Heat transfer and flow characteristics around a finned-tube bank heat exchanger in fluidized bed

Author(s):  
Ryosuke Honda ◽  
Hisashi Umekawa ◽  
Mamoru Ozawa
2007 ◽  
Vol 2007.82 (0) ◽  
pp. _11-8_
Author(s):  
Yohei TSUJI ◽  
Ryosuke HONDA ◽  
Hisashi UMEKAWA ◽  
Mamoru OZAWA

2018 ◽  
Vol 6 (3) ◽  
pp. 1-12
Author(s):  
Kamil Abdul Hussien

Abstract-The present work investigates the enhancement of heat transfer by using different number of circular fins (8, 10, 12, 16, and 20) in double tube counter flow heat exchanger experimentally. The fins are made of copper with dimensions 66 mm OD, 22 mm ID and 1 mm thickness. Each fin has three of 14 mm diameter perforations located at 120o from each to another. The fins are fixed on a straight smooth copper tube of 1 m length, 19.9 mm ID and 22.2 mm OD. The tube is inserted inside the insulated PVC tube of 100 mm ID. The cold water is pumped around the finned copper tube, inside the PVC, at mass flow rates range (0.01019 - 0.0219) kg/s. The Reynold's number of hot water ranges (640 - 1921). The experiment results are obtained using six double tube heat exchanger (1 smooth tube and the other 5 are finned one). The results, illustrated that the heat transfer coefficient proportionally with the number of fin. The results also showed that the enhancement ratio of heat transfer for finned tube is higher than for smooth tube with (9.2, 10.2, 11.1, 12.1 13.1) times for number of fins (8, 10, 12, 16 and 20) respectively.


2021 ◽  
Vol 3 (4) ◽  
Author(s):  
Sirine Chtourou ◽  
Hassene Djemel ◽  
Mohamed Kaffel ◽  
Mounir Baccar

AbstractThis study presents a numerical analysis of a laminar counter flow inside small channels plate heat exchanger fitted with Y and C shape obstacles. Using the Computational Fluid Dynamics CFD, an advanced and modern simulation technique, the influence of the geometrical parameters (such as geometry, rib pitch) on the flow characteristics, the thermal and the hydrodynamics performance of the PHE (plate heat exchanger) is investigated numerically. The main goal of this work is to increase the flow turbulence, enhance the heat transfer and the thermal efficiency by inserting new obstacles forms. The computational domain is a conjugate model which is developed by the Computer Aided Design CAD software Solidworks. The results, obtained with Ansys Fluent, show that the presence of the shaped ribs provides enhancement in heat transfer and fluid turbulence. The CFD analysis is validated with the previous study. The non-dimensional factors such as the Nusselt number Nu, the skin friction factor Cf and the thermo-hydraulic performance parameter THPP are predicted with a Reynolds number Re range of 200–800. The temperature and the velocity distribution are presented and analyzed. The Y ribs and the C ribs offer as maximum THPP values respectively about 1.44 and 2.6 times of a smooth duct.


Author(s):  
Ignacio Carvajal-Mariscal ◽  
Florencio Sanchez-Silva ◽  
Georgiy Polupan

In this work the heat transfer and pressure drop experimental results obtained in a two step finned tube bank with conical fins are presented. The tube bank had an equilateral triangle array composed of nine finned tubes with conical fins inclined 45 degrees in respect with the tube axis. The heat exchange external area of a single tube is approximately 0.07 m2. All necessary thermal parameters, inlet/outlet temperatures, mass flows, for the heat balance in the tube bank were determined for different air velocities, Re = 3400–18400, and one constant thermal charge provided by a hot water flow with a temperature of 80 °C. As a result, the correlations for the heat transfer and pressure drop calculation were obtained. The experimental results were compared against the analytical results for a tube bank with annular fins with the same heat exchange area. It was found that the proposed tube bank using finned tubes with conical fins shows an increment of heat transfer up to 58%.


Sign in / Sign up

Export Citation Format

Share Document