Experimental investigation of the reliability of reception of ultrasound signals in fire conditions

2014 ◽  
Vol 66 ◽  
pp. 25-34 ◽  
Author(s):  
Horia-Nicolai L. Teodorescu ◽  
Victor P. Cojocaru
2017 ◽  
pp. 315-323
Author(s):  
U. Dolinar ◽  
A. Ogrin ◽  
I. Planinc ◽  
T. Hozjan

Fire Research ◽  
2016 ◽  
Author(s):  
Hélder D. Craveiro ◽  
João Paulo C. Rodrigues ◽  
Luís M. Laím

Cold-formed steel (CFS) profiles with a wide range of cross-section shapes are commonly used in building construction industry. Nowadays several cross-sections can be built using the available standard single sections (C, U, Σ, etc.), namely open built-up and closed built-up cross-sections. This paper reports an extensive experimental investigation on the behavior of single and built-up cold-formed steel columns at both ambient and simulated fire conditions considering the effect of restraint to thermal elongation. The buckling behavior, ultimate loads and failure modes, of different types of CFS columns at both ambient and simulated fire conditions with restraint to thermal elongation, are presented and compared. Regarding the buckling tests at ambient temperature it was observed that the use of built-up cross-sections ensures significantly higher values of buckling loads. Especially for the built-up cross-sections the failure modes were characterized by the interaction of individual buckling modes, namely flexural about the minor axis, distortional and local buckling. Regarding the fire tests, it is clear that the same levels of restraint used in the experimental investigation induce different rates in the generated restraining forces due to thermal elongation of the columns. Another conclusion that can be drawn from the results is that by increasing the level of restraint to thermal elongation the failure of the columns is controlled by the generated restraining forces, whereas for lower levels of restraint the temperature plays a more important role. Hence, higher levels of imposed restraint to thermal elongation will lead to higher values of generated restraining forces and eventually to lower values of critical temperature and time.


2016 ◽  
Vol 105 ◽  
pp. 579-588 ◽  
Author(s):  
Ali Nadjai ◽  
Klelia Petrou ◽  
Sanghoon Han ◽  
Faris Ali
Keyword(s):  
In Fire ◽  

2013 ◽  
Vol 62 ◽  
pp. 238-248 ◽  
Author(s):  
Nicola Tondini ◽  
Barbara Rossi ◽  
Jean-Marc Franssen

2007 ◽  
Vol 353-358 ◽  
pp. 2676-2680
Author(s):  
Xiu Shan Sun ◽  
Ying Hua Liu ◽  
Zhang Zhi Cen ◽  
Dong Ping Fang

In this paper, full-scale reinforced concrete slabs are analyzed under thermal-mechanical loads in fire conditions. The rectangular one-way slabs including a simply supported slab and a three-span continuous slab are concerned in the analysis. Finite element simulation is carried out by using the ABAQUS program to evaluate the non-uniform temperature distributions in thickness of the slabs and to analyze the deformation and stress redistribution of the slabs at elevated temperatures. Sequentially coupled thermal and structural analyses are performed to simulate the responses of the slabs in fire conditions. Deformation and strength of the slabs under thermal and mechanical loads are discussed. The numerical results are compared with the experimental ones and good agreements are observed. The analysis results show that the main reinforcement ratio has significant effects on the deformation and strength of the slabs at elevated temperatures and the three-span continuous slab has better performance of fire-resistance than the simply supported slab.


1999 ◽  
Vol 26 (2) ◽  
pp. 156-167 ◽  
Author(s):  
D I Nwosu ◽  
VKR Kodur

A state-of-the-art review of the behaviour of steel frame structures in fire is presented. Results from different studies indicate that the behaviour of a complete structure is different from that of a single structural member under fire conditions from the point of view of fire resistance. Earlier studies also show that analysis and design of steel structures against fire based on their overall behaviour could lead to a reduction or the elimination of applied fire protection to certain structural members. The effects of continuity, restraint conditions, and load ratio on the fire resistance of frame structures are discussed. The beneficial aspects derived from considering overall structural rather than single-member behaviour in fire are illustrated through the analysis on two one-bay, one-storey, unprotected steel portal frames, a column, and a beam. Also comparison is made between the performance of a beam with different end restraints in fire. Results from the analyses indicate that the fire resistance of a member is increased when it is considered as part of a structure compared with when it is considered as a single member.Key words: steel, frames, fire resistance, buckling, loads, overall structural behaviour.


Sign in / Sign up

Export Citation Format

Share Document