Thermo-economic analysis and multi-objective optimization of S-CO2 Brayton cycle waste heat recovery system for an ocean-going 9000 TEU container ship

2020 ◽  
Vol 221 ◽  
pp. 113077 ◽  
Author(s):  
Pengcheng Pan ◽  
Chengqing Yuan ◽  
Yuwei Sun ◽  
Xinping Yan ◽  
Mingjian Lu ◽  
...  
2013 ◽  
Author(s):  
Binyang Song ◽  
Weilin Zhuge ◽  
Xinqian Zheng ◽  
Yangjun Zhang ◽  
Yong Yin ◽  
...  

Energies ◽  
2020 ◽  
Vol 13 (1) ◽  
pp. 267 ◽  
Author(s):  
Guillermo Valencia Ochoa ◽  
Jhan Piero Rojas ◽  
Jorge Duarte Forero

This manuscript presents an advanced exergo-economic analysis of a waste heat recovery system based on the organic Rankine cycle from the exhaust gases of an internal combustion engine. Different operating conditions were established in order to find the exergy destroyed values in the components and the desegregation of them, as well as the rate of fuel exergy, product exergy, and loss exergy. The component with the highest exergy destroyed values was heat exchanger 1, which is a shell and tube equipment with the highest mean temperature difference in the thermal cycle. However, the values of the fuel cost rate (47.85 USD/GJ) and the product cost rate (197.65 USD/GJ) revealed the organic fluid pump (pump 2) as the device with the main thermo-economic opportunity of improvement, with an exergo-economic factor greater than 91%. In addition, the component with the highest investment costs was the heat exchanger 1 with a value of 2.769 USD/h, which means advanced exergo-economic analysis is a powerful method to identify the correct allocation of the irreversibility and highest cost, and the real potential for improvement is not linked to the interaction between components but to the same component being studied.


2013 ◽  
Vol 27 (6) ◽  
pp. 1721-1729 ◽  
Author(s):  
Binyang Song ◽  
Weilin Zhuge ◽  
Rongchao Zhao ◽  
Xinqian Zheng ◽  
Yangjun Zhang ◽  
...  

2019 ◽  
Vol 14 (1) ◽  
Author(s):  
Gunabal S

Waste heat recovery systems are used to recover the waste heat in all possible ways. It saves the energy and reduces the man power and materials. Heat pipes have the ability to improve the effectiveness of waste heat recovery system. The present investigation focuses to recover the heat from Heating, Ventilation, and Air Condition system (HVAC) with two different working fluids refrigerant(R410a) and nano refrigerant (R410a+Al2O3). Design of experiment was employed, to fix the number of trials. Fresh air temperature, flow rate of air, filling ratio and volume of nano particles are considered as factors. The effectiveness is considered as response. The results were analyzed using Response Surface Methodology


2021 ◽  
Vol 234 ◽  
pp. 113947
Author(s):  
Alexandre Persuhn Morawski ◽  
Leonardo Rodrigues de Araújo ◽  
Manuel Salazar Schiaffino ◽  
Renan Cristofori de Oliveira ◽  
André Chun ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document