scholarly journals Prime oxygen concentration has no effect on placental vascular resistance for fetal cardiac bypass

2014 ◽  
Vol 147 (3) ◽  
pp. 1107-1108
Author(s):  
Charles R. Cole ◽  
R. Scott Baker ◽  
Danielle Herbert ◽  
Pirooz Eghtesady
Author(s):  
H. Takaoka ◽  
M. Tomita ◽  
T. Hayashi

High resolution transmission electron microscopy (HRTEM) is the effective technique for characterization of detailed structure of semiconductor materials. Oxygen is one of the important impurities in semiconductors. Detailed structure of highly oxygen doped silicon has not clearly investigated yet. This report describes detailed structure of highly oxygen doped silicon observed by HRTEM. Both samples prepared by Molecular beam epitaxy (MBE) and ion implantation were observed to investigate effects of oxygen concentration and doping methods to the crystal structure.The observed oxygen doped samples were prepared by MBE method in oxygen environment on (111) substrates. Oxygen concentration was about 1021 atoms/cm3. Another sample was silicon of (100) orientation implanted with oxygen ions at an energy of 180 keV. Oxygen concentration of this sample was about 1020 atoms/cm3 Cross-sectional specimens of (011) orientation were prepared by argon ion thinning and were observed by TEM at an accelerating voltage of 400 kV.


1992 ◽  
Vol 05 (03) ◽  
pp. 128-130
Author(s):  
Dana Allen ◽  
Doris Dyson

Xylazine/ketamine was shown to be the most cardio-depressive anaesthetic. The fall in cardiac output, in spite of increased vascular resistance, could not maintain BP within an acceptable range. Acepromazine/ketamine and premix/thiopental are comparable and less depressive than xylazine/ketamine.


2012 ◽  
Vol 8 (3) ◽  
pp. 209
Author(s):  
Wouter Jacobs ◽  
Anton Vonk-Noordegraaf ◽  
◽  

Pulmonary arterial hypertension is a progressive disease of the pulmonary vasculature, ultimately leading to right heart failure and death. Current treatment is aimed at targeting three different pathways: the prostacyclin, endothelin and nitric oxide pathways. These therapies improve functional class, increase exercise capacity and improve haemodynamics. In addition, data from a meta-analysis provide compelling evidence of improved survival. Despite these treatments, the outcome is still grim and the cause of death is inevitable – right ventricular failure. One explanation for this paradox of haemodynamic benefit and still worse outcome is that the right ventricle does not benefit from a modest reduction in pulmonary vascular resistance. This article describes the physiological concepts that might underlie this paradox. Based on these concepts, we argue that not only a significant reduction in pulmonary vascular resistance, but also a significant reduction in pulmonary artery pressure is required to save the right ventricle. Haemodynamic data from clinical trials hold the promise that these haemodynamic requirements might be met if upfront combination therapy is used.


Sign in / Sign up

Export Citation Format

Share Document