Angular dependence of FMR resonance field for an infinite 2D-hexagonal array of ellipsoid chains

2021 ◽  
Vol 519 ◽  
pp. 167512
Author(s):  
R. Peña-Garcia ◽  
C.J.S. Machado Filho ◽  
E. Padrón-Hernández
2012 ◽  
Vol 190 ◽  
pp. 93-96
Author(s):  
I.O. Dzhun ◽  
N.G. Chechenin ◽  
S.A. Dushenko ◽  
E.A. Konstantinova

By measuring the angular dependence of ferromagnetic resonance field at room and low temperatures, it is demonstrated that the magnitude of magnetic field applied during magnetron deposition of Ta/F/AF/Ta structures, where F=Co, NiFe and AF=FeMn and IrMn, influences the uniaxial and unidirectional anisotropy, magnetization and the exchange bias blocking temperature. The deposition field effects on the bilayer structure are compared with the effects on a similar structure, but without antiferromagnetic layer. The exchange bias blocking temperature of investigated structures is found to be significantly lower than the Néel temperature of a bulk antiferromagnet. The origin of the observed effects is shortly discussed.


1976 ◽  
Vol 18 (11-12) ◽  
pp. 1443-1446 ◽  
Author(s):  
Y. Yang ◽  
N.L. Huang Liu ◽  
R. Orbach

2019 ◽  
Vol 10 ◽  
pp. 1-3 ◽  
Author(s):  
Yuset Guerra Davila ◽  
Frederico Alves Revoredo Junior ◽  
Ramon Pena-Garcia ◽  
Eduardo Padron-Hernandez

2017 ◽  
Author(s):  
Bo Tian ◽  
Peter Svedlindh ◽  
Mattias Strömberg ◽  
Erik Wetterskog

In this work, we demonstrate for the first time, a ferromagnetic resonance (FMR) based homogeneous and volumetric biosensor for magnetic label detection. Two different isothermal amplification methods, <i>i.e.</i>, rolling circle amplification (RCA) and loop-mediated isothermal amplification (LAMP) are adopted and combined with a standard electron paramagnetic resonance (EPR) spectrometer for FMR biosensing. For RCA-based FMR biosensor, binding of RCA products of a synthetic Vibrio cholerae target DNA sequence gives rise to the formation of aggregates of magnetic nanoparticles. Immobilization of nanoparticles within the aggregates leads to a decrease of the net anisotropy of the system and a concomitant increase of the resonance field. A limit of detection of 1 pM is obtained with an average coefficient of variation of 0.16%, which is superior to the performance of other reported RCA-based magnetic biosensors. For LAMP-based sensing, a synthetic Zika virus target oligonucleotide is amplified and detected in 20% serum samples. Immobilization of magnetic nanoparticles is induced by their co-precipitation with Mg<sub>2</sub>P<sub>2</sub>O<sub>7</sub> (a by-product of LAMP) and provides a detection sensitivity of 100 aM. The fast measurement, high sensitivity and miniaturization potential of the proposed FMR biosensing technology makes it a promising candidate for designing future point-of-care devices.<br>


2007 ◽  
Author(s):  
Alexander C. Barrie ◽  
Bryan S. Taylor ◽  
Jared M. Ekholm ◽  
Jr Hargus ◽  
William A.

2019 ◽  
Vol 28 (2) ◽  
pp. 111-121 ◽  
Author(s):  
Chia‐Yuan Chen ◽  
Ting‐Yang Kuo ◽  
Chien‐Wu Huang ◽  
Zih‐Hong Jian ◽  
Po‐Tsung Hsiao ◽  
...  

Materials ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3449
Author(s):  
Ireneusz Stefaniuk ◽  
Werner Obermayr ◽  
Volodymyr D. Popovych ◽  
Bogumił Cieniek ◽  
Iwona Rogalska

In this paper, we show a simple method of producing ferromagnetic materials with a Curie temperature above room temperature. The electron paramagnetic resonance (EPR) spectra of Cd1−xCrxTe (0.002 < x < 0.08) were measured with a dependence on temperature (82 K < T < 381 K). Obtained EPR lines were fitted to a Lorentz-shaped curve. The temperature dependencies of the parameters of the EPR lines, such as the peak-to-peak linewidth (Hpp), the intensity (A), as well as the resonance field (Hr), were studied. Ferromagnetism was noticed in samples at high temperatures (near room temperature). For a sample with a nominal concentration of chrome of x = 0.05, a very strong intrinsic magnetic field is observed. The value of the effective gyromagnetic factor for this sample is ge = 30 at T = 240 K. An increase of chrome concentration above x = 0.05 reduces the ferromagnetic properties considerably. Analysis of the temperature dependencies of the integral intensity of EPR spectra was carried out using the Curie–Weiss law and the paramagnetic Curie temperature was obtained.


Sign in / Sign up

Export Citation Format

Share Document