angular dependence
Recently Published Documents


TOTAL DOCUMENTS

2026
(FIVE YEARS 95)

H-INDEX

69
(FIVE YEARS 3)

2022 ◽  
Vol 192 ◽  
pp. 107973
Author(s):  
Luis Nahmad–Rohen ◽  
Misha Vorobyev

Author(s):  
Kakeru Tojo ◽  
Akira NAGAKUBO ◽  
Hirotsugu OGI

Abstract The dynamics of magnetization is important in spintronics, where the coupling between phonon and magnon attracts much attention. In this work, we study the angular dependence of the coupling between longitudinal-wave phonon and magnon. We investigated the magnetization dynamics using the time-resolved magneto-optical Kerr effect, which allows measuring spin-wave resonances and the magnetic echo signal. The frequency, mode number, and amplitude of the spin-wave resonance change with the out-of-plane angle of the external magnetic field. The amplitude of the magnetic echo signal caused by the strain pulse also changes with the angle. We calculate these angular dependences based on the Landau-Lifshitz-Gilbert equation and find that the angles of the external field and magnetic moment are important factors for the phonon-magnon coupling when phonon propagates in the thickness direction under the out-of-plane magnetic field.


2021 ◽  
Vol 13 (4) ◽  
pp. 479-486
Author(s):  
Gennady A. Ovsyannikov ◽  
◽  
Karen Y. Constantinian ◽  
Vladislav A. Shmakov ◽  
Anton V. Shadrin ◽  
...  

Kotelnikov Institute of Radioengineering and Electronics of Russian Academy of Sciences The paper presents the results of fabrication and structural study of SrIrO3/La0.7Sr0.3MnO3 heterostructures. The results of experimental studies of the spin current arising in the regime of ferromagnetic resonance are presented. The spin-orbit interaction present in 5d-oxides of transition metals, which is SrIrO3, provides an effective conversion of spin current to charge current due to the inverse spin Hall effect. The angular dependence of spin magnetoresistance makes it possible to determine the angle of the spin Hall effect.


Sensors ◽  
2021 ◽  
Vol 22 (1) ◽  
pp. 90
Author(s):  
Clément Devic ◽  
Johann Plagnard ◽  
Mélodie Munier

For technical and radioprotection reasons, it has become essential to develop new dosimetric tools adapted to the specificities of computed tomography (CT) to ensure precise and efficient dosimetry since the current standards are not suitable for clinical use and for new CT technological evolution. Thanks to its many advantages, plastic scintillating fibers (PSF) is a good candidate for more accurate and personalized real-time dosimetry in computed tomography, and the company Fibermetrix has developed a new device named IVISCAN® based on this technology. In this study, we evaluated performances of IVISCAN® and associated uncertainties in terms of dose-rate dependence, angular dependence, stability with cumulative dose, repeatability, energy dependence, length dependence, and special uniformity in reference and clinical computed tomography beam qualities. For repeatability, the standard deviation is less than 0.039%, and the absolute uncertainty of repeatability lies between 0.017% and 0.025%. The deviation between IVISCAN® and the reference regarding energy dependence is less than 1.88% in clinical use. Dose rate dependence results show a maximum deviation under ±2%. Angular dependence standard deviation σ is 0.8%, and the absolute uncertainty was 1.6%. We observed 1% of variation every 50 Gy steps up to a cumulative dose of 500 Gy. Probe response was found to be independent of the PSF length with a maximum deviation < 2.7% between the IVISCAN® probe and the 1 cm PSF probe. The presented results demonstrated that IVISCAN® performances are in accordance with metrology references and the international standard IEC61674 relative to dosemeters used in X-ray diagnostic imaging and then make it an ideal candidate for real-time dosimetry in CT applications.


2021 ◽  
Author(s):  
Yudie Huang ◽  
Fanzhou Lv ◽  
Jiaxu Chen ◽  
Shijia He ◽  
Zhihang Wang ◽  
...  

Abstract Structural color has been studied through various methods due to its distinguished features of stability, durability, high information storage density and high integration. However, the artificial structural color samples do not exhibit superior performance in color saturation and low angular dependence. Here, we present an approach to acquire additive reflective color based on a metal-dielectric-metal (MDM) stack. The upper layer composed of Ag particles is perforated in a hexagonal arrangement which profits from the dielectric anodic aluminum oxide (AAO) membrane, the size and shape of the Ag particles are getting inhomogeneous as the deposition thickness of the upper layer increasing, which expands the desired absorption range of surface plasmons. The residual non-anodized Al foil serves as a highly reflective substrate for efficient color presenting through the thin-film interference in this plasmonic MDM system. As a result, the color gamut area of this MDM stack is extended 8 times in CIE chromaticity coordinates. Finally, a wafer-scale (diameter of 83 mm) badge of Harbin Engineering University (HEU) with highly saturated colors and a pattern characterized with low angle-dependent property (up to 60°) are presented, which exhibit promising prospects in commercial coloring and imaging.


Author(s):  
D.S. Neznakhin ◽  
A.S. Bolyachkin ◽  
M.I. Bartashevich ◽  
L.V.B. Diop ◽  
O. Gutfleisch ◽  
...  

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
F. Holzmeier ◽  
J. Joseph ◽  
J. C. Houver ◽  
M. Lebech ◽  
D. Dowek ◽  
...  

AbstractCharacterizing time delays in molecular photoionization as a function of the ejected electron emission direction relative to the orientation of the molecule and the light polarization axis provides unprecedented insights into the attosecond dynamics induced by extreme ultraviolet or X-ray one-photon absorption, including the role of electronic correlation and continuum resonant states. Here, we report completely resolved experimental and computational angular dependence of single-photon ionization delays in NO molecules across a shape resonance, relying on synchrotron radiation and time-independent ab initio calculations. The angle-dependent time delay variations of few hundreds of attoseconds, resulting from the interference of the resonant and non-resonant contributions to the dynamics of the ejected electron, are well described using a multichannel Fano model where the time delay of the resonant component is angle-independent. Comparing these results with the same resonance computed in e-NO+ scattering highlights the connection of photoionization delays with Wigner scattering time delays.


Nanomaterials ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 3247
Author(s):  
Lina Grineviciute ◽  
Soon Hock Ng ◽  
Molong Han ◽  
Tania Moein ◽  
Vijayakumar Anand ◽  
...  

Polarisation analysis in the mid-infrared fingerprint region was carried out on thin (∼1 μm) Si and SiO2 films evaporated via glancing angle deposition (GLAD) method at 70∘ to the normal. Synchrotron-based infrared microspectroscopic measurements were carried out on the Infrared Microspectroscopy (IRM) beamline at Australian Synchrotron. Specific absorption bands, particularly Si-O-Si stretching vibration, was found to follow the angular dependence of ∼cos2θ, consistent with the absorption anisotropy. This unexpected anisotropy stems from the enhanced absorption in nano-crevices, which have orientation following the cos2θ angular dependence as revealed by Fourier transforming the image of the surface of 3D columnar films and numerical modeling of light field enhancement by sub-wavelength nano-crevices.


2021 ◽  
Vol 13 (23) ◽  
pp. 4771
Author(s):  
Karolina Trzcinska ◽  
Jaroslaw Tegowski ◽  
Pawel Pocwiardowski ◽  
Lukasz Janowski ◽  
Jakub Zdroik ◽  
...  

Acoustic seafloor measurements with multibeam echosounders (MBESs) are currently often used for submarine habitat mapping, but the MBESs are usually not acoustically calibrated for backscattering strength (BBS) and cannot be used to infer absolute seafloor angular dependence. We present a study outlining the calibration and showing absolute backscattering strength values measured at a frequency of 150 kHz at around 10–20 m water depth. After recording bathymetry, the co-registered backscattering strength was corrected for true incidence and footprint reverberation area on a rough and tilted seafloor. Finally, absolute backscattering strength angular response curves (ARCs) for several seafloor types were constructed after applying sonar backscattering strength calibration and specific water column absorption for 150 kHz correction. Thus, we inferred specific 150 kHz angular backscattering responses that can discriminate among very fine sand, sandy gravel, and gravelly sand, as well as between bare boulders and boulders partially overgrown by red algae, which was validated by video ground-truthing. In addition, we provide backscatter mosaics using our algorithm (BBS-Coder) to correct the angle varying gain (AVG). The results of the work are compared and discussed with the published results of BBS measurements in the 100–400 kHz frequency range. The presented results are valuable in extending the very sparse angular response curves gathered so far and could contribute to a better understanding of the dependence of backscattering on the type of bottom habitat and improve their acoustic classification.


2021 ◽  
Vol 16 (11) ◽  
pp. P11021
Author(s):  
S.W. Yang ◽  
M.J. Han ◽  
S.K. Park

Abstract Brachytherapy is a cancer treatment that involves intensively irradiating a tumor by placing a sealed radioactive isotope inside the body. Determining the position of the source through accurate quality assurance (QA) is important, because brachytherapy uses radioactive isotope sources with high dose rates. However, in clinical practice, the source position is determined with the naked eye through the use of a ruler, autoradiograph, video monitor, etc., which yields inaccurate results. Therefore, in this study, a lead (II) iodide (PbI2) based polycrystalline digital dosimeter that can measure the relative dose was developed for the QA of the brachytherapy device, and its applicability was evaluated in terms of reproducibility, linearity, percentage interval distance (PID), and angular dependence. Reproducibility evaluation yielded a relative standard deviation value of 1.41%, which satisfied the evaluation criterion of 1.5%. The linearity evaluation yielded an R2 value of 0.9993, which satisfied the evaluation criterion of 0.9990. The PID evaluation revealed that, as the distance from the source increased, the signal decreased according to the inverse-square law. When the PbI2-based digital dosimeter was rotated up to 45°, a difference of up to 13.20% in the angular dependence was observed. Thus, the dosimeter fabricated in this experiment met all the criteria of the aforementioned evaluations. Therefore, it is considered to be highly applicable as a dosimeter for the QA of brachytherapy devices.


Sign in / Sign up

Export Citation Format

Share Document