Knee joint kinematics during the sidestep maneuver in professional futsal athletes: Effect of sport-specific sidestep cutting

Author(s):  
B.L.S. Bedo ◽  
G.M. Cesar ◽  
A.M. Vieira ◽  
L.H.P. Vieira ◽  
D.S. Catelli ◽  
...  
The Knee ◽  
2021 ◽  
Vol 29 ◽  
pp. 201-207
Author(s):  
Erik T. Hummer ◽  
Eryn N. Murphy ◽  
David N. Suprak ◽  
Lorrie R. Brilla ◽  
Jun G. San Juan

1977 ◽  
Vol 10 (10) ◽  
pp. 659-673 ◽  
Author(s):  
Richard P. Duke ◽  
James H. Somerset ◽  
Paul Blacharski ◽  
David G. Murray

Author(s):  
Susan M. Moore ◽  
Mary T. Gabriel ◽  
Maribeth Thomas ◽  
Jennifer Zeminski ◽  
Savio L.-Y. Woo ◽  
...  

Knowledge of joint kinematics contributes to the understanding of the function of soft tissue restraints, injury mechanisms, and can be used to evaluate surgical repair techniques. (Tibone, McMahon et al. 1998; Karduna, McClure et al. 2001; Abramowitch, Papageorgiou et al. 2003) Previous studies have measured joint kinematics using a variety of non-invasive methods that include: optical tracking, magnetic tracking, and mechanical linkage systems. (Rudins, Laskowski et al. 1997; Apreleva, Hasselman et al. 1998; Gabriel, Wong et al. 2004) These measurement devices report kinematics of rigid bodies with respect their own global coordinate system. However, it is often useful to understand these kinematics in terms of a coordinate system whose axes coincide with the degrees of freedom of each specific joint (anatomical coordinate systems). Once the kinematics are obtained with respect to the global coordinate system of the measurement device, the joint kinematics can be calculated with respect to anatomical coordinate systems if the relationship between the measurement device and the anatomical coordinate systems are known. Although the accuracy of these kinematic measurement devices is provided by the manufacturer, the effect of their accuracy on joint kinematics reported with respect to anatomical coordinate systems must be determined. (Panjabi, Goel et al. 1982; Crisco, Chen et al. 1994) For example, small errors in orientation of the measurement system could lead to large errors in position for an anatomical coordinate system located at some distance away. As researchers report joint kinematics with respect to the anatomical coordinate systems, understanding the errors produced by one’s measurement device with respect to the anatomical coordinate systems is necessary. Further, a great deal of interest exists for studying knee joint kinematics. (Sakane, Livesay et al. 1999; Lephart, Ferris et al. 2002; Ford, Myer et al. 2003) Within our research center our goal is to collect knee joint kinematics of a cadaver and reproduce them with respect to the anatomical coordinate systems using robotic technology. Therefore, the objective of this study was to determine the effect of the accuracy of three measurement devices (optical tracking device-OptoTrak® 3020, magnetic tracking device-Flock of Birds®, instrumented spatial linkage-EnduraTec Corp.) on knee joint kinematics reported with respect to an anatomical coordinate system.


Author(s):  
Massoud Akbarshahi ◽  
Justin W. Fernandez ◽  
Anthony Schache ◽  
Richard Baker ◽  
Marcus G. Pandy

The ability to accurately measure joint kinematics in vivo is of critical importance to researchers in the field of biomechanics [1]. Applications range from the quantitative evaluation of different surgical techniques, treatment methods and/or implant designs, to the development of computer-based models capable of simulating normal and pathological musculoskeletal conditions [1,2]. Currently, non-invasive marker-based three dimensional (3D) motion analysis is the most commonly used method for quantitative assessment of normal and pathological locomotion. The accuracy of this technique is influenced by movement of the soft tissues relative to the underlying bones, which causes inaccuracies in the determination of segmental anatomical coordinate systems and tracking of segmental motion. The purpose of this study was to quantify the errors in the measurement of knee-joint kinematics due solely to soft-tissue artifact (STA) in healthy subjects. To facilitate valid inter-subject comparisons of the kinematic data, relevant anatomical coordinate systems were defined using 3D bone models generated from magnetic resonance imaging (MRI).


PLoS ONE ◽  
2019 ◽  
Vol 14 (2) ◽  
pp. e0213084 ◽  
Author(s):  
Jing-Sheng Li ◽  
Tsung-Yuan Tsai ◽  
David T. Felson ◽  
Guoan Li ◽  
Cara L. Lewis

2017 ◽  
Vol 39 (01) ◽  
pp. 50-57 ◽  
Author(s):  
Melanie Lesinski ◽  
Olaf Prieske ◽  
Rainer Beurskens ◽  
David Behm ◽  
Urs Granacher

AbstractThe purpose of this study was to examine the combined effects of drop-height and surface condition on drop jump (DJ) performance and knee joint kinematics. DJ performance, sagittal and frontal plane knee joint kinematics were measured in jump experienced young male and female adults during DJs on stable, unstable and highly unstable surfaces using different drop-heights (20, 40, 60 cm). Findings revealed impaired DJ performance (Δ5–16%; p<0.05; 1.43≤d≤2.82), reduced knee valgus motion (Δ33–52%; p<0.001; 2.70≤d≤3.59), and larger maximum knee flexion angles (Δ13–19%; p<0.01; 1.74≤d≤1.75) when using higher (60 cm) compared to lower drop-heights (≤40 cm). Further, lower knee flexion angles and velocity were found (Δ8-16%; p<0.01; 1.49≤d≤2.38) with increasing surface instability. When performing DJs from high (60 cm) compared to moderate drop-heights (40 cm) on highly unstable surfaces, higher knee flexion velocity and maximum knee valgus angles were found (Δ15–19%; p<0.01; 1.50≤d≤1.53). No significant main and/or interaction effects were observed for the factor sex. In conclusion, knee motion strategies were modified by the factors ‘drop-height’ and/or ‘surface instability’. The combination of high drop-heights (>40 cm) together with highly unstable surfaces should be used cautiously during plyometrics because this may increase the risk of injury due to higher knee valgus stress.


Sign in / Sign up

Export Citation Format

Share Document