A review on thermal comfort, indoor air quality and energy consumption in temples

2020 ◽  
pp. 102013
Author(s):  
Ahmet Yüksel ◽  
Müslüm Arıcı ◽  
Michal Krajčík ◽  
Mihriban Civan ◽  
Hasan Karabay
Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4436
Author(s):  
María Jesús Romero-Lara ◽  
Francisco Comino ◽  
Manuel Ruiz de Adana

Efficient air-cooling systems for hot climatic conditions, such as Southern Europe, are required in the context of nearly Zero Energy Buildings, nZEB. Innovative air-cooling systems such as regenerative indirect evaporative coolers, RIEC and desiccant regenerative indirect evaporative coolers, DRIEC, can be considered an interesting alternative to direct expansion air-cooling systems, DX. The main aim of the present work was to evaluate the seasonal performance of three air-cooling systems in terms of air quality, thermal comfort and energy consumption in a standard classroom. Several annual energy simulations were carried out to evaluate these indexes for four different climate zones in the Mediterranean area. The simulations were carried out with empirically validated models. The results showed that DRIEC and DX improved by 29.8% and 14.6% over RIEC regarding thermal comfort, for the warmest climatic conditions, Lampedusa and Seville. However, DX showed an energy consumption three and four times higher than DRIEC for these climatic conditions, respectively. RIEC provided the highest percentage of hours with favorable indoor air quality for all climate zones, between 46.3% and 67.5%. Therefore, the air-cooling systems DRIEC and RIEC have a significant potential to reduce energy consumption, achieving the user’s thermal comfort and improving indoor air quality.


Buildings ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 591
Author(s):  
Lin-Rui Jia ◽  
Jie Han ◽  
Xi Chen ◽  
Qing-Yun Li ◽  
Chi-Chung Lee ◽  
...  

Thermal comfort and indoor air quality (IAQ) of educational buildings can affect students’ academic performance and well-being and are closely related to ventilation energy consumption. Demands of the indoor environmental quality within the classroom generally vary with the education levels and result in ventilation energy consumption accounting for a considerable proportion of the total energy use in bulk educational buildings. Its huge energy-saving potential is attracting worldwide attention from scholars and governments. Therefore, appropriate operation strategies of ventilation systems should be adopted to effectively reduce energy consumption without sacrificing thermal comfort and IAQ. However, the absence of relevant standards and guidelines for designing a quality classroom environment considering the special features of educational buildings remains an important research question. This study conducts a comprehensive review to determine research gaps and identify future directions for the interaction between thermal comfort, IAQ and ventilation energy consumption for educational buildings. The review results show that: (1) The thermal comfort prediction model should consider the influences of genders, ages and socioeconomic backgrounds; (2) The mixed-mode ventilation coupling the natural and mechanical approaches is preferred given its advantage of lower energy consumption and improved thermal comfort, but its control strategies need further exploration; (3) Optimizing passive design parameters of buildings (e.g., window to wall ratios, window orientations and sun shading installations) can significantly reduce the ventilation demands while maintaining indoor thermal comfort; (4) More studies are required for investigating thermal comfort in educational buildings during the heating period; and (5) IAQ of university buildings clearly requires further studies, especially on bacterial and fungal aerosol pollutants, for a more comprehensive assessment of the built environment.


2016 ◽  
Vol 138 (5) ◽  
Author(s):  
Pradip Aryal ◽  
Thananchai Leephakpreeda

This research is to assess effects of a partition on thermal comfort, indoor air quality (IAQ), energy consumption, and perception in an air-conditioned space via computational fluid dynamics (CFD) analysis. The variables of indoor air are numerically determined before/after installation/removal of a partition. Accordingly, predicted mean vote (PMV) of thermal comfort, carbon dioxide concentration, rate of energy consumption in making up air, and an overall perception index are proposed to quantify effects in a partitioned space. For a case study, a partition is used to tightly separate a study area from a rest area in a library during peak time. The CFD analysis is performed so that the mean differences between the measured and simulated variables at 14 locations are less than 5%. After partitioning in the CFD analysis, it is found that the average PMV value decreases to −1.4 in the rest area, and it remains at −0.7 in the study area where occupants perceive a slightly cool sensation. In the study area, the carbon dioxide concentration increases to 450–500 ppm, while the rate of energy consumption increases by 8.3%. From the overall perception index of 0.9, the occupants feel spacious in the partitioned areas. Therefore, installing the partition is encouraged with the recommendation that cooling supply can be reduced for energy savings. It is apparent that the proposed methodology yields quantitative indicators for decision making of installation/removal of partitions. The interior investigation of partitions in buildings can be performed before making real physical changes.


Author(s):  
M. F. Mohamed ◽  
M. Behnia ◽  
S. King ◽  
D. Prasad

Cross ventilation is a more effective ventilation strategy in comparison to single-sided ventilation. In the NSW Residential Flat Design Code1 (RFDC) the majority of apartments are required to adopt cross ventilation. However, in the case of studio and one-bedroom apartments, it is acknowledged that single-sided ventilation may prevail. Deep plan studio and one-bedroom apartments may achieve lower amenity of summer thermal comfort and indoor air quality where mechanical ventilation is not provided by air conditioning. Since compliance with the code may allow up to 40% of apartments in a development in Sydney to be single sided, it is important to understand the natural ventilation performance of such apartments. The objective of this paper is to investigate the natural ventilation potential in single-sided ventilated apartments to improve indoor air quality and thermal comfort. This investigation includes simulating various facade treatments involving multiple opening and balcony configurations. Balcony configurations are included in this study because, in Sydney, a balcony is a compulsory architectural element in any apartment building. The study uses computational fluid dynamics (CFD) software to simulate and predict the ventilation performance of each apartment configuration. This study suggests that properly configured balconies and openings can significantly improve indoor ventilation performance for enhanced indoor air quality and thermal comfort, by optimizing the available prevailing wind. However, it is important to note that inappropriately designed fac¸ade treatments also could diminish natural ventilation performance.


2016 ◽  
pp. 67-98
Author(s):  
T. Agami Reddy ◽  
Jan F. Kreider ◽  
Peter S. Curtiss ◽  
Ari Rabl

2021 ◽  
Vol 246 ◽  
pp. 03005
Author(s):  
Eusébio Conceição ◽  
João Gomes ◽  
Mª Manuela Lúcio ◽  
Hazim Awbi

In this numerical study the energy production in solar collectors in a University building used to improve the internal thermal conditions is made. Passive and active solutions, using external solar collector and internal thermo-convectors, are used. The numerical simulation, in transient conditions, is done for a winter typical day with clean sky. This numerical study was carried out using a software that simulates the Building Dynamic Response with complex topology in transient conditions. The software evaluates the human thermal comfort and indoor air quality levels that the occupants are subjected, Heated Ventilation and Air Conditioned energy consumption, indoor thermal variables and other parameters. The university building has 107 compartments and is located in a Mediterranean-type environment. External solar water collectors, placed above the building’s roof, and internal thermo-convectors of water/air type, using mixing ventilation, are used as passive and active strategies, respectively. The thermal comfort level, using the Predicted Mean Vote index, and the indoor air quality, using the carbon dioxide concentration, are evaluated. The results show that in winter conditions the solar collectors improve the thermal comfort conditions of the occupants. The indoor air quality, in all ventilated spaces, is also guaranteed.


Sign in / Sign up

Export Citation Format

Share Document