Export Citation Format

Share Document