Catanionic mixed micellar cloud point extraction of metal ions in coal fly ash samples and their determination by CS-ETAAS

2019 ◽  
Vol 7 (3) ◽  
pp. 103119 ◽  
Author(s):  
Ravi Kumar K. ◽  
Shyamala P.
2010 ◽  
Vol 7 (4) ◽  
pp. 1200-1205 ◽  
Author(s):  
Parag Solanki ◽  
Vikal Gupta ◽  
Ruchi Kulshrestha

Coal fly ash was used to synthesize X-type zeolite by alkali fusion followed by hydrothermal treatment. Characteristics of the various Fly ash samples were carried out. Coal proximate analysis was done. Batch experiment was carried out for the adsorption of some heavy metal ions on to synthesized Zeolite. The cost of synthesized zeolite was estimated to be almost one-fifth of that of commercial 13X zeolite available in the market.


2020 ◽  
Vol 5 (3) ◽  
pp. 1193-1198
Author(s):  
Henilkumar M. Lankapati ◽  
Dharmesh R. Lathiya ◽  
Lalita Choudhary ◽  
Ajay K. Dalai ◽  
Kalpana C. Maheria

Talanta ◽  
2013 ◽  
Vol 110 ◽  
pp. 202-228 ◽  
Author(s):  
K. Pytlakowska ◽  
V. Kozik ◽  
M. Dabioch

Author(s):  
Ambreen Shah ◽  
Fayyaz Ahmed Keerio ◽  
Saima Qayyum Memon ◽  
Ghulam Zuhra Memon

A new method of cloud point extraction was determined for preconcentration and determination of different metal ions like copper(II), nickel(II) and cobalt(II) ions. The complexation has been done by bis(2-acetyl pyridine 4-phenyl 3-thiosemicarbazone) (APPT) using sodium dodecyl sulphate (SDS) as surfactant. Metal ions are extracted into the phase rich in SDS after centrifugation. Initially, micellar phase was dissolved in 10 mL of deionized water then acidified with 0.5 mol/L HNO3, enhanced the surfactant- rich phase and analyzed by flame atomic absorption spectrometry (FAAS). The effects of pH, the concen- trations of metal ions and chelating agent (APPT), volume of surfactant (SDS), equilibration temperature and time were studied on CPE. The preconcentration factor obtained was 25 and the limits of detection(DL) obtained for cobalt(II), nickel(II) and copper(II) were 1.5, 1.7 and 2.4 ng/mL, respectively. This method of preconcentration was effectively useful for the determination of cobalt(II), nickel(II) and copper(II) in water samples.


2017 ◽  
Vol 56 (6) ◽  
pp. 1461-1470 ◽  
Author(s):  
Subhajit Dash ◽  
Haribandhu Chaudhuri ◽  
Radha Gupta ◽  
Udayabhanu G. Nair ◽  
Ashis Sarkar

2013 ◽  
Vol 91 (12) ◽  
pp. 1219-1224 ◽  
Author(s):  
Wael I. Mortada ◽  
Al-Ahmad Z. Ali ◽  
Mohamed M. Hassanien

A simple and rapid cloud point extraction methodology has been developed for the separation and preconcentration of palladium (Pd2+), gold (Au3+), and silver (Ag+) ions. The metal ions in the initial aqueous solution were complexed with 4-allylthiosemicarbazide, and Triton X-114 was added as surfactant. Dilution of the surfactant-rich phase with acidified metanol was performed after phase separation, and the metal ions were determined by graphite furnace atomic absorption spectrometry. The main factors affecting the cloud point extraction procedure, such as pH, concentration of the ligand, amount of Triton X-114, equilibrium temperature, and incubation time, were investigated and optimized. Under the optimum experimental, the calibration graphs were linear upto 100 μg L−1 for Pd2+ and Au3+ and up to 80 μg L−1 for Ag+. The enrichment factors were 48, 53, and 51 for Pd2+, Au3+, and Ag+, respectively. The limits of detection, based on three times the standard deviation of the blank signal by seven replicate measurements, were 0.15, 0.07, and 0.04 μg L−1 for Pd2+, Au3+, and Ag+, respectively. The accuracy of the results was verified by analyzing spiked real samples (water, blood, and urine) as well as by comparison the results of geological samples with those obtained by ICP−MS after solvent extraction using ammonium pyrrolidinedithiocarbamate in methyl isobutyl ketone. The proposed method has been applied for the determination of the metal ions in real samples with satisfactory results.


Sign in / Sign up

Export Citation Format

Share Document