Effects of water/polymer friction coefficient and polymer moduli on drug release from polyelectrolyte hydrogel carriers

2015 ◽  
Vol 213 ◽  
pp. e144 ◽  
Author(s):  
Yabo Liu ◽  
Yihan Xu ◽  
Pang Zhu ◽  
Yuxi Jia
2017 ◽  
Vol 68 (10) ◽  
pp. 2346-2349
Author(s):  
Magdalena Birsan ◽  
Nela Bibire ◽  
Madalina Vieriu ◽  
Alina Diana Panainte ◽  
Ileana Cojocaru

Original pharmaceutical formulations have been produced as oral biomucoadhesive tablets for antifungal medication. They have been obtained through direct compression using as matrix forming polymers various sorts of hydroxypropyl methylcellulose. The main goal of the study was determining the swelling index of the new mucobioadhesive formulations with miconazole nitrate in order to correctly evaluate the time of contact with mucosa, and the prolongation of drug release. For each formulation, the flowing parameters have been determined: flowing time, friction coefficient, repose angle, Haussner ratio, Carr index, and the swelling index for 6 formulations containing various sorts of hydroxypropyl methylcellulose as matrix molders, while the formulation variables studied were time and association ratio between those polymers. Though results analysis, we noticed that the values of the swelling index depended on the type and quantity of polymer, results that could also be explained by the proportionality relationship to flowing and compressibility parameters.


2017 ◽  
Vol 66 (11) ◽  
pp. 1662-1668 ◽  
Author(s):  
Hui Ye ◽  
Yabo Liu ◽  
Linlin Gao ◽  
Tianxiang Du ◽  
Yuxi Jia

2017 ◽  
Vol 2 (3) ◽  

Melanoma is the most dangerous type of skin cancer in which mostly damaged unpaired DNA starts mutating abnormally and staged an unprecedented proliferation of epithelial skin to form a malignant tumor. In epidemics of skin, pigment-forming melanocytes of basal cells start depleting and form uneven black or brown moles. Melanoma can further spread all over the body parts and could become hard to detect. In USA Melanoma kills an estimated 10,130 people annually. This challenge can be succumbed by using the certain anti-cancer drug. In this study design, cyclophosphamide were used as a model drug. But it has own limitation like mild to moderate use may cause severe cytopenia, hemorrhagic cystitis, neutropenia, alopecia and GI disturbance. This is a promising challenge, which is caused due to the increasing in plasma drug concentration above therapeutic level and due to no rate limiting steps involved in formulation design. In this study, we tried to modify drug release up to threefold and extended the release of drug by preparing and designing niosome based topical gel. In the presence of Dichloromethane, Span60 and cholesterol, the initial niosomes were prepared using vacuum evaporator. The optimum percentage drug entrapment efficacy, zeta potential, particle size was found to be 72.16%, 6.19mV, 1.67µm.Prepared niosomes were further characterized using TEM analyzer. The optimum batch of niosomes was selected and incorporated into topical gel preparation. Cold inversion method and Poloxamer -188 and HPMC as core polymers, were used to prepare cyclophosphamide niosome based topical gel. The formula was designed using Design expert 7.0.0 software and Box-Behnken Design model was selected. Almost all the evaluation parameters were studied and reported. The MTT shows good % cell growth inhibition by prepared niosome based gel against of A375 cell line. The drug release was extended up to 20th hours. Further as per ICH Q1A (R2), guideline 6 month stability studies were performed. The results were satisfactory and indicating a good formulation approach design was achieved for Melanoma treatment.


2012 ◽  
Vol 1 (8) ◽  
pp. 186 ◽  
Author(s):  
Urmi Das ◽  
Mohammad Salim Hossain

<p>Sustained release Carvedilol matrix tablets constituting Kollidon SR were developed in this study in an attempt to investigate the effect of release modifiers on the release profile of Carvedilol from matrix. Three matrix tablet formulations were prepared by direct compression of Kollidon SR in combination with release modifier (HPMC and Microcrystalline Cellulose) and magnesium stearate. Tablets containing only Kollidon SR with the active ingredient demonstrated a rapid rate of drug release. Incorporation of HPMC in the matrix tablet prolonged the release of drug but incorporation of Microcrystalline Cellulose showed superimposable release pattern with an initial burst effect as confirmed by mean dissolution time and Higuchi release rate data. After 7 hours of dissolution, Carvedilol release from the matrix systems were 91.42%, 83.41%, from formulation F1 and F2 respectively. Formulation F3 exhibited 100 % release at 4 hours. All the tablet formulations showed acceptable pharmaco-technical properties and complied with the in-house specifications for tablet weight variation, friability, hardness, thickness, and diameter. Prepared tablets also showed sustained release property for carvedilol. The drug release mechanism from the matrix tablets of F1 and F2 was found to be followed by Fickian and F3 by Non-Fickian mechanism.</p><p>DOI: <a href="http://dx.doi.org/10.3329/icpj.v1i8.11095">http://dx.doi.org/10.3329/icpj.v1i8.11095</a></p> <p>International Current Pharmaceutical Journal 2012, 1(8): 186-192</p>


1985 ◽  
Vol 55 ◽  
Author(s):  
J-P. Hirvonen ◽  
M. Nastasi ◽  
J. R. Phillips ◽  
J. W. Mayer

ABSTRACTMultilayered samples of Ti-Pd with linearly varying compositions were irradiated by Xe ions at 600 keV. The induced microstructures were studied by using transmission electron microscopy and Rutherford backscattering. Mixing was found to be complete over the entire composition range, resulting in amorphous or amorphous plus crystalline structures except at the palladium-rich end, where a crystalline Pd-Ti solid solution was obtained. This is consistent with the high equilibrium solubility of Ti in Pd. In addition, significant coarsening of the microstructure caused by irradiation was found in this solid solution region.Friction measurements were carried out in air and water by using a polytetrafluoroethylene pin as a counterpart. In air the friction coefficient was independent of composition and microstructure after about 2000 passes. In water, however, after 600 passes the friction coefficient reached a steady-state value with a pronounced minimum over the amorphous region. This property was unchanged throughout the remaining 10000 passes.


Sign in / Sign up

Export Citation Format

Share Document