scholarly journals B-PO02-101 META-ANALYSIS COMPARING OUTCOMES OF HIGHER POWER SHORTER DURATION AND LOWER POWER LONGER DURATION RADIOFREQUENCY ABLATION FOR ATRIAL FIBRILLATION

Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S137-S138
Author(s):  
Dibbendhu Khanra ◽  
Abdul Hamid ◽  
Saurabh A. Deshpande ◽  
Ahmed Abdalla ◽  
Siddhartha Mohan Anindya Mukherjee ◽  
...  
Heart Rhythm ◽  
2015 ◽  
Vol 12 (9) ◽  
pp. 1990-1996 ◽  
Author(s):  
Muhammad R. Afzal ◽  
Jawaria Chatta ◽  
Anweshan Samanta ◽  
Salman Waheed ◽  
Morteza Mahmoudi ◽  
...  

2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Ali H. Hachem ◽  
Joseph E. Marine ◽  
Housam A. Tahboub ◽  
Sana Kamdar ◽  
Shaffi Kanjwal ◽  
...  

Background. Pulmonary vein isolation is commonly performed using radiofrequency energy with cryoablation gaining acceptance. We performed a meta-analysis of randomized controlled trials which compared radiofrequency versus cryoablation for patients with atrial fibrillation. Methods. A systematic search strategy identified both published and unpublished articles from inception to November 10, 2016, in multiple databases. The primary outcomes for this meta-analysis were long-term freedom from atrial fibrillation at 12-month follow-up and overall postoperative complication rates. For all included studies, the methodological quality was assessed through the Cochrane Collaboration’s tool for risk of bias. Results. A total of 247 articles were identified with eight being included in this review as they satisfied the prespecified inclusion criteria. Overall, there was no significant difference in freedom from atrial fibrillation at ≥12-month follow-up between those receiving cryoballoon and radiofrequency ablation, respectively (OR = 0.98, CI = 0.67–1.43, I2 = 56%, p=0.90). Additionally, the secondary outcomes of duration of ablation, fluoroscopy time, and ablation time failed to reach significance. Cryoballoon ablation had significantly greater odds of postoperative phrenic nerve injury at 12-month follow-up. Conclusions. Our meta-analysis suggests that cryoballoon ablation provides comparable benefits with regard to freedom from atrial fibrillation at medium-term follow-up, fluoroscopy time, ablation time, operative duration, and overall complication rate in comparison to radiofrequency ablation.


EP Europace ◽  
2020 ◽  
Vol 22 (10) ◽  
pp. 1487-1494 ◽  
Author(s):  
Katharina Schoene ◽  
Arash Arya ◽  
Friederike Grashoff ◽  
Helge Knopp ◽  
Alexander Weber ◽  
...  

Abstract Aims The aim of the study was to determine the incidence of oesophageal lesions after radiofrequency ablation (RFA) of atrial fibrillation (AF) with or without the use of oesophageal temperature probes. Methods and results Two hundred patients were prospectively randomized into two groups: the OPERA+ group underwent RFA using oesophageal probes (SensiTherm™); the OPERA− group received RFA using fixed energy levels of 25 W at the posterior wall without an oesophageal probe. All patients underwent post-interventional endoscopy and Holter-electrocardiogram after 6 months. (Clinical.Trials.gov: NCT03246594). One hundred patients were randomized in OPERA+ and 100 patients in OPERA−. The drop-out rate was 10%. In total, 18/180 (10%) patients developed endoscopically diagnosed oesophageal lesions (EDEL). There was no difference between the groups with 10/90 (11%) EDEL in OPERA+ vs. 8/90 (9%) in OPERA− (P = 0.62). Despite the higher power delivered at the posterior wall in OPERA+ [28 ± 4 vs. 25 ± 2 W (P = 0.001)], the average EDEL size was equal [5.7 ± 2.6 vs. 4.5 ± 1.7 mm (P = 0.38)]. The peak temperature did not correlate with EDEL size. During follow-up, no patient died. Only one patient in OPERA− required a specific therapy for treatment of the lesion. Cumulative AF recurrence after 6 (3–13) months was 28/87 (32%) vs. 34/88 (39%), P = 0.541. Conclusion This first randomized study demonstrates that intraoesophageal temperature monitoring using the SensiTherm™ probe does not affect the probability of developing EDEL. The peak temperature measured by the thermoprobe seems not to correlate with the incidence of EDEL. Empiric energy reduction at the posterior wall did not affect the efficacy of the procedure.