scholarly journals The Impact of an Ideal Dynamic Building Envelope on the Energy Performance of Low Energy Office Buildings

2014 ◽  
Vol 58 ◽  
pp. 185-192 ◽  
Author(s):  
Francesco Goia ◽  
Ylenia Cascone
2021 ◽  
Author(s):  
◽  
Brittany Grieve

<p>This thesis explored the impact of thermal insulation on the energy performance of New Zealand air-conditioned commercial office buildings. A sample of calibrated energy models constructed using real building performance data and construction information was used to ensure that the results produced were as realistic as possible to the actual building performance of New Zealand commercial office buildings. The aim was to assess how different climates and building attributes impact thermal insulation's ability to reduce energy consumption in New Zealand commercial office buildings.   Driven by the ever increasing demands for healthier, more comfortable, more sustainable buildings, building regulations have steadily increased the levels of insulation they require in new buildings over time. Improving the thermal properties of the building envelope with the addition of thermal insulation is normally used to reduce the amount of heating and cooling energy a building requires. Thermal insulation reduces the conductive heat transfer through the building envelope and with a higher level of thermal resistance, the less heat would transfer through the envelope. Consequently, the common expectation is that the addition of thermal insulation to the building envelope will always reduce energy consumption. However, this assumption is not always the case. For internal load dominated buildings located in certain climates, the presence of any or a higher level of thermal insulation may prevent heat loss through the wall, increasing the cooling energy required. This issue is thought to have not been directly examined in literature until 2008. However, an early study undertaken in New Zealand in 1996 found that for climates similar or warmer than Auckland, the addition of insulation could be detrimental to an office building's energy efficiency due to increased cooling energy requirements.  The energy performance of a sample of 13 real New Zealand office building energy models with varying levels of thermal insulation in 8 locations was examined under various scenarios. A parametric method of analysis using building energy modelling was used to assess the energy performance of the buildings. Buildings were modelled as built and standardised with the current NZS4243:2007 regulated and assumed internal load and operational values. The effect the cooling thermostat set point temperature had on the buildings' energy performance at varying levels of insulation was also tested.   The study concluded that the use of thermal insulation in New Zealand office buildings can cause an increase in cooling energy for certain types of buildings in any of the eight locations and thermal insulation levels explored in the study. The increase in cooling energy was significant enough to increase the total energy consumption of two buildings when modelled as built. These buildings were characterised by large internal loads, low performance windows with high window to wall ratios and low surface to volume ratios. The current minimum thermal resistance requirements were found to not be effective for a number of buildings in North Island locations.</p>


2021 ◽  
Author(s):  
◽  
Brittany Grieve

<p>This thesis explored the impact of thermal insulation on the energy performance of New Zealand air-conditioned commercial office buildings. A sample of calibrated energy models constructed using real building performance data and construction information was used to ensure that the results produced were as realistic as possible to the actual building performance of New Zealand commercial office buildings. The aim was to assess how different climates and building attributes impact thermal insulation's ability to reduce energy consumption in New Zealand commercial office buildings.   Driven by the ever increasing demands for healthier, more comfortable, more sustainable buildings, building regulations have steadily increased the levels of insulation they require in new buildings over time. Improving the thermal properties of the building envelope with the addition of thermal insulation is normally used to reduce the amount of heating and cooling energy a building requires. Thermal insulation reduces the conductive heat transfer through the building envelope and with a higher level of thermal resistance, the less heat would transfer through the envelope. Consequently, the common expectation is that the addition of thermal insulation to the building envelope will always reduce energy consumption. However, this assumption is not always the case. For internal load dominated buildings located in certain climates, the presence of any or a higher level of thermal insulation may prevent heat loss through the wall, increasing the cooling energy required. This issue is thought to have not been directly examined in literature until 2008. However, an early study undertaken in New Zealand in 1996 found that for climates similar or warmer than Auckland, the addition of insulation could be detrimental to an office building's energy efficiency due to increased cooling energy requirements.  The energy performance of a sample of 13 real New Zealand office building energy models with varying levels of thermal insulation in 8 locations was examined under various scenarios. A parametric method of analysis using building energy modelling was used to assess the energy performance of the buildings. Buildings were modelled as built and standardised with the current NZS4243:2007 regulated and assumed internal load and operational values. The effect the cooling thermostat set point temperature had on the buildings' energy performance at varying levels of insulation was also tested.   The study concluded that the use of thermal insulation in New Zealand office buildings can cause an increase in cooling energy for certain types of buildings in any of the eight locations and thermal insulation levels explored in the study. The increase in cooling energy was significant enough to increase the total energy consumption of two buildings when modelled as built. These buildings were characterised by large internal loads, low performance windows with high window to wall ratios and low surface to volume ratios. The current minimum thermal resistance requirements were found to not be effective for a number of buildings in North Island locations.</p>


2020 ◽  
pp. 50-64
Author(s):  
Kuladeep Kumar Sadevi ◽  
Avlokita Agrawal

With the rise in awareness of energy efficient buildings and adoption of mandatory energy conservation codes across the globe, significant change is being observed in the way the buildings are designed. With the launch of Energy Conservation Building Code (ECBC) in India, climate responsive designs and passive cooling techniques are being explored increasingly in building designs. Of all the building envelope components, roof surface has been identified as the most significant with respect to the heat gain due to the incident solar radiation on buildings, especially in tropical climatic conditions. Since ECBC specifies stringent U-Values for roof assembly, use of insulating materials is becoming popular. Along with insulation, the shading of the roof is also observed to be an important strategy for improving thermal performance of the building, especially in Warm and humid climatic conditions. This study intends to assess the impact of roof shading on building’s energy performance in comparison to that of exposed roof with insulation. A typical office building with specific geometry and schedules has been identified as base case model for this study. This building is simulated using energy modelling software ‘Design Builder’ with base case parameters as prescribed in ECBC. Further, the same building has been simulated parametrically adjusting the amount of roof insulation and roof shading simultaneously. The overall energy consumption and the envelope performance of the top floor are extracted for analysis. The results indicate that the roof shading is an effective passive cooling strategy for both naturally ventilated and air conditioned buildings in Warm and humid climates of India. It is also observed that a fully shaded roof outperforms the insulated roof as per ECBC prescription. Provision of shading over roof reduces the annual energy consumption of building in case of both insulated and uninsulated roofs. However, the impact is higher for uninsulated roofs (U-Value of 3.933 W/m2K), being 4.18% as compared to 0.59% for insulated roofs (U-Value of 0.33 W/m2K).While the general assumption is that roof insulation helps in reducing the energy consumption in tropical buildings, it is observed to be the other way when insulation is provided with roof shading. It is due to restricted heat loss during night.


Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2064
Author(s):  
Jin-Hee Kim ◽  
Seong-Koo Son ◽  
Gyeong-Seok Choi ◽  
Young-Tag Kim ◽  
Sung-Bum Kim ◽  
...  

Recently, there have been significant concerns regarding excessive energy use in office buildings with a large window-to-wall ratio (WWR) because of the curtain wall structure. However, prior research has confirmed that the impact of the window area on energy consumption varies depending on building size. A newly proposed window-to-floor ratio (WFR) correlates better with energy consumption in the building. In this paper, we derived the correlation by analyzing a simulation using EnergyPlus, and the results are as follows. In the case of small buildings, the results of this study showed that the WWR and energy requirement increase proportionally, and the smaller the size is, the higher the energy sensitivity will be. However, results also confirmed that this correlation was not established for buildings approximately 3600 m2 or larger. Nevertheless, from analyzing the correlation between the WFR and the energy requirements, it could be deduced that energy required increased proportionally when the WFR was 0.1 or higher. On the other hand, the correlation between WWR, U-value, solar heat gain coefficient (SHGC), and material property values of windows had little effect on energy when the WWR was 20%, and the highest effect was seen at a WWR of 100%. Further, with an SHGC below 0.3, the energy requirement decreased with an increasing WWR, regardless of U-value. In addition, we confirmed the need for in-depth research on the impact of the windows’ U-value, SHGC, and WWR, and this will be verified through future studies. In future studies on window performance, U-value, SHGC, visible light transmittance (VLT), wall U-value as sensitivity variables, and correlation between WFR and building size will be examined.


2018 ◽  
Vol 16 (1) ◽  
pp. 24-31
Author(s):  
Wasiska Iyati ◽  
◽  
Eryani Nurma Yulita ◽  
Jusuf Thojib ◽  
Heru Sufianto ◽  
...  

The narrow land in big cities such as Jakarta, increases the amount of high rise building, especially multi-storey office building. Office building consumes much energy to provide air conditioning to meet the thermal comfort inside the building. On the other hand, the building shape, building envelope, and building orientation to the sun's position are the main factors in building design aspects that affect the amount of cooling load. This study aims to investigate the impact of the aspect ratio or the ratio of the longer dimension of an oblong plan to the shorter, on external heat gain of multi-storey office building. Variables examined include the transparent and solid area of building envelope, the total area of the surface of the building envelope in any orientation, and the volume of the building, as well as the influence of those proportion on the external heat gain. This study uses mathematical calculations to predict the cooling load of the building, particularly external heat gain through the walls, roof and glass, as well as comparative analysis of models studied. The study also aims to generate the design criteria of building form and proportion of multi-storey office buildings envelope with lower external heat gain. In Jakarta climatic conditions, the result on rectangular building plan with aspect ratio of 1 to 4 shows that the external heat gain did not differ significantly, and the smallest heat gain is found on the aspect ratio of 1.8. Results also showed that the greater aspect ratio, the greater reduction of external heat gain obtained by changing the orientation of the longest side facing east-west into the north-south, about 2.79% up to 42.14% on the aspect ratio of 1.1 to 4. In addition, it is known that in same building volume, changing the number of floors from 10 to 50 can improve the external heat gain almost twice.


2014 ◽  
Vol 899 ◽  
pp. 62-65 ◽  
Author(s):  
Rastislav Ingeli ◽  
Boris Vavrovič ◽  
Miroslav Čekon

Energy demand reduction in buildings is an important measure to achieve climate change mitigation. It is essential to minimize heat losses in designing phase in accordance of building energy efficiency. For building energy efficiency in a mild climate zone, a large part of the heating demand is caused by transmission losses through the building envelope. Building envelopes with high thermal resistance are typical for low-energy buildings in general. In this sense thermal bridges impact increases by using of greater thickness of thermal insulation. This paper is focused on thermal bridges minimizing through typical system details in buildings. The impact of thermal bridges was studied by comparative calculations for a case study of building with different amounts of thermal insulation. The calculated results represent a percentage distribution of heat loss through typical building components in correlation of various thicknesses of their thermal insulations.


2014 ◽  
Vol 564 ◽  
pp. 315-320 ◽  
Author(s):  
Maatouk Khoukhi ◽  
Mahmoud Tahat

The impact of the thermal conductivity (k-value) change of polystyrene insulation material in building envelope due to changes in temperature on the thermal and energy performance of a typical residential building under hot climate is investigated. Indeed, the thermal and energy performance of buildings depends on the thermal characteristics of the building envelope, and particularly on the thermal resistance of the insulation material used. The thermal insulation material which is determined by its thermal conductivity, which describes the ability of heat to flow cross the material in presence of a gradient of temperature, is the main key to assess the performance of the thermal insulation material. When performing the energy analysis or calculating the cooling load for buildings, we use published values of thermal conductivity of insulation materials, which are normally evaluated at 24°C according to the ASTM standards. In reality, thermal insulation in building is exposed to significant and continuous temperature variations, due essentially to the change of outdoor air temperature and solar radiation. Many types of insulation materials are produced and used in Oman, but not enough information is available to evaluate their performance under the prevailing climatic condition. The main objective of this study is to investigate the relationship between the temperature and thermal conductivity of various densities of polystyrene, which is widely used as building insulation material in Oman. Moreover, the impact of thermal conductivity variation with temperature on the envelope-induced cooling load for a simple building model is discussed. This work will serve as a platform to investigate the effect of the operating temperature on thermal conductivity of other building material insulations, and leads to more accurate assessment of the thermal and energy performance of buildings in Oman.


2020 ◽  
Vol 20 (1) ◽  
pp. 24-34
Author(s):  
Farheen Bano ◽  
Vandana Sehgal

In this study, the energy consumption of three government and three private office buildings in Lucknow was investigated, and the energy performance index (EPI) for each building was determined. The main purpose of this research was to assess the energy usage of the buildings and identify factors affecting the energy usage. An analysis was performed using data from an energy audit of government buildings, electricity bills of private office buildings, and an on-site visit to determine building envelope materials and its systems. The annual energy consumption of buildings has been evaluated through EPI. The EPI, measured in kilowatt hour per square meter per year, is annual energy consumption in kilowatt hours divided by the gross floor area of the building in square meters. In this study, the energy benchmark for day-time-use office buildings in composite climate specified by Energy Conservation Building Code (ECBC) has been compared with the energy consumption of the selected buildings. Consequently, it has been found that the average EPI of the selected buildings was close to the national energy benchmark indicated by ECBC. Moreover, factors causing inefficient energy consumption were determined, and solutions for consistent energy savings are suggested for buildings in composite climate.


2019 ◽  
Vol 14 (4) ◽  
pp. 533-542
Author(s):  
Yuanda Hong ◽  
Wu Deng ◽  
Collins I Ezeh ◽  
Zhen Peng

Abstract Attaining sustainability in high-rise office buildings necessitates determining the major elements and their associating impacts on the energy performance of this building typology. This study investigates the impact of architectural and engineering features on the energy performance of high-rise office buildings within a warm-summer-cold-winter climate. A rectangular building plan form with a 1:1.44 plan ratio, vertical split core position and central atrium presented the best building performance. The plan form, core position and atrium effect accounted for 59, 30 and 11%, respectively, of an estimated 20.6% building energy savings. Furthermore, exploiting passive strategies founded on the climate and building features as defined by `PassivHaus’ standards further reduced the building energy usage.


2020 ◽  
Vol 10 (21) ◽  
pp. 7862
Author(s):  
Muhyiddine Jradi

When considering that over 80% of buildings in Denmark were built before the 1980′s, a holistic energy retrofitting of the existing building stock is a major milestone to attain the energy and environmental targets of the country. In this work, a case study of three public schools is considered for post-retrofit process evaluation. The three schools were heavily retrofitted by September 2018 with energy conservation and improvement measures that were implemented targeting both the building envelope and various energy systems. A technical evaluation of the energy retrofit process in the schools was carried out, when considering one year of operation after the completion of the retrofitting work. Actual data from the heating and electricity meters in the schools were collected and compared with the pre-retrofit design numbers which rely majorly on static tabulated numbers for savings evaluation. It was shown that the retrofit design numbers largely overestimate the attained savings, where the average performance gap between the expected and real numbers for the three schools is around 61% and 136% for annual heating and electricity savings, respectively. On the other hand, an alternative approach was proposed where calibrated dynamic energy performance models, which were developed for the three schools in EnergyPlus, were used to simulate the impact of implementing the retrofit measures. It was shown that implementing this approach could predict much better the impacts of the retrofit process with an average gap of around 17% for heating savings and 21% for electricity savings. Based on the post-retrofit process evaluation in the three schools, it was concluded that using dynamic model simulations has the potential of lowering the performance gap between the promised and real savings when compared to static tabulated approaches, although the savings are still generally over-estimated in both approaches.