Comparative analysis of heat transfer performance of coaxial pipe and U-type deep borehole heat exchangers

Geothermics ◽  
2021 ◽  
Vol 96 ◽  
pp. 102220
Author(s):  
Wenke Zhang ◽  
Wenjing Li ◽  
Bjørn R Sørensen ◽  
Ping Cui ◽  
Yi Man ◽  
...  
Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 754 ◽  
Author(s):  
Jiewen Deng ◽  
Qingpeng Wei ◽  
Shi He ◽  
Mei Liang ◽  
Hui Zhang

Deep borehole heat exchangers (DBHEs) extract heat from the medium-depth geothermal energy with the depth of 2–3 km and provide high-temperature heat source for the medium-depth geothermal heat pump systems (MD-GHPs). This paper focuses on the heat transfer performance of DBHEs, where field tests and simulation are conducted to analyze the heat transfer process and the influence factors. Results identify that the heat transfer performance is greatly influenced by geothermal properties of the ground, thermal properties and depth of DBHEs and operation parameters, which could be classified into external factors, internal factors and synergic adjustment. In addition, the long-term operation effects are analyzed with the simulation, results show that with inlet water temperature setting at 20 °C and flow rate setting at 6.0 kg/s, the average outlet water temperature only drops 0.99 °C and the average heat extraction drops 9.5% after 20-years operation. Therefore, it demonstrates that the medium-depth geothermal energy can serve as the high-temperature heat source for heat pump systems stably and reliably. The results from this study can be potentially used to guide the system design and optimization of DBHEs.


2013 ◽  
Vol 832 ◽  
pp. 160-165 ◽  
Author(s):  
Mohammad Alam Khairul ◽  
Rahman Saidur ◽  
Altab Hossain ◽  
Mohammad Abdul Alim ◽  
Islam Mohammed Mahbubul

Helically coiled heat exchangers are globally used in various industrial applications for their high heat transfer performance and compact size. Nanofluids can provide excellent thermal performance of this type of heat exchangers. In the present study, the effect of different nanofluids on the heat transfer performance in a helically coiled heat exchanger is examined. Four different types of nanofluids CuO/water, Al2O3/water, SiO2/water, and ZnO/water with volume fractions 1 vol.% to 4 vol.% was used throughout this analysis and volume flow rate was remained constant at 3 LPM. Results show that the heat transfer coefficient is high for higher particle volume concentration of CuO/water, Al2O3/water and ZnO/water nanofluids, while the values of the friction factor and pressure drop significantly increase with the increase of nanoparticle volume concentration. On the contrary, low heat transfer coefficient was found in higher concentration of SiO2/water nanofluids. The highest enhancement of heat transfer coefficient and lowest friction factor occurred for CuO/water nanofluids among the four nanofluids. However, highest friction factor and lowest heat transfer coefficient were found for SiO2/water nanofluids. The results reveal that, CuO/water nanofluids indicate significant heat transfer performance for helically coiled heat exchanger systems though this nanofluids exhibits higher pressure drop.


Author(s):  
F. Sun ◽  
H. Li ◽  
J. Drummond ◽  
G.-X. Wang

Bayonet tubes, simple refluent heat exchangers, are widely used to heat or cool a media when the heating/cooling agent is readily accessible from one side only. Many studies have been conducted to evaluate the heat transfer performance of bayonet tubes. The majority of these studies focus on the heat transfer in the annular section and little on the end surface. This paper presents a numerical simulation of the laminar flow and heat transfer in a bayonet tube. The simulation is first validated by the experimental data in the literature. The flow and heat transfer in bayonet tubes are then investigated with both flat and curved end surfaces. Both local and average Nusselt number on the end surfaces are calculated under various Re and geometry conditions. Effect of the end surface curvature is studied by comparing the performances of the flat and curved ended bayonet tubes.


Author(s):  
Raffaele L. Amalfi ◽  
Todd Salamon ◽  
Filippo Cataldo ◽  
Jackson B. Marcinichen ◽  
John R. Thome

Abstract The present study is focused on the experimental characterization of two-phase heat transfer performance and pressure drops within an ultra-compact heat exchanger (UCHE) suitable for electronics cooling applications. In this specific work, the UCHE prototype is anticipated to be a critical component for realizing a new passive two-phase cooling technology for high-power server racks, as it is more compact and lighter weight than conventional heat exchangers. This technology makes use of a novel combination of thermosyphon loops, at the server-level and rack-level, to passively cool an entire rack. In the proposed two-phase cooling technology, a smaller form factor UCHE is used to transfer heat from the server-level thermosyphon cooling loop to the rack-level thermosyphon cooling loop, while a larger form factor UCHE is used to reject the total heat from the server rack into the facility-level cooling loop. The UCHE is composed of a double-side-copper finned plate enclosed in a stainless steel enclosure. The geometry of the fins and channels on both sides are optimized to enhance the heat transfer performance and flow stability, while minimizing the pressure drops. These features make the UCHE the ideal component for thermosyphon cooling systems, where low pressure drops are required to achieve high passive flow circulation rates and thus achieve high critical heat flux values. The UCHE’s thermal-hydraulic performance is first evaluated in a pump-driven system at the Laboratory of Heat and Mass Transfer (LTCM-EPFL), where experiments include many configurations and operating conditions. Then, the UCHE is installed and tested as the condenser of a thermosyphon loop that rejects heat to a pumped refrigerant system at Nokia Bell Labs, in which both sides operate with refrigerants in phase change (condensation-to-boiling). Experimental results demonstrate high thermal performance with a maximum heat dissipation density of 5455 (kW/m3/K), which is significantly larger than conventional air-cooled heat exchangers and liquid-cooled small pressing depth brazed plate heat exchangers. Finally, a thermal performance analysis is presented that provides guidelines in terms of heat density dissipations at the server- and rack-level when using passive two-phase cooling.


Author(s):  
Bin Ren ◽  
Xiaoying Tang ◽  
Facai Ren ◽  
Jibing Wang ◽  
Bofeng Bai

Abstract Heat exchanger is a device that transfers heat between hot and cold fluids. Due to the different size and type, the actual heat transfer performance is usually not the same as the design value. Meanwhile, various heat exchangers using new types of heat transfer elements have emerged, bringing the difficulty to obtain the heat transfer performance by only theoretical calculation. Therefore, studying test methods and developing test standards for heat exchangers have become the research focus in many countries. In this paper, the basic principles of various performance test methods are firstly introduced, including Wilson plot method, equal Reynolds number method and nonlinear fitting method. Then the restrictions on the use of these methods and the factors affecting the test results are analyzed. Finally, the Chinese codes and standards of performance testing for heat exchangers are listed, including JB/T 10379-2002, GB/T 27698-2011 and TSG R0010-2019. The test methods used in GB/T 27698 are described in detail. The results show that GB 27698 mainly focus on the specification of testing systems and procedures and can test heat transfer performance of almost all types of heat exchangers in industry under different heat transfer modes. However, there are lack of formulas and methods for calculating uncertainty of testing results.


Sign in / Sign up

Export Citation Format

Share Document