Supercritical carbon dioxide Taylor–Couette–Poiseuille flow heat transfer

Author(s):  
Phillip Swann ◽  
Ingo Jahn ◽  
Hugh Russell
Author(s):  
Prabu Surendran ◽  
Sahil Gupta ◽  
Tiberiu Preda ◽  
Igor Pioro

This paper presents a thorough analysis of ability of various heat transfer correlations to predict wall temperatures and Heat Transfer Coefficients (HTCs) against experiments on internal forced-convective heat transfer to supercritical carbon dioxide conducted by Koppel [1], He [2], Kim [3] and Bae [4]. It should be noted the Koppel dataset was taken from a paper which used the Koppel data but was not written by Koppel. All experiments were completed in bare tubes with diameters from 0.948 mm to 9 mm for horizontal and vertical configurations. The datasets contain a total of 1573 wall temperature points with pressures ranging from 7.58 to 9.59 MPa, mass fluxes of 400 to 1641 kg/m2s and heat fluxes from 20 to 225 kW/m2. The main objective of the study was to compare several correlations and select the best of them in predicting HTC and wall temperature values for supercritical carbon dioxide. This study will be beneficial for analyzing heat exchangers involving supercritical carbon dioxide, and for verifying scaling parameters between CO2 and other fluids. In addition, supercritical carbon dioxide’s use as a modeling fluid is necessary as the costs of experiments are lower than supercritical water. The datasets were compiled and calculations were performed to find HTCs and wall and bulk-fluid temperatures using existing correlations. Calculated results were compared with the experimental ones. The correlations used were Mokry et al. [5], Swenson et al. [6] and a set of new correlations presented in Gutpa et al. [7]. Statistical error calculations were performed are presented in the paper.


2012 ◽  
Vol 134 (8) ◽  
Author(s):  
Alan Kruizenga ◽  
Hongzhi Li ◽  
Mark Anderson ◽  
Michael Corradini

Competitive cycles must have a minimal initial cost and be inherently efficient. Currently, the supercritical carbon dioxide (S-CO2) Brayton cycle is under consideration for these very reasons. This paper examines one major challenge of the S-CO2 Brayton cycle: the complexity of heat exchanger design due to the vast change in thermophysical properties near a fluid’s critical point. Turbulent heat transfer experiments using carbon dioxide, with Reynolds numbers up to 100 K, were performed at pressures of 7.5–10.1 MPa, at temperatures spanning the pseudocritical temperature. The geometry employed nine semicircular, parallel channels to aide in the understanding of current printed circuit heat exchanger designs. Computational fluid dynamics was performed using FLUENT and compared to the experimental results. Existing correlations were compared, and predicted the data within 20% for pressures of 8.1 MPa and 10.2 MPa. However, near the critical pressure and temperature, heat transfer correlations tended to over predict the heat transfer behavior. It was found that FLUENT gave the best prediction of heat transfer results, provided meshing was at a y+ ∼ 1.


Energies ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1031 ◽  
Author(s):  
Lei Chai ◽  
Konstantinos M. Tsamos ◽  
Savvas A. Tassou

This paper investigates the thermohydraulic performance of finned-tube supercritical carbon dioxide (sCO2) gas coolers operating with refrigerant pressures near the critical point. A distributed modelling approach combined with the ε-NTU method has been developed for the simulation of the gas cooler. The heat transfer and pressure drop for each evenly divided segment are calculated using empirical correlations for Nusselt number and friction factor. The model was validated against test results and then used to investigate the influence of design and operating parameters on local and overall gas cooler performance. The results show that the refrigerant heat-transfer coefficient increases with decreasing temperature and reaches its maximum close to the pseudocritical temperature before beginning to decrease. The pressure drop increases along the flow direction with decreasing temperature. Overall performance results illustrate that higher refrigerant mass flow rate and decreasing finned-tube diameter lead to improved heat-transfer rates but also increased pressure drops. Design optimization of gas coolers should take into consideration their impact on overall refrigeration performance and life cycle cost. This is important in the drive to reduce the footprint of components, energy consumption, and environmental impacts of refrigeration and heat-pump systems. The present work provides practical guidance to the design of finned-tube gas coolers and can be used as the basis for the modelling of integrated sCO2 refrigeration and heat-pump systems.


Sign in / Sign up

Export Citation Format

Share Document