A computationally efficient numerical model for heat transfer simulation of deep borehole heat exchangers

2018 ◽  
Vol 167 ◽  
pp. 79-88 ◽  
Author(s):  
Liang Fang ◽  
Nairen Diao ◽  
Zhukun Shao ◽  
Ke Zhu ◽  
Zhaohong Fang
Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 754 ◽  
Author(s):  
Jiewen Deng ◽  
Qingpeng Wei ◽  
Shi He ◽  
Mei Liang ◽  
Hui Zhang

Deep borehole heat exchangers (DBHEs) extract heat from the medium-depth geothermal energy with the depth of 2–3 km and provide high-temperature heat source for the medium-depth geothermal heat pump systems (MD-GHPs). This paper focuses on the heat transfer performance of DBHEs, where field tests and simulation are conducted to analyze the heat transfer process and the influence factors. Results identify that the heat transfer performance is greatly influenced by geothermal properties of the ground, thermal properties and depth of DBHEs and operation parameters, which could be classified into external factors, internal factors and synergic adjustment. In addition, the long-term operation effects are analyzed with the simulation, results show that with inlet water temperature setting at 20 °C and flow rate setting at 6.0 kg/s, the average outlet water temperature only drops 0.99 °C and the average heat extraction drops 9.5% after 20-years operation. Therefore, it demonstrates that the medium-depth geothermal energy can serve as the high-temperature heat source for heat pump systems stably and reliably. The results from this study can be potentially used to guide the system design and optimization of DBHEs.


Baltica ◽  
2019 ◽  
Vol 31 (2) ◽  
pp. 146-153
Author(s):  
Audrius Indriulionis ◽  
Žygimantas Palaitis ◽  
Petras Šinkūnas ◽  
Robert Mokrik

The vertical borehole heat exchangers were surrounded by the heterogeneous multilayered geological environment and groundwater flow that affected the performance of borehole plants. In this paper, the field investigation of vertical borehole ground heat exchangers in capital city Vilnius (Visoriai), Lithuania is presented. The numerical heat transfer model considering seven different geological strata was developed using the cylindrical heat sink model for vertical borehole inside by solving the soil mass and heat transfer equations with groundwater flow. The numerical multilayered ground vertical borehole heat transfer model was calculated and validated by in-situ thermal response test data. The numerical model results were also compared with the homogeneous finite difference model expressed by the temperature response functions (well known as “g-functions”). The practical realization of g-functions was designed in the Earth Energy Designer as a practical tool for geoengineers designing the vertical borehole plants. The temperature profiles at borehole wall at different heating times were presented and explored together with relative errors. The numerical model will be used as a practical tool for the Lithuanian Geological Survey under the Ministry of Environment to estimate the underground conditions for the consumption of shallow geothermal energy.


Geothermics ◽  
2021 ◽  
Vol 96 ◽  
pp. 102220
Author(s):  
Wenke Zhang ◽  
Wenjing Li ◽  
Bjørn R Sørensen ◽  
Ping Cui ◽  
Yi Man ◽  
...  

2021 ◽  
Vol 237 ◽  
pp. 110794
Author(s):  
Wenke Zhang ◽  
Jianhua Wang ◽  
Fangfang Zhang ◽  
Wei Lu ◽  
Ping Cui ◽  
...  

2022 ◽  
Author(s):  
Kaiu Piipponen ◽  
Annu Martinkauppi ◽  
Sami Vallin ◽  
Teppo Arola ◽  
Nina Leppäharju ◽  
...  

Abstract The energy sector is undergoing a fundamental transformation, with significant investment in low-carbon technologies to replace fossil-based systems. In densely populated urban areas, deep boreholes offer an alternative over shallow geothermal systems, which demand extensive surface area to attain large-scale heat production. This paper presents numerical calculations of the thermal energy that can be extracted from the medium-deep borehole heat exchangers of depths ranging from 600-3000 m. We applied the thermogeological parameters of three locations across Finland and tested two types of coaxial borehole heat exchangers to understand better the variables that affect heat production in low permeability crystalline rocks. For each depth, location, and heat collector type, we used a range of fluid flow rates to examine the correlation between thermal energy production and resulting outlet temperature. Our results indicate a trade-off between thermal energy production and outlet fluid temperature depending on the fluid flow rate, and that the vacuum-insulated tubing outperforms high-density polyethylene pipe in energy and temperature production. In addition, the results suggest that the local thermogeological factors impact heat production. Maximum energy production from a 600-m-deep well achieved 170 MWh/a, increasing to 330 MWh/a from a 1000-m-deep well, 980 MWh/a from a 2-km-deep well, and up to 1880 MWh/a from a 3-km-deep well. We demonstrate that understanding the interplay of the local geology, heat exchanger materials, and fluid circulation rates is necessary to maximize the potential of medium-deep geothermal boreholes as a reliable long-term baseload energy source.


2010 ◽  
Vol 132 (11) ◽  
Author(s):  
M. J. White ◽  
G. F. Nellis ◽  
S. A. Klein ◽  
W. Zhu ◽  
Y. Gianchandani

Cryogenic and high-temperature systems often require compact heat exchangers with a high resistance to axial conduction in order to control the heat transfer induced by axial temperature differences. One attractive design for such applications is a perforated plate heat exchanger that utilizes high conductivity perforated plates to provide the stream-to-stream heat transfer and low conductivity spacers to prevent axial conduction between the perforated plates. This paper presents a numerical model of a perforated plate heat exchanger that accounts for axial conduction, external parasitic heat loads, variable fluid and material properties, and conduction to and from the ends of the heat exchanger. The numerical model is validated by experimentally testing several perforated plate heat exchangers that are fabricated using microelectromechanical systems based manufacturing methods. This type of heat exchanger was investigated for potential use in a cryosurgical probe. One of these heat exchangers included perforated plates with integrated platinum resistance thermometers. These plates provided in situ measurements of the internal temperature distribution in addition to the temperature, pressure, and flow rate measured at the inlet and exit ports of the device. The platinum wires were deposited between the fluid passages on the perforated plate and are used to measure the temperature at the interface between the wall material and the flowing fluid. The experimental testing demonstrates the ability of the numerical model to accurately predict both the overall performance and the internal temperature distribution of perforated plate heat exchangers over a range of geometry and operating conditions. The parameters that were varied include the axial length, temperature range, mass flow rate, and working fluid.


Sign in / Sign up

Export Citation Format

Share Document