scholarly journals Sensitivity of the shear wave speed-stress relationship to soft tissue material properties and fiber alignment

Author(s):  
Jonathon L. Blank ◽  
Darryl G. Thelen ◽  
Matthew S. Allen ◽  
Joshua D. Roth
2021 ◽  
Author(s):  
Jonathon Blank ◽  
Darryl Thelen ◽  
Matthew S. Allen ◽  
Joshua Roth

The use of shear wave propagation to noninvasively gauge material properties and loading in tendons and ligaments is a growing area of interest in biomechanics. Prior models and experiments suggest that shear wave speed primarily depends on the apparent shear modulus (i.e., shear modulus accounting for contributions from all constituents) at low loads, and then increases with axial stress when axially loaded. However, differences in the magnitudes of shear wave speeds between ligaments and tendons, which have different substructures, suggest that the tissue’s composition and fiber alignment may also affect shear wave propagation. Accordingly, the objectives of this study were to (1) characterize changes in the apparent shear modulus induced by variations in constitutive properties and fiber alignment, and (2) determine the sensitivity of the shear wave speed-stress relationship to variations in constitutive properties and fiber alignment. To enable systematic variations of both constitutive properties and fiber alignment, we developed a finite element model that represented an isotropic ground matrix with an embedded fiber distribution. Using this model, we performed dynamic simulations of shear wave propagation at axial strains from 0% to 10%. We characterized the shear wave speed-stress relationship using a simple linear regression between shear wave speed squared and axial stress, which is based on an analytical relationship derived from a tensioned beam model. We found that predicted shear wave speeds were both in-range with shear wave speeds in previous in vivo and ex vivo studies, and strongly correlated with the axial stress (R2 = 0.99). The slope of the squared shear wave speed-axial stress relationship was highly sensitive to changes in tissue density. Both the intercept of this relationship and the apparent shear modulus were sensitive to both the shear modulus of the ground matrix and the stiffness of the fibers’ toe-region when the fibers were less well-aligned to the loading direction. We also determined that the tensioned beam model overpredicted the axial tissue stress with increasing load when the model had less well-aligned fibers. This indicates that the shear wave speed increases likely in response to a load-dependent increase in the apparent shear modulus. Our findings suggest that researchers may need to consider both the material and structural properties (i.e., fiber alignment) of tendon and ligament when measuring shear wave speeds in pathological tissues or tissues with less well-aligned fibers.


2021 ◽  
Vol 0 (0) ◽  
pp. 0-0
Author(s):  
Naiara Korta Martiartu ◽  
Dominik Nakhostin ◽  
Lisa Ruby ◽  
Thomas Frauenfelder ◽  
Marga B. Rominger ◽  
...  

2020 ◽  
pp. 193229682096525
Author(s):  
Roozbeh Naemi ◽  
Stefano E. Romero Gutierrez ◽  
David Allan ◽  
Gilmer Flores ◽  
Juvenal Ormaechea ◽  
...  

Introduction: The purpose of this study was to investigate the association between the mechanical properties of plantar soft tissue and diabetes status. Method: 51 (M/F: 21/30) participants with prediabetes onset (fasting blood sugar [FBS] level > 100 mg/dL), age >18 years, and no lower limb amputation were recruited after ethical approval was granted from Pontificia Universidad Catolica del Peru ethical review board. Ultrasound reverberant shear wave elastography was used to assess the soft tissue stiffness at the 1st metatarsal head (MTH), 3rd MTH, and the heel at both feet. Results: Spearman’s rank-order correlation (rho) test indicated a significant ( P < .05) positive correlations between FBS level and the plantar soft tissue shear wave speed at the 1st MTH: rho = 0.402 (@400 Hz), rho = 0.373 (@450 Hz), rho = 0.474 (@500 Hz), rho= 0.395 (@550 Hz), and rho = 0.326 (@600 Hz) in the left foot and rho = 0.364 (@450 Hz) in the right foot. Mann-Whitney U test indicated a significantly ( P < .05) higher shear wave speed in the plantar soft tissue with the following effect sizes (r) at the 1st MTH of the left foot at all tested frequencies: r = 0.297 (@450 Hz), r = 0.345 (@500 Hz), r = 0.322 (@550 Hz), and r = 0.275 (@600 Hz), and at the 1st MTH of right foot r = 0.286 (@400 Hz) in diabetes as compared with the age and body mass index matched prediabetes group. Conclusion: An association between fasting blood sugar level and the stiffness of the plantar soft tissue with higher values of shear wave speed in diabetes versus prediabetes group was observed. This indicated that the proposed approach can improve the assessment of the severity of diabetic foot complications with potential implications in patient stratification.


2014 ◽  
Vol 47 (11) ◽  
pp. 2685-2692 ◽  
Author(s):  
Ryan J. DeWall ◽  
Laura C. Slane ◽  
Kenneth S. Lee ◽  
Darryl G. Thelen

2003 ◽  
Vol 81 (1-2) ◽  
pp. 47-53 ◽  
Author(s):  
M B Helgerud ◽  
W F Waite ◽  
S H Kirby ◽  
A Nur

We report on compressional- and shear-wave-speed measurements made on compacted polycrystalline sI methane and sII methane–ethane hydrate. The gas hydrate samples are synthesized directly in the measurement apparatus by warming granulated ice to 17°C in the presence of a clathrate-forming gas at high pressure (methane for sI, 90.2% methane, 9.8% ethane for sII). Porosity is eliminated after hydrate synthesis by compacting the sample in the synthesis pressure vessel between a hydraulic ram and a fixed end-plug, both containing shear-wave transducers. Wave-speed measurements are made between –20 and 15°C and 0 to 105 MPa applied piston pressure. PACS No.: 61.60Lj


Choonpa Igaku ◽  
2021 ◽  
Author(s):  
Hiroko IIJIMA ◽  
Toshifumi TADA ◽  
Hiroyuki HACHIYA ◽  
Takashi NISHIMURA ◽  
Junko NISHIMURA ◽  
...  

2018 ◽  
Vol 46 (5) ◽  
pp. 489-501 ◽  
Author(s):  
Edgar Hernandez-Andrade ◽  
Eli Maymon ◽  
Suchaya Luewan ◽  
Gaurav Bhatti ◽  
Mohammad Mehrmohammadi ◽  
...  

AbstractObjective:To determine whether a soft cervix identified by shear-wave elastography between 18 and 24 weeks of gestation is associated with increased frequency of spontaneous preterm delivery (sPTD).Materials and methods:This prospective cohort study included 628 consecutive women with a singleton pregnancy. Cervical length (mm) and softness [shear-wave speed: (SWS) meters per second (m/s)] of the internal cervical os were measured at 18–24 weeks of gestation. Frequency of sPTD <37 (sPTD<37) and <34 (sPTD<34) weeks of gestation was compared among women with and without a short (≤25 mm) and/or a soft cervix (SWS <25thpercentile).Results:There were 31/628 (4.9%) sPTD<37 and 12/628 (1.9%) sPTD<34 deliveries. The combination of a soft and a short cervix increased the risk of sPTD<37 by 18-fold [relative risk (RR) 18.0 (95% confidence interval [CI], 7.7–43.9); P<0.0001] and the risk of sPTD<34 by 120-fold [RR 120.0 (95% CI 12.3–1009.9); P<0.0001] compared to women with normal cervical length. A soft-only cervix increased the risk of sPTD<37 by 4.5-fold [RR 4.5 (95% CI 2.1–9.8); P=0.0002] and of sPTD<34 by 21-fold [RR 21.0 (95% CI 2.6–169.3); P=0.0003] compared to a non-soft cervix.Conclusions:A soft cervix at 18–24 weeks of gestation increases the risk of sPTD <37 and <34 weeks of gestation independently of cervical length.


Sign in / Sign up

Export Citation Format

Share Document