Behavior of atrial ectopic beats before and after pulmonary vein isolation in patients with atrial fibrillation: A reduction in the number and arrhythmogenicity of ectopic firings

Heart Rhythm ◽  
2006 ◽  
Vol 3 (12) ◽  
pp. 1421-1427 ◽  
Author(s):  
Teiichi Yamane ◽  
Taro Date ◽  
Yasuko Kanzaki ◽  
Keiichi Inada ◽  
Seiichiro Matsuo ◽  
...  
EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
P Loh ◽  
MHA Groen ◽  
K Taha ◽  
FHM Wittkampf ◽  
PA Doevendans ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: Private company. Main funding source(s): Abbott Background Irreversible electroporation (IRE) is a promising new non-thermal ablation technology for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). First in human studies demonstrated the feasibility and safety of IRE PVI. Objective Further investigate the safety of IRE PVI. Methods Twenty patients with symptomatic AF underwent IRE PVI under conscious sedation. Oral anticoagulation was uninterrupted and heparin was administered to maintain activated clotting time at 300-350 seconds. Non-arcing, non-barotraumatic 6 ms, 200 J IRE applications were delivered via a custom non-steerable 8 F, 14-polar circular IRE ablation catheter with a variable hoop diameter (16-27 mm). Voltage mapping  of the left atrium and the PVs was performed before and after ablation with a conventional circular mapping catheter. For both catheters a single transseptal access (8 F introducer, Agilis NxTTM) was used. Adenosine testing was performed after a 30-minute waiting period. On day 1 after ablation, patients underwent esophagoscopy and brain MRI (DWI/FLAIR). If abnormalities were detected, examinations were repeated in due time. Results In 20 patients, all 80 PVs could be successfully isolated with a mean of 11,8 ± 1,4 IRE applications per patient. Average time from first to last IRE application was 22 ± 5 minutes, total procedure duration was 107 ± 13 minutes and total fluoroscopy time was 23 ± 5 minutes. One PV reconnection occurred during adenosine testing, re-isolation was achieved with 2 additional IRE pulses. No periprocedural complications were observed. Brain MRI on day 1 after ablation showed punctate asymptomatic lesions in 3/20 patients (15%). At follow-up MRI the lesion disappeared in 1 patient while in the other 2 patients 1 lesion persisted. Esophagoscopy on day 1 showed an asymptomatic esophageal lesion in 1/20 patients (5%), at repeat esophagoscopy on day 22 the lesion had resolved completely. Conclusion Acute electrical PV isolation could be achieved safely and rapidly by IRE ablation under conscious sedation in 20 patients with symptomatic AF. Acute silent cerebral lesions were detected in 3/20 patients (15%) and may be due to ablation or to changes of therapeutic and diagnostic catheters over a single transseptal access.


Circulation ◽  
2008 ◽  
Vol 118 (suppl_18) ◽  
Author(s):  
kiyotake Ishikawa ◽  
Yukihiko Yoshida ◽  
Sumio Morita ◽  
Kenji Furusawa ◽  
Noriyoshi Kanemura ◽  
...  

Background: Left atrium (LA) dilation plays an important role in development and persistence of atrial fibrillation (AF). Some cases show structural reverse remodeling of LA after catheter ablation of AF. The aim of this study was to assess the clinical significance of LA reverse remodeling. Method and Results: Echocardiographic data before and after ablation was obtained in 173 cases who underwent pulmonary vein isolation from January 2006 to April 2008 (74.0% men, 61.0±11 years old; paroxysmal AF 114, persistent AF 34, permanent AF 25). Mean atrial diameter before ablation was 39.0±6.1mm (paroxysmal 37.7±5.6mm, persistent 40.7±5.3mm, and permanent 43.0±6.8mm) and LA reverse remodeling was defined as 10% decrement of LA transverse diameter. Half of the cases were taking anti-arrhythmic drugs after ablation, and AF recurrence occurred in 16.8% (29/173) during mean follow up period of 8.5±6.3 months. Reverse remodeling of LA was seen in 34.1% (59/173) and AF recurrence rate in this group was 11.9% (7/59), whereas 19.3% (22/114) without reverse remodeling (P=0.29). However, limited in patients with LA diameter over 40mm (44.5%; 77/173), 3.2% (1/31) of AF recurrence was seen in those with reverse remodeling, while 21.7% (10/46) without reverse remodeling (P=0.04). LA reverse remodeling was observed significantly frequent in patients without history of hypertension(41.5% without hypertension vs 25.6% with hypertension, P=0.036). Conclusion: LA reverse remodeling after catheter ablation of AF in dilated LA patient is a simple and useful predictor for non-recurrence of AF. Hypertension could be a disturbance for LA reverse remodeling.


Diagnostics ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 38
Author(s):  
Philipp S. Lange ◽  
Natasa Mihailovic ◽  
Eliane Esser ◽  
Gerrit Frommeyer ◽  
Alicia J. Fischer ◽  
...  

Purpose: To evaluate retinal and optic nerve head (ONH) perfusion in patients with atrial fibrillation (AF) before and after catheter ablation of AF with pulmonary vein isolation (PVI). Methods: 34 eyes of 34 patients with AF and 35 eyes of 35 healthy subjects were included in this study. Flow density data were obtained using spectral-domain OCT-A (RTVue XR Avanti with AngioVue, Optovue, Inc, Fremont, California, USA). The data of the superficial and deep vascular layers of the macula and the ONH (radial peripapillary capillary network, RPC) before and after PVI were extracted and analysed. Results: The flow density in the superficial OCT-angiogram (whole en face) and the ONH (RPC) in patients with AF was significantly lower compared to healthy controls (OCT-A superficial: study group: 48.77 (45.19; 52.12)%; control group: 53.01 (50.00; 54.25)%; p < 0.001; ONH: study group: 51.82 (48.41; 54.03)%; control group: 56.00 (54.35; 57.70)%; p < 0.001;). The flow density in the ONH (RPC) improved significantly in the study group following PVI (before: 51.82 (48.41; 54.03)%; after: 52.49 (50.34; 55.62)%; p = 0.007). Conclusions: Patients with AF showed altered ocular perfusion as measured using OCTA when compared with healthy controls. Rhythm control using PVI significantly improved ocular perfusion as measured using OCT-A. Non-contact imaging using OCTA provides novel information about the central global microperfusion of patients with AF.


2019 ◽  
pp. 49-57 ◽  
Author(s):  
J. Vesela ◽  
P. Osmancik ◽  
D. Herman ◽  
R. Prochazkova

Pulmonary vein isolation (PVI) is the cornerstone in the treatment of patients with paroxysmal atrial fibrillation (PAF). Some research has suggested studies have shown that modification of ganglionated plexuses (GP), performed with PVI, could lead to even better outcomes. The aim of this study was to determine the effect of PVI on the autonomic system. Heart rate variability (HRV) was used as a marker of autonomic system activity. Twenty-six PAF patients underwent PVI (PVI group) and twenty patients underwent PVI plus a GP ablation (GP group). In each group, 5 min long ECG signals obtained before and after the electrophysiology EP study were analyzed. Time and frequency domain parameters were evaluated. Vagal responses during ablation were observed in 15 (58 %) patients in the PVI group and in 12 (60 %) patients in the GP group. The change in normalized power in the low frequency (LF) and in the LF/HF ratio, before and after ablation, was statistically significant in both groups (LF/HF 2.6+/-1.6 before vs. 1.4+/-1.7 after ablation in PVI group and LF/HF 3.3+/-2.6 before vs. 1.8+/-1.9 after ablation in the GP group). Relative to heart rate variability parameters, there were no differences between PVI and PVI + plus GP ablation.


Sign in / Sign up

Export Citation Format

Share Document