A novel full-field experimental method to measure the local compressibility of gas diffusion media

2010 ◽  
Vol 195 (10) ◽  
pp. 3215-3223 ◽  
Author(s):  
Yeh-Hung Lai ◽  
Yongqiang Li ◽  
Jeffrey A. Rock
Author(s):  
N. Akhtar ◽  
P. J. A. M. Kerkhof

The role of gas diffusion media with differently structured properties have been examined with emphasis on the liquid water saturation within the cathode of a proton exchange membrane fuel cell (PEMFC). The cathode electrode consists of a gas diffusion layer (GDL), a micro-porous layer and a catalyst layer (CL). The liquid water saturation profiles have been calculated for varying structural and physical properties, i.e., porosity, permeability, thickness and contact angle for each of these layers. It has been observed that each layer has its own role in determining the liquid water saturation within the CL. Among all the layers, the GDL is the most influential layer that governs the transport phenomena within the PEMFC cathode. Besides, the thickness of the CL also affects the liquid water saturation and it should be carefully controlled.


Author(s):  
Derek W. Fultz ◽  
Po-Ya Abel Chuang

Two fuel cell architectures, differing only by the surfaces onto which the electrodes were applied, have been analyzed to determine the root causes of dissimilarities in performance. The basic proton exchange membrane fuel cell (PEMFC) is comprised of the proton transporting membrane, platinum-containing anode and cathode electrodes, porous carbon fiber gas diffusion media (GDM), and flow fields which deliver the reactant hydrogen and air flows. As no optimal cell design currently exists, there is a degree of latitude regarding component assembly and structure. Catalyst coated diffusion media (CCDM) refers to a cell architecture option where the electrode layers are coated on the GDM layers and then hot-pressed to the membrane. Catalyst coated membrane (CCM) refers to an architecture where the electrodes are transferred directly onto the membrane. A cell with CCDM architecture has tightly bonded interfaces throughout the assembly which can result in lower thermal and electrical contact resistances. Considering the fuel cell as a 1-D thermal system, the through-plane thermal resistance was observed to decrease by 5–10% when comparing CCDM to CCM architectures. This suggests the thermal contact resistance at the electrode interfaces was significantly reduced in the hot-press process. In addition, the electrical contact resistances between the electrode and GDM were observed to be significantly reduced with a CCDM architecture. This study shows that these effects, which have a potential to increase performance, can be attributed to the hot-press lamination process and use of CCDM architecture.


2002 ◽  
Vol 2002-31 (1) ◽  
pp. 198-211
Author(s):  
Uwe Beuscher

Author(s):  
Jeffrey T. Gostick ◽  
Marios A. Ioannidis ◽  
Michael W. Fowler ◽  
Mark D. Pritzker

2014 ◽  
Vol 64 (3) ◽  
pp. 487-499 ◽  
Author(s):  
P. Mangal ◽  
M. Dumontier ◽  
N. Carrigy ◽  
M. Secanell

Author(s):  
Joshua Preston ◽  
Richard Fu ◽  
Xiaoyu Zhang ◽  
Ugur Pasaogullari

An investigation of the liquid water saturation across the cross-section of an operating polymer electrolyte fuel cell is performed to analyze the saturation discontinuity predicted by numerical models. Numerical models have predicted a discontinuity in the liquid water saturation at the interface of the micro-porous layer and the coarser macroporous region of the gas diffusion layer. High-resolution through plane neutron radiography is used to acquire the water content distribution across the thickness of the gas-diffusion layer and study the effects of the interface. The measured liquid water profiles indicate no obvious discontinuity in the liquid water saturation across the cross-section of the bi-layer gas diffusion layer when large areas are averaged spatially. Evidence of the discontinuity is found when small spatial averaging is used in certain locations. Other locations show no evidence of the discontinuity. Scanning electron microscopy is used to examine the microstructure of two types of the bi-layer diffusion media. The images show that the approximation of the interface as a sudden, distinct feature may not be appropriate. The results suggest that a model that considers the existence of an interfacial region in the diffusion media may be appropriate, in which the properties vary continuously.


Energies ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1831 ◽  
Author(s):  
Riccardo Balzarotti ◽  
Saverio Latorrata ◽  
Marco Mariani ◽  
Paola Gallo Stampino ◽  
Giovanni Dotelli

A hydrophobic perfluoropolyether (PFPE)-based polymer, namely Fluorolink® P56, was studied instead of the commonly used polytetrafluoroethylene (PTFE), in order to enhance gas diffusion media (GDM) water management behavior, on the basis of a previous work in which such polymers had already proved to be superior. In particular, an attempt to optimize the GDM production procedure and to improve the microporous layer (MPL) adhesion to the substrate was carried out. Materials properties have been correlated with production routes by means of both physical characterization and electrochemical tests. The latter were performed in a single PEM fuel cell, at different relative humidity (namely 80% on anode side and 60%/100% on cathode side) and temperature (60 °C and 80 °C) conditions. Additionally, electrochemical impedance spectroscopy measurements were performed in order to assess MPLs properties and to determine the influence of production procedure on cell electrochemical parameters. The durability of the best performing sample was also evaluated and compared to a previously developed benchmark. It was found that a final dipping step into PFPE-based dispersion, following MPL deposition, seems to improve the adhesion of the MPL to the macro-porous substrate and to reduce diffusive limitations during fuel cell operation.


Sign in / Sign up

Export Citation Format

Share Document