Current understanding of the origin of equiaxed grains in pure metals during ultrasonic solidification and a comparison of grain formation processes with low frequency vibration, pulsed magnetic and electric-current pulse techniques

2021 ◽  
Vol 65 ◽  
pp. 38-53 ◽  
Author(s):  
Nagasivamuni Balasubramani ◽  
Gui Wang ◽  
David H. StJohn ◽  
Matthew S. Dargusch
Metals ◽  
2019 ◽  
Vol 9 (5) ◽  
pp. 571 ◽  
Author(s):  
Ning Li ◽  
Limin Zhang ◽  
Rong Zhang ◽  
Pengfei Yin ◽  
Hui Xing ◽  
...  

Experiments on transient directional solidification were carried out to study the columnar to equiaxed transition (CET) in Al-7Si alloy without and with an alternating electric current pulse (AECP). Without AECP, the macrostructure consists of typical columnar and equiaxed zones, separated by a near horizontal plane. As the AECP is applied during solidification, an additional fine equiaxed zone (FEZ) occurs in the as-cast macrostructure. From measured temperature profiles, cooling rate and temperature gradient are determined. It is found that CET occurs for a critical value of the cooling rate, which is observed to be about 0.14 K·s−1 in the present investigation. Furthermore, the macrostructural observation with mold for embedding the mesh plate demonstrates that the major factor responsible for the formation of fine equiaxed grains is the detachment of crystal nuclei from the upper contact surface and the lateral wall. The detachment is in turn ascribed to electric current-associated free energy change (ΔGe)-induced the driving force F.


2015 ◽  
Vol 31 (13) ◽  
pp. 1555-1559 ◽  
Author(s):  
W. B. Dai ◽  
J. K. Yu ◽  
C. M. Du ◽  
L. Zhang ◽  
X. L. Wang

2009 ◽  
Vol 83-86 ◽  
pp. 1251-1253 ◽  
Author(s):  
E.G. Grigoryev ◽  
V.N. Bazanov

The purpose of the work was to determine the capabilities of the pulse effect of electric current and pressure to produce welded joints of various component parts of different thickness from 18-10 stainless steel and titanium. Application of electric current pulses on the surfaces of contacting metallic conductors leads to considerable changes in the surface structure. Depending on the initial state of the surfaces and parameters of the pulse effect this can result in melting without formation of joints, formation of a strong welded joint with characteristics no worse than those of welded metals, and in destruction of the contact zone. A combination of a short electric pulse with simultaneous application of mechanical pressure in the weld zone causes high-speed deformation of the contact zone. The process of joint formation itself does not cause any appreciable diffusion during welding. The greatest energy emission and the maximal heating occur on the contacting surfaces being welded with the passage of an electric current pulse through the welding zone. Simultaneously with intensive heating, and due to applied pressure, high-speed deformation of materials takes place and a strong welded joint is formed. Optimal parameters for the welding of titanium and 18-10 stainless steel have been determined on the basis of the tests conducted. Investigations into the welding of titanium and 18-10 stainless steel have shown that application of a short electric current pulse and pressure produces stronger welded joints composed of both similar and different metals of considerably different thickness.


Materials ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 2220 ◽  
Author(s):  
Haiyang Lv ◽  
Rongfeng Zhou ◽  
Lu Li ◽  
Haitao Ni ◽  
Jiang Zhu ◽  
...  

The effect of electric current pulse on the microstructure and corrosion resistance of hypereutectic high chromium cast iron was explored. The morphology of carbides in solidification microstructure was observed by an optical microscope and a scanning electron microscope and the composition was determined by an electron probe micro-analyzer. The microhardness of primary carbides and corrosion resistance of samples were also compared. Under the active of electric current pulse, the microstructure of hypereutectic high chromium cast iron was homogenized and its performance improved accordingly. On treatment by electric current, the morphology of primary carbides changed from thick long rods to hexagonal blocks or granular structures. The interlayer spacing of eutectic carbide decreased from ~26.3 μm to ~17.8 μm. Size statistics showed that the average diameter of primary carbide decreased from ~220 μm to ~60 μm. As a result, microhardness increased from 1412 HV to 1511 HV. No obvious microcrack propagation was found at the microindentation sites. The average length of microcracks decreased from ~20.7 μm to ~5.7 μm. Furthermore, corrosion resistance was remarkably enhanced. The average corrosion rate decreased from 2.65 mg/cm2·h to 1.74 mg/cm2·h after pulse current treatment.


2019 ◽  
Vol 26 (1) ◽  
pp. 34-40
Author(s):  
Teng MA ◽  
Guihong GENG ◽  
Xiaosi SUN ◽  
Xi HAO ◽  
Weixin HAO

The effect of high-density electric current pulse (ECP) on the solidification of Cu-37.4 wt.%Pb monotectic alloy melt was investigated. The microstructure formation mechanisms of ECP were clarified according to liquid metal cluster theory. The results demonstrated that with ECP treatment, the microstructure of Cu-Pb monotectic alloy became finer, the distribution of Pb phase in the matrix was more even and the solute trapping was significantly apparent. Based on the metal liquid cluster theory under ECP, the solid solubility increase result might be due to the salvation clusters increase under the action of pulse current, leading to the binding force increase among solute atoms and solvent atoms. Simultaneously, the aforementioned results were verified through the Differential Scanning Calorimetry (DSC) curve analysis. The results of hardness test, anti-friction test and wear- resistance test show that the ECP can enhance the hardness, improve the properties of anti-friction and wear-resistance of the alloy.


Author(s):  
Nafiseh Mohammadtabar ◽  
Mohammad Bakhshi-jooybari ◽  
Hamid Gorji ◽  
Roohollah Jamaati ◽  
Jerzy A. Szpunar

Abstract The present work focused on the effect of the electric current pulse type on the springback, microstructure, texture, and mechanical properties during the V-bending process of AA2024 aluminum alloy. In order to investigate this effect, three different forming conditions including conventional V-bending and electrically assisted V-bending with square and sinusoidal pulses were considered. The results indicated that the amount of springback significantly decreased from 45.5° (for the sample formed via conventional V-bending) to 24° by applying the sinusoidal pulse. Microstructural observations revealed lower stored energy in the samples formed by electric current pulses which resulted in larger grain size compared to the samples formed without electric pulses. In addition, the result showed that the intensity of the (111)||BLD (bend line direction) fiber texture reduced after applying electric current pulses whereas it was very strong in the sample formed without electric pulses. It was suggested that the electric current pulses led to change the slip plane of the dislocations from {111} to {110} through cross slip. The applying electric current pulses decrease the ultimate tensile strength (UTS) from 471.1 MPa (for the conventional tensile test) to 448.0 and 426.7 MPa for the square and sinusoidal pulses, respectively. On the other hand, the electric pulses improved the formability of the AA2024 alloy owing to the activation of more slip systems, inhibition of dislocation pinning, the promotion of dislocation movement, and the acceleration of restoration mechanisms.


2017 ◽  
Vol 33 (12) ◽  
pp. 1417-1420 ◽  
Author(s):  
D. B. Jia ◽  
W. B. Dai ◽  
G. P. Tang ◽  
C. Z. Xu ◽  
X. Z. Tian ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document