scholarly journals Development of a label-free-SERS gold nanoaptasensor for the accessible determination of ochratoxin A

2020 ◽  
Vol 28 ◽  
pp. 100331 ◽  
Author(s):  
Yulán Hernández ◽  
Lesly K. Lagos ◽  
Betty C. Galarreta
Keyword(s):  
Toxins ◽  
2019 ◽  
Vol 11 (2) ◽  
pp. 71 ◽  
Author(s):  
Mina Nan ◽  
Yang Bi ◽  
Huali Xue ◽  
Sulin Xue ◽  
Haitao Long ◽  
...  

A simple and sensitive label-free impedimetric aptasensor for rapid determination of ochratoxin A (OTA) has been developed, which was based on the combination between thiolated aptamer and gold nanoparticles by layer-by-layer self-assembly. Because of the interaction between aptamer and OTA, the relative normalized electron-transfer resistance (ΔRct) values obtained by electrochemical impedance spectroscopy (EIS) was proportional to the concentration of OTA and showed a good linear relationship from 0.1 to 10.0 ng/mL, with a lower detection limit (0.030 ng/mL) than one-step thiolated DNA aptasensor. The established method was successfully applied to detect and analyze OTA in table wine and grape juice, and the recovery was 90.56%–104.21% when PVP effective removed of phenolic substances. The label-free impedimetric aptasensor was used for rapid detection and quantitation of OTA in the inoculated grapes with the Aspergillus Nigri (H1), and the production of OTA (62.4 μg/kg, 20 μg/kg) far exceeded the maximum levels of 2 μg/kg after inoculation for three days. The developed method exhibited a good specificity, high sensitivity, time-efficient, and it could be applied to detect the OTA concentration in grape and its commodities.


2017 ◽  
Vol 35 (2) ◽  
pp. 185 ◽  
Author(s):  
Xiaoming GONG ◽  
Ronghui MA ◽  
Hongtao WANG ◽  
Liqiang GUO ◽  
Kai LI ◽  
...  

2021 ◽  
Vol 379 ◽  
pp. 138172
Author(s):  
Maham Liaqat ◽  
Sara Riaz ◽  
Mian Hasnain Nawaz ◽  
Mihaela Badea ◽  
Akhtar Hayat ◽  
...  

Heliyon ◽  
2021 ◽  
Vol 7 (4) ◽  
pp. e06663
Author(s):  
Mariel Cina ◽  
María del Valle Ponce ◽  
Luis Dante Martinez ◽  
Soledad Cerutti
Keyword(s):  

2021 ◽  
Vol 334 ◽  
pp. 129682
Author(s):  
Xiujuan Qiao ◽  
Xin Ma ◽  
Xiaoyu Ma ◽  
Tianli Yue ◽  
Qinglin Sheng

Toxins ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 547
Author(s):  
Kai Zhang

Two methods for measuring ochratoxin A in corn, oat, and grape juice were developed and compared. Flow injection (FI) and on-line liquid chromatography (LC) performances were evaluated separately, with both methods using a triple quadrupole tandem mass spectrometer (MS/MS) for quantitation. Samples were fortified with 13C uniformly labeled ochratoxin A as the internal standard (13C-IS) and prepared by dilution and filtration, followed by FI- and LC-MS/MS analysis. For the LC-MS/MS method, which had a 10 min run time/sample, recoveries of ochratoxin A fortified at 1, 5, 20, and 100 ppb in corn, oat, red grape juice, and white grape juice ranged from 100% to 117% with RSDs < 9%. The analysis time of the FI-MS/MS method was <60 s/sample, however, the method could not detect ochratoxin A at the lowest fortification concentration, 1 ppb, in all tested matrix sources. At 5, 20, and 100 ppb, recoveries by FI-MS/MS ranged from 79 to 117% with RSDs < 15%. The FI-MS/MS method also had ~5× higher solvent and matrix-dependent instrument detection limits (0.12–0.35 ppb) compared to the LC-MS/MS method (0.02–0.06 ppb). In the analysis of incurred corn and oat samples, both methods generated comparable results within ±20% of reference values, however, the FI-MS/MS method failed to determine ochratoxin A in two incurred wheat flour samples due to co-eluted interferences due to the lack of chromatographic separation.


Sign in / Sign up

Export Citation Format

Share Document