Mechanical behavior of carbon fiber reinforced polymer composite sandwich panels with 2-D lattice truss cores

2014 ◽  
Vol 55 ◽  
pp. 591-596 ◽  
Author(s):  
Bing Wang ◽  
Guoqi Zhang ◽  
Qilin He ◽  
Li Ma ◽  
Linzhi Wu ◽  
...  
2018 ◽  
Vol 284 ◽  
pp. 43-47
Author(s):  
M.S. Nikhamkin ◽  
N.A. Sazhenkov ◽  
D. Samodurov

The carbon fiber reinforced polymer composite are widely used in industry as major structural materials. They represent the greatest interest for the production of gas turbine engines parts because of their high specific strength. But before adaptation these materials into the structure, it is necessary to conduct a number of tests, both on test coupon and on structurally equivalent samples for determining physical, in particular, fatigue properties of these materials. However, the high cost of manufacturing coupons for such tests has a negative impact on the adaptation of carbon fiber reinforced polymer composite into the composition of final products. In this paper it is presented a method for fatigue tests of test coupon and structurally equivalent samples of carbon fiber reinforced polymer, aimed at reducing the consumption of coupons which are necessary for obtaining fatigue properties. Based on the developed method, a series of carbon fiber coupons was tested and the fatigue limit was obtained. At the same time, the use of coupons was minimized.


Materials ◽  
2020 ◽  
Vol 13 (1) ◽  
pp. 222
Author(s):  
Liangliang Wei ◽  
Ji-Hua Zhu ◽  
Zhijun Dong ◽  
Jun Liu ◽  
Wei Liu ◽  
...  

Carbon fiber reinforced polymer (CFRP) has been used as a dual-functional material in a hybrid intervention system (ICCP-SS) which integrates the impressed current cathodic protection (ICCP) and structural strengthening (SS). The mechanical behavior of CFRP as an anode has been investigated in some solution environments. However, the anodic and mechanical behavior of CFRP bonded to concrete is unclear. This paper focuses on the anodic and mechanical performance of CFRP bonded to the chloride-contaminated concrete by conducting an electrochemical (EC) test. The method of bonding the CFRP to the concrete and the shape of the steel embedded in the concrete were considered. The current densities of 20 mA/m2 and 100 mA/m2 were applied during 120-day and 310-day EC tests. The electrode potentials and driving voltages were recorded, and the bond interfaces of the CFRP were inspected after EC test. The residual tensile strength and failure modes of the CFRP were analyzed after tensile tests. Finally, the long-term performance of CFRP as a dual-functional material in ICCP-SS system was discussed. Results show that the externally bonding CFRP in ICCP-SS system can not only protect the steel in chloride-contaminated concrete effectively but also maintain 70% of the original tensile strength of CFRP at a charge density of 744 A·h/m2. The expected service period of CFRP as a dual-functional material bonded to the chloride-contaminated concrete was determined to be more than 42.5 years.


Sign in / Sign up

Export Citation Format

Share Document