Technico-economic assessment of a lead-acid battery bank for standalone photovoltaic power plant

2018 ◽  
Vol 19 ◽  
pp. 185-191 ◽  
Author(s):  
Amine El Fathi ◽  
Abdelkader Outzourhit
Energies ◽  
2019 ◽  
Vol 12 (12) ◽  
pp. 2237 ◽  
Author(s):  
Andrew Swingler ◽  
Jordan Torrealba

In this communication, the measured behaviour of a lead-acid battery bank within a stand-alone residential solar photovoltaic (PV)-genset-battery hybrid power system in Canada is presented and discussed. In order to capture rare field-based battery performance data, a newly commissioned lead-acid battery bank was equipped with a battery monitoring device capable of logging voltage, current, temperature and amp-hours every 30 s for the life of the battery. The measured data captures a severe loss of battery capacity due to a combination of short-term deep discharge and extended partial state of charge operation—conditions not unusual during winter season PV-genset-battery hybrid power system operation. Subsequent manual override of the system control set points to encourage gradual battery overcharge are shown to recover the lead-acid battery bank’s performance over the following three months. Limitations of the power conversion system’s battery management approach are discussed and a novel closed loop control system for improving lead-acid based PV-genset-battery hybrid system performance is rationalized and proposed for further research.


Author(s):  
Doudou Nanitamo Luta ◽  
Atanda K. Raji

Most African remote telecoms base stations are powered from diesel generators, however, these generators are losing attractiveness due to their less reliability in addition to high operational and maintenance costs. Over 65% of the loss of telecom services observed in remote areas are caused by outages resulting from diverse types of failures that these generators can suffer, on top of their impacts on the environment. As alternative, off-grid renewable energy systems are often employed in place of diesel generators due to their capability to provide reliable electricity at an acceptable cost. This study proposes an off-grid system based on PV generators and backup energy storage consisting of lithium-ion batteries as an extended solution for powering remote telecom base stations in Africa. Modelling and simulation is performed using Matlab/Simulink environment. The findings showed better characteristics of lithium-ion battery bank as compared to lead-acid unit; lithium-ion battery bank displayed higher initial current and voltage over lead-acid battery bank. Moreover, when, both battery banks reached 50 % of their state of charge, lithium-ion bank current was still higher than that of lead-acid bank. In the same vein, lithium-ion battery bank presented a slower discharge time than lead-acid battery bank on top higher values at 50 % and 70% state of charges. Lastly, the state of charge of the lead-acid battery at the end of the simulation was 50 %, while that of the lithium-ion battery bank was around 60 %.


Energies ◽  
2018 ◽  
Vol 11 (9) ◽  
pp. 2361 ◽  
Author(s):  
H. Ariza Chacón ◽  
Edison Banguero ◽  
Antonio Correcher ◽  
Ángel Pérez-Navarro ◽  
Francisco Morant

Accurate and efficient battery modeling is essential to maximize the performance of isolated energy systems and to extend battery lifetime. This paper proposes a battery model that represents the charging and discharging process of a lead-acid battery bank. This model is validated over real measures taken from a battery bank installed in a research center placed at “El Chocó”, Colombia. In order to fit the model, three optimization algorithms (particle swarm optimization, cuckoo search, and particle swarm optimization + perturbation) are implemented and compared, the last one being a new proposal. This research shows that the identified model is able to estimate real battery features, such as state of charge (SOC) and charging/discharging voltage. The comparison between simulations and real measures shows that the model is able to absorb reading problems, signal delays, and scaling errors. The approach we present can be implemented in other types of batteries, especially those used in stand-alone systems.


2017 ◽  
Vol 5 (1) ◽  
pp. 20-26 ◽  
Author(s):  
Gautam Rituraj ◽  
Brijesh Kumar Kushwaha ◽  
Praveen Kumar

In this paper, an experimental study is carried out while charging the sealed lead acid battery bank using a series-parallel (SP) compensated contactless power transfer (CPT) system. Constant current (CC) and constant voltage (CV) modes are used for charging the battery bank. An expression of optimum operating frequency is derived to maintain the maximum compensated coil efficiency throughout the load variation in charging process. An experimental setup of SP compensated CPT system is built for charging the battery bank. The variation of compensated coil efficiency and the load phase angle with respect to different operating frequencies in CC and CV modes is verified with the measurement. Based on the analysis, the control parameters are identified.


Sign in / Sign up

Export Citation Format

Share Document