Reversed-phase/weak anion exchange magnetic mesoporous microspheres for removal of matrix effects in lipophilic marine biotoxins analysis by ultrahigh-performance liquid chromatography coupled to tandem mass spectrometry

2019 ◽  
Vol 294 ◽  
pp. 104-111 ◽  
Author(s):  
Fei Xu ◽  
Feng Liu ◽  
Chaozhan Wang ◽  
Yinmao Wei
Author(s):  
L. Pérez-Mayán ◽  
G. Castro ◽  
M. Ramil ◽  
R. Cela ◽  
I. Rodríguez

AbstractThe performance of two different analytical methodologies to investigate the presence of glyphosate (GLY) and aminomethylphosphonic acid (AMPA) residues in wine samples was evaluated. Transformation of compounds in their fluorene-9-methyloxycarbonyl derivatives permitted their separation under reversed-phase liquid chromatography with tandem mass spectrometry (LC–MS/MS) determination. Although the wine matrix severely impaired the efficiency of GLY derivatization, this drawback was solved using a molecularly imprinted sorbent for the previous, selective extraction of GLY and AMPA from wine. Alternatively, the use of a strong anionic exchange, polyvinyl alcohol-based LC column, turned to be the most effective alternative for direct determination of both compounds in diluted wine samples. The chromatographic behavior of this column and the magnitude of matrix effects observed during analysis of diluted wine samples were significantly affected by the composition of the mobile phase. Under final working conditions, this column permitted the separation of AMPA and the fungicide fosetyl (which shows common transitions in tandem MS/MS methods), it improved significantly the sample throughput versus extraction-derivatization-purification method, and it allowed the use of solvent-based calibration standards. Both analytical procedures provided similar limits of quantification (LOQs) for GLY (0.5–1.0 ng mL−1), while the multistep method was 8 times more sensitive to AMPA than the direct procedure. GLY residues stayed above method LOQs in 70% of the processed wines; however, concentrations measured in 95% of positive samples remained 100 times below the maximum residue limit (MRL) set for GLY in vinification grapes. Graphical abstract


Molecules ◽  
2021 ◽  
Vol 26 (8) ◽  
pp. 2123
Author(s):  
Luboš Fical ◽  
Maria Khalikova ◽  
Hana Kočová Vlčková ◽  
Ivona Lhotská ◽  
Zuzana Hadysová ◽  
...  

Two new ultra-high performance liquid chromatography (UHPLC) methods for analyzing 21 selected antivirals and their metabolites were optimized, including sample preparation step, LC separation conditions, and tandem mass spectrometry detection. Micro-solid phase extraction in pipette tips was used to extract antivirals from the biological material of Hanks balanced salt medium of pH 7.4 and 6.5. These media were used in experiments to evaluate the membrane transport of antiviral drugs. Challenging diversity of physicochemical properties was overcome using combined sorbent composed of C18 and ion exchange moiety, which finally allowed to cover the whole range of tested antivirals. For separation, reversed-phase (RP) chromatography and hydrophilic interaction liquid chromatography (HILIC), were optimized using extensive screening of stationary and mobile phase combinations. Optimized RP-UHPLC separation was carried out using BEH Shield RP18 stationary phase and gradient elution with 25 mmol/L formic acid in acetonitrile and in water. HILIC separation was accomplished with a Cortecs HILIC column and gradient elution with 25 mmol/L ammonium formate pH 3 and acetonitrile. Tandem mass spectrometry (MS/MS) conditions were optimized in both chromatographic modes, but obtained results revealed only a little difference in parameters of capillary voltage and cone voltage. While RP-UHPLC-MS/MS exhibited superior separation selectivity, HILIC-UHPLC-MS/MS has shown substantially higher sensitivity of two orders of magnitude for many compounds. Method validation results indicated that HILIC mode was more suitable for multianalyte methods. Despite better separation selectivity achieved in RP-UHPLC-MS/MS, the matrix effects were noticed while using both chromatographic modes leading to signal enhancement in RP and signal suppression in HILIC.


Sign in / Sign up

Export Citation Format

Share Document