Frequency thermal characteristic and parametric study of multi-functional building envelope for coolth recovery and thermal insulation: Modelling and experimental validation

2021 ◽  
pp. 111541
Author(s):  
Liao Li ◽  
Chong Zhang ◽  
Wenjie Gang ◽  
Jinbo Wang
2019 ◽  
Vol 13 (2) ◽  
pp. 129-133
Author(s):  
Gennadiy Farenyuk

The paper presents the basic methodical principles for the time analysis of the variations of envelope structures’ thermal insulation properties and for the substantiation of the thermal reliability criterion, which should allow the analysis of the actual parameters of heat losses during the operation of buildings. In the paper, the state of the envelope structures thermal failure, the concept of building thermal envelope thermal reliability and the principles of its rating are defined. The physical meaning and basic criterion of the envelope structure thermal reliability are formulated. The application of the thermal reliability criterion allows determining the probable variations in the thermal insulation properties during the building operation and, accordingly, the changes of the building energy performance over time.


Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6597
Author(s):  
Ahmet Bircan Atmaca ◽  
Gülay Zorer Gedik ◽  
Andreas Wagner

Mosques are quite different from other building types in terms of occupant type and usage schedule. For this reason, they should be evaluated differently from other building types in terms of thermal comfort and energy consumption. It is difficult and probably not even necessary to create homogeneous thermal comfort in mosques’ entire usage area, which has large volumes and various areas for different activities. Nevertheless, energy consumption should be at a minimum level. In order to ensure that mosques are minimally affected by outdoor climatic changes, the improvement of the properties of the building envelope should have the highest priority. These optimal properties of the building envelope have to be in line with thermal comfort in mosques. The proposed method will be a guide for designers and occupants in the design process of new mosques or the use of existing mosques. The effect of the thermal properties of the building envelope on energy consumption was investigated to ensure optimum energy consumption together with an acceptable thermal comfort level. For this purpose, a parametric simulation study of the mosques was conducted by varying optical and thermal properties of the building envelope for a temperature humid climate zone. The simulation results were analyzed and evaluated according to current standards, and an appropriate envelope was determined. The results show that thermal insulation improvements in the roof dome of buildings with a large volume contributed more to energy savings than in walls and foundations. The use of double or triple glazing in transparent areas is an issue that should be considered together with the solar energy gain factor. Additionally, an increasing thickness of thermal insulation in the building envelope contributed positively to energy savings. However, the energy savings rate decreased after a certain thickness. The proposed building envelope achieved a 33% energy savings compared to the base scenario.


Buildings ◽  
2019 ◽  
Vol 9 (12) ◽  
pp. 238 ◽  
Author(s):  
Stamoulis ◽  
Santos ◽  
Lenz ◽  
Tusset

The rational use of energy has motivated research on improving the energy efficiency of buildings, which are responsible for a large share of world consumption. A strategy to achieve this goal is the application of optimized thermal insulation on a building envelope to avoid thermal exchanges with the external environment, reducing the use of heating, ventilation and air-conditioning (HVAC) systems. In order to contribute to the best choice of insulation applied to an industrial shed roof, this study aims to provide an optimization tool to assist this process. Beyond the thermal comfort and cost of the insulation, some hygrothermic properties also have been analysed to obtain the best insulation option. To implement this optimization technique, several thermo-energetic simulations of an industrial shed were performed using the Domus software, applying 4 types of insulation material (polyurethane, expanded polystyrene, rockwool and glass wool) on the roof. Ten thicknesses ranging from 0.5 cm to 5 cm were considered, with the purpose of obtaining different thermal comfort indexes (PPD, predicted percentage dissatisfied). Posteriorly, the best insulation ranking has been obtained from the weights assigned to the parameters in the objective function, using the technique of the genetic algorithm (GA) applied to multi-criteria selection. The optimization results showed that polyurethane (PU) insulation, applied with a thickness of 1 cm was the best option for the roof, considering the building functional parameters, occupant metabolic activity, clothing insulation and climate conditions. On the other hand, when the Brazilian standard was utilized, rock wool (2 cm) was considered the best choice.


2018 ◽  
Vol 149 ◽  
pp. 02097
Author(s):  
LAMRANI Abdelghafour ◽  
SAFAR Said ◽  
ROUGUI Mohamed

In this work, we present a parametric study of a new administrative building, located in El-Ksar El Kebir region (Morocco). In order to have a building that complies with the RTCM in a technically and economically sound manner, we have carried out a number of interventions to insulate the components of the building, namely external walls, exposed roofs and openings. In this perspective, we have modelled the building envelope as a multi-zone building in TRNSYS and we have adopted an occupation scenario for this type of building. After determining the optimal insulation solutions, we simulated the administrative building in the five other thermal zones, to determine its feasibility in the latter.


Author(s):  
U. Desideri ◽  
S. Proietti ◽  
F. Zepparelli ◽  
P. Sdringola ◽  
E. Cenci

In the last twenty years, the exploitation of non-renewable resources and the effects of their applications on environment and human health were considered central topics in political and scientific debate on European and worldwide scale. This kind of resources have been used in different sectors, as energy systems, technological research, but also in private/public buildings and production of consumer goods, involving significantly domestic and ordinary life of every human being. Studies about the effect of this exploitation carried out discouraging results, in terms of climate changes and energy sustenance; this determined a progressive approach process to a new concept of development, able to couple the qualitative standard of modern life with the respect of planet and its inhabitants. Starting from this reflection, scientific community moved towards research on alternative resources and developed a new way to conceive planning process and technical innovations, in order to exploit renewable energies and recycled materials, promote energy savings and reduce environmental pollution. In this context the present paper aims at evaluating benefits relating to different solutions of thermal insulation in building envelope. In fact a high grade of insulation ensures better comfort conditions in inner spaces, reducing energy consumptions due to heating and cooling conditioning. The paper presents the results of a detailed Life Cycle Assessment (LCA) of the reflective foil ISOLIVING, conceived and produced by an Italian company. The Life Cycle Assessment methodology allows to consider all stages of the life cycle, from the extraction of raw materials to the product’s disposal, in an optics “from cradle to grave.” In particular, the study takes into account the production phase of the reflective foil ISOLIVING, the installation phase, the transport of all components to the production site and also the end of life scenario of the material. The possibility to collect many detailed information about the production phase adds value to the study. The analysis is carried out according to UNI EN ISO 14040 and UNI EN ISO 14044, which regulate the LCA procedure. The LCA modeling was performed using SimaPro software application. The results of the analysis allow to make an important comparison concerning the environmental performances, between the reflective foil ISOLIVING and other types of insulating materials.


2015 ◽  
Vol 107 ◽  
pp. 49-58 ◽  
Author(s):  
Xuan Cao ◽  
Junjie Liu ◽  
Xiaodong Cao ◽  
Qian Li ◽  
Eric Hu ◽  
...  

2014 ◽  
Vol 899 ◽  
pp. 62-65 ◽  
Author(s):  
Rastislav Ingeli ◽  
Boris Vavrovič ◽  
Miroslav Čekon

Energy demand reduction in buildings is an important measure to achieve climate change mitigation. It is essential to minimize heat losses in designing phase in accordance of building energy efficiency. For building energy efficiency in a mild climate zone, a large part of the heating demand is caused by transmission losses through the building envelope. Building envelopes with high thermal resistance are typical for low-energy buildings in general. In this sense thermal bridges impact increases by using of greater thickness of thermal insulation. This paper is focused on thermal bridges minimizing through typical system details in buildings. The impact of thermal bridges was studied by comparative calculations for a case study of building with different amounts of thermal insulation. The calculated results represent a percentage distribution of heat loss through typical building components in correlation of various thicknesses of their thermal insulations.