Crossover of liquid products from electrochemical CO2 reduction through gas diffusion electrode and anion exchange membrane

2020 ◽  
Vol 385 ◽  
pp. 140-145 ◽  
Author(s):  
Jie Zhang ◽  
Wen Luo ◽  
Andreas Züttel
Catalysts ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 482
Author(s):  
Hilmar Guzmán ◽  
Federica Zammillo ◽  
Daniela Roldán ◽  
Camilla Galletti ◽  
Nunzio Russo ◽  
...  

Electrochemical CO2 reduction is a promising carbon capture and utilisation technology. Herein, a continuous flow gas diffusion electrode (GDE)-cell configuration has been studied to convert CO2 via electrochemical reduction under atmospheric conditions. To this purpose, Cu-based electrocatalysts immobilised on a porous and conductive GDE have been tested. Many system variables have been evaluated to find the most promising conditions able to lead to increased production of CO2 reduction liquid products, specifically: applied potentials, catalyst loading, Nafion content, KHCO3 electrolyte concentration, and the presence of metal oxides, like ZnO or/and Al2O3. In particular, the CO productivity increased at the lowest Nafion content of 15%, leading to syngas with an H2/CO ratio of ~1. Meanwhile, at the highest Nafion content (45%), C2+ products formation has been increased, and the CO selectivity has been decreased by 80%. The reported results revealed that the liquid crossover through the GDE highly impacts CO2 diffusion to the catalyst active sites, thus reducing the CO2 conversion efficiency. Through mathematical modelling, it has been confirmed that the increase of the local pH, coupled to the electrode-wetting, promotes the formation of bicarbonate species that deactivate the catalysts surface, hindering the mechanisms for the C2+ liquid products generation. These results want to shine the spotlight on kinetics and transport limitations, shifting the focus from catalytic activity of materials to other involved factors.


2014 ◽  
Vol 35 (7) ◽  
pp. 1091-1097 ◽  
Author(s):  
Donglei Yang ◽  
Hongmei Yu ◽  
Guangfu Li ◽  
Wei Song ◽  
Yanxi Liu ◽  
...  

Processes ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 718
Author(s):  
Van Men Truong ◽  
Ngoc Bich Duong ◽  
Hsiharng Yang

Gas diffusion layers (GDLs) play a critical role in anion exchange membrane fuel cell (AEMFC) water management. In this work, the effect of GDL thickness on the cell performance of the AEMFC was experimentally investigated. Three GDLs with different thicknesses of 120, 260, and 310 µm (denoted as GDL-120, GDL-260, and GDL-310, respectively) were prepared and tested in a single H2/O2 AEMFC. The experimental results showed that the GDL-260 employed in both anode and cathode electrodes exhibited the best cell performance. There was a small difference in cell performance for GDL-260 and GDL-310, while water flooding was observed in the case of using GDL-120 operated at current densities greater than 1100 mA cm−2. In addition, it was found that the GDL thickness had more sensitivity to the AEMFC performance as used in the anode electrode rather than in the cathode electrode, indicating that water removal at the anode was more challenging than water supply at the cathode. The strategy of water management in the anode should be different from that in the cathode. These findings can provide a further understanding of the role of GDLs in the water management of AEMFCs.


2020 ◽  
Vol 8 (18) ◽  
pp. 9032-9038 ◽  
Author(s):  
Jinkyu Lim ◽  
Phil Woong Kang ◽  
Sun Seo Jeon ◽  
Hyunjoo Lee

Productivity of formates from electrochemical CO2 reduction was enhanced by using a Sn catalyst with dense tips electrodeposited on a gas diffusion electrode.


2021 ◽  
Author(s):  
Shima Alinejad ◽  
Jonathan Quinson ◽  
Yao Li ◽  
Ying Kong ◽  
Sven Reichenberger ◽  
...  

The lack of a robust and standardized experimental test bed to investigate the performance of catalyst materials for the electrochemical CO2 reduction reaction (ECO2RR) is one of the major challenges in this field of research. To best reproduce and mimic commercially relevant conditions for catalyst screening and testing, gas diffusion electrode (GDE) setups attract a rising attention as an alternative to conventional aqueous-based setups such as the H-cell configuration. In particular a zero-gap design shows promising features for upscaling to the commercial scale. In this study, we develop further our recently introduced zero-gap GDE setup for the CO2RR using an Au electrocatalyst as model system and identify/report the key experimental parameters to control in the catalyst layer preparation in order to optimize the activity and selectivity of the catalyst.


Materials ◽  
2019 ◽  
Vol 12 (13) ◽  
pp. 2048
Author(s):  
Van Men Truong ◽  
Ngoc Bich Duong ◽  
Chih-Liang Wang ◽  
Hsiharng Yang

The performance of an anion exchange membrane fuel cell (AEMFC) under various operating conditions, including cell temperature and humidification of inlet gases, was systematically investigated in this study. The experimental results indicate that the power density of an AEMFC is susceptible to the cell temperature and inlet gas humidification. A high performance AEMFC can be achieved by elevating the cell operating temperature along with the optimization of the gas feed dew points at the anode and cathode. As excess inlet gas humidification at the anode is supplied, the flooding is less severe at a higher cell temperature because the water transport in the gas diffusion substrate by evaporation is more effective upon operation at a higher cell temperature. The cell performance is slightly affected when the humidification at the anode is inadequate, owing to dehydration of the membrane, especially at a higher cell temperature. Furthermore, the cell performance in conditions of under-humidification or over-humidification at the cathode is greatly reduced at the different cell temperatures tested due to the dehydration of the anion exchange membrane and the water shortage or oxygen mass transport limitations, respectively, for the oxygen reduction reaction. In addition, back diffusion could partly support the water demand at the cathode once a water concentration gradient between the anode and cathode is formed. These results, in which sophisticated water management was achieved, can provide useful information regarding the development of high-performance AEMFC systems.


Sign in / Sign up

Export Citation Format

Share Document