Novel adhesive anchoring system through engineered adhesive-concrete interface

Structures ◽  
2021 ◽  
Vol 33 ◽  
pp. 947-956
Author(s):  
Hua Liu ◽  
Jian Zhao ◽  
Todd Davis
Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1154
Author(s):  
Dario De Domenico ◽  
Antonino Quattrocchi ◽  
Damiano Alizzio ◽  
Roberto Montanini ◽  
Santi Urso ◽  
...  

Digital Image Correlation (DIC) provides measurements without disturbing the specimen, which is a major advantage over contact methods. Additionally, DIC techniques provide full-field maps of response quantities like strains and displacements, unlike traditional methods that are limited to a local investigation. In this work, an experimental application of DIC is presented to investigate a problem of relevant interest in the civil engineering field, namely the interface behavior between externally bonded fabric reinforced cementitious mortar (FRCM) sheets and concrete substrate. This represents a widespread strengthening technique of existing reinforced concrete structures, but its effectiveness is strongly related to the bond behavior between composite fabric and underlying concrete. To investigate this phenomenon, a set of notched concrete beams are realized, reinforced with FRCM sheets on the bottom face, subsequently cured in different environmental conditions (humidity and temperature) and finally tested up to failure under three-point bending. Mechanical tests are carried out vis-à-vis DIC measurements using two distinct cameras simultaneously, one focused on the concrete front face and another focused on the FRCM-concrete interface. This experimental setup makes it possible to interpret the mechanical behavior and failure mode of the specimens not only from a traditional macroscopic viewpoint but also under a local perspective concerning the evolution of the strain distribution at the FRCM-concrete interface obtained by DIC in the pre- and postcracking phase.


2021 ◽  
Vol 238 ◽  
pp. 112211
Author(s):  
Jin Xia ◽  
Kuang-yi Shan ◽  
Xiao-hui Wu ◽  
Run-li Gan ◽  
Wei-liang Jin

2012 ◽  
Vol 64 (3) ◽  
pp. 185-194 ◽  
Author(s):  
V. L'Hostis ◽  
E. Amblard ◽  
W. Guillot ◽  
C. Paris ◽  
L. Bellot-Gurlet

2009 ◽  
Vol 7 (3) ◽  
pp. 425-438 ◽  
Author(s):  
Dawei Zhang ◽  
Hitoshi Furuuchi ◽  
Akihiro Hori ◽  
Tamon Ueda

2011 ◽  
Vol 47 (5) ◽  
pp. 529-538 ◽  
Author(s):  
D. Y. Cho ◽  
S. K. Park ◽  
S. N. Hong

2013 ◽  
Vol 687 ◽  
pp. 118-123 ◽  
Author(s):  
Oliver Weichold ◽  
Udo Antons

The effect of incorporating elastomeric domains in concrete is described from the point of fracture mechanics. Concrete is subject to brittle failure, since cracks propagate at an enormous speed in the crystalline matrix. However, micro cracks are attracted to volume elements with lower elastic moduli such as elastomeric domains. Cracks that encounter the concrete-elastomer interface are stopped since energy is dissipated by plastic deformation of and/or crack deflection by the elastomer. The domain size and the distribution of the elastomer as well as, and properties of the elastomer-concrete interface are crucial parameters. Such a combination differs substantially from previously prepared polymer-impregnated concretes, in which only glassy polymers were used.


2008 ◽  
Vol 35 (3) ◽  
pp. 312-320 ◽  
Author(s):  
A. Zaidi ◽  
R. Masmoudi

The difference between the transverse coefficients of thermal expansion of fiber reinforced polymer (FRP) bars and concrete generates radial pressure at the FRP bar – concrete interface, which induces tensile stresses within the concrete under temperature increase and, eventually, failure of the concrete cover if the confining action of concrete is insufficient. This paper presents the results of an experimental study to investigate the thermal effect on the behaviour of FRP bars and concrete cover, using concrete slab specimens reinforced with glass FRP bars and subjected to thermal loading from –30 to +80 °C. The experimental results show that failure of concrete cover was produced at temperatures varying between +50 and +60 °C for slabs having a ratio of concrete cover thickness to FRP bar diameter (c/db) less than or equal to 1.4. A ratio of c/db greater than or equal to 1.6 seems to be sufficient to avoid splitting failure of concrete cover for concrete slabs subjected to high temperatures up to +80 °C. Also, the first cracks appear in concrete at the FRP bar – concrete interface at temperatures around +40 °C. Comparison between experimental and analytical results in terms of thermal loads and thermal strains is presented.


Sign in / Sign up

Export Citation Format

Share Document