Simulation of membrane heat pump system performance for space cooling

2019 ◽  
Vol 99 ◽  
pp. 371-381 ◽  
Author(s):  
Ahmad A. Bukshaisha ◽  
Brian M. Fronk
2013 ◽  
Vol 732-733 ◽  
pp. 564-570 ◽  
Author(s):  
Ying Ning Hu ◽  
Ya Zhao Liu ◽  
Jun Lin ◽  
Yan Wang

A ground source heat pump system of combined office and residential buildings in hot summer and warm winter region is introduced. The system performance is studied through the experiment, and the performance of underground heat balance is analyzed by TRNSYS. The results show the superiority and applicability of the ground source heat pump system.


2019 ◽  
Vol 111 ◽  
pp. 01076 ◽  
Author(s):  
Mingzhe Liu ◽  
Ryozo Ooka ◽  
Toshiyuki Hino ◽  
Ke Wen ◽  
Wonjun Choi ◽  
...  

We herein report the development of a distributed heat pump system that can utilize a variety of renewable energy sources to meet different building heating and cooling demands (i.e., a multiple source and multiple use heat pump system, MMHP). In this system, a water circulating loop is used to connect ground heat exchangers, a unique sky-source heat pump, and various heat pumps for heating and cooling purposes to form a thermal network within a building. This distribution increases the flexibility of the system and allows an improved matching of supply and demand. To evaluate the system performance, an experimental house was constructed, and a winter field experiment was conducted. We found that the reported heat pump for floor heating achieved a stable operation with a high coefficient of performance of ~11.5, while the heat collecting operation performance of the sky-source heat pump varied significantly depending on the amount of solar radiation and the outside air temperature. Finally, since the sky-source heat pump contributes to an improvement in the whole system performance, it appears that there is still room for improved regarding the whole system performance by adjusting the operating and control strategy.


2017 ◽  
Vol 143 ◽  
pp. 131-136 ◽  
Author(s):  
Qunli Zhang ◽  
Zhiming Wang ◽  
Chaohui Yin ◽  
Qian Nie ◽  
Liwen Jin

Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 554
Author(s):  
Hongkyo Kim ◽  
Yujin Nam ◽  
Sangmu Bae ◽  
Jae Sang Choi ◽  
Sang Bum Kim

A ground source heat pump system is one of the high-efficient technologies for space heating and cooling since it uses stable underground temperature. However, in actual application, many situations cannot be achieved due to the unsuitable design of operation. In particular, the design characteristics of buildings with different building load patterns are not reflected by the conventional design method. Moreover, the design capacity of the heat pump can be reduced by designing less capacity than the peak load through the introduction of the heat storage tank, but there is no related quantitative design method. Therefore, in this study, the effect of the ground source heat pump system design factors such as shape, length of the ground heat exchanger, and the capacity of the heat storage tank on the system performance was analyzed. To quantify the effect of such factors on system performance, an experimental plant was constructed and case studies were conducted for each design factor.


Sign in / Sign up

Export Citation Format

Share Document