Heat transport of magnetized Newtonian nanoliquids in an annular space between porous vertical cylinders with discrete heat source

Author(s):  
Fateh Mebarek-Oudina ◽  
A. Aissa ◽  
B. Mahanthesh ◽  
Hakan F. Öztop
2015 ◽  
Vol 137 (2) ◽  
Author(s):  
Matthew R. Pearson ◽  
Jamal Seyed-Yagoobi

Heat pipes are well known as simple and effective heat transport devices, utilizing two-phase flow and the capillary phenomenon to remove heat. However, the generation of capillary pressure requires a wicking structure and the overall heat transport capacity of the heat pipe is generally limited by the amount of capillary pressure generation that the wicking structure can achieve. Therefore, to increase the heat transport capacity, the capillary phenomenon must be either augmented or replaced by some other pumping technique. Electrohydrodynamic (EHD) conduction pumping can be readily used to pump a thin film of a dielectric liquid along a surface, using electrodes that are embedded into the surface. In this study, two two-phase heat transport devices are created. The first device transports the heat in a linear direction. The second device transports the heat in a radial direction from a central heat source. The radial pumping configuration provides several advantages. Most notably, the heat source is wetted with fresh liquid from all directions, thereby reducing the amount of distance that must be travelled by the working fluid. The power required to operate the EHD conduction pumps is a trivial amount relative to the heat that is transported.


Mathematics ◽  
2022 ◽  
Vol 10 (2) ◽  
pp. 178
Author(s):  
Mohammed Alghaseb ◽  
Walid Hassen ◽  
Abdelhakim Mesloub ◽  
Lioua Kolsi

In this study, a 3D numerical study of free ventilated room equipped with a discrete heat source was performed using the Finite Volume Method (FVM). To ensure good ventilation, two parallel openings were created in the room. A suction opening was located at the bottom of the left wall and another opening was located at the top of the opposite wall; the heat source was placed at various positions in order to compare the heating efficiency. The effects of Rayleigh number (103 ≤ Ra ≤ 106) for six heater positions was studied. The results focus on the impact of these parameters on the particle trajectories, temperature fields and on the heat transfer inside the room. It was found that the position of the heater has a dramatic effect on the behavior and topography of the flow in the room. When the heat source was placed on the wall with the suction opening, two antagonistic behaviors were recorded: an improvement in heat transfer of about 31.6%, compared to the other positions, and a low Rayleigh number against 22% attenuation for high Ra values was noted.


Sign in / Sign up

Export Citation Format

Share Document