Characterisation of CoNi(Cu)/Cu multilayers deposited from a citrate electrolyte in a flow channel cell

2004 ◽  
Vol 49 (12) ◽  
pp. 2041-2049 ◽  
Author(s):  
S.M.S.I. Dulal ◽  
E.A. Charles ◽  
S. Roy
Micromachines ◽  
2020 ◽  
Vol 11 (2) ◽  
pp. 177 ◽  
Author(s):  
Zengming Zhang ◽  
Shuhao Zhao ◽  
Fei Hu ◽  
Guangpu Yang ◽  
Juan Li ◽  
...  

The sensitive quantification of low-abundance nucleic acids holds importance for a range of clinical applications and biological studies. In this study, we describe a facile microfluidic chip for absolute DNA quantifications based on the digital loop-mediated isothermal amplification (digital LAMP) method. This microfluidic chip integrates a cross-flow channel for droplet generation with a micro-cavity for droplet tiling. DNA templates in the LAMP reagent were divided into ~20,000 water-in-oil droplets at the cross-flow channel. The droplets were then tiled in the micro-cavity for isothermal amplification and fluorescent detection. Different from the existing polydimethylsiloxane (PDMS) microfluidic chips, this study incorporates gold nanoparticles (AuNPs) into PDMS substrate through silica coating and dodecanol modification. The digital LAMP chip prepared by AuNPs-PDMS combines the benefits of the microstructure manufacturing performance of PDMS with the light-to-heat conversion advantages of AuNPs. Upon illumination with a near infrared (NIR) LED, the droplets were stably and efficiently heated by the AuNPs in PDMS. We further introduce an integrated device with a NIR heating unit and a fluorescent detection unit. The system could detect HBV (hepatitis B virus)-DNA at a concentration of 1 × 101 to 1 × 104 copies/μL. The LED-driven digital LAMP chip and the integrated device; therefore, demonstrate high accuracy and excellent performance for the absolute quantification of low-abundance nucleic acids, showing the advantages of integration, miniaturization, cost, and power consumption.


Mathematics ◽  
2021 ◽  
Vol 9 (16) ◽  
pp. 1860
Author(s):  
Eugene Talygin ◽  
Alexander Gorodkov

Previously, it has been shown that the dynamic geometric configuration of the flow channel of the left heart and aorta corresponds to the direction of the streamlines of swirling flow, which can be described using the exact solution of the Navier–Stokes and continuity equations for the class of centripetal swirling viscous fluid flows. In this paper, analytical expressions were obtained. They describe the functions C0t and Г0t, included in the solutions, for the velocity components of such a flow. These expressions make it possible to relate the values of these functions to dynamic changes in the geometry of the flow channel in which the swirling flow evolves. The obtained expressions allow the reconstruction of the dynamic velocity field of an unsteady potential swirling flow in a flow channel of arbitrary geometry. The proposed approach can be used as a theoretical method for correct numerical modeling of the blood flow in the heart chambers and large arteries, as well as for developing a mathematical model of blood circulation, considering the swirling structure of the blood flow.


Author(s):  
S. Sharafat ◽  
A. Aoyama ◽  
N. Morley ◽  
N. Ghoniem ◽  
B. Williams ◽  
...  
Keyword(s):  

2021 ◽  
Vol 172 ◽  
pp. 100-111
Author(s):  
Zhihong Zhao ◽  
Zihao Dou ◽  
Guihong Liu ◽  
Sicong Chen ◽  
Xianfeng Tan

2005 ◽  
Vol 128 (3) ◽  
pp. 585-598 ◽  
Author(s):  
Wei Shang ◽  
Robert W. Besant

A prime concern with the design of ultra-compact heat exchangers is the impact on performance of flow channel variations due to flow channel hydraulic diameter variations caused by manufacturing tolerances. This paper uses analytical methods to show that as the standard deviation in flow channel sizes, caused by manufacturing tolerances in a rotary regenerative exchanger, is increased compared to the average flow channel diameter the effective number of transfer units decreases. Depending on the operating conditions, the entropy generation number either increases or decreases with increasing flow channel size variations. These findings extend previous findings that showed that flow channel variations cause lower pressure drops and effectiveness.


Sign in / Sign up

Export Citation Format

Share Document