Seismic performance of a Low-Cost base isolation system for unreinforced brick Masonry buildings in developing countries

2021 ◽  
Vol 141 ◽  
pp. 106501
Author(s):  
Daniele Losanno ◽  
Nagavinothini Ravichandran ◽  
Fulvio Parisi ◽  
Andrea Calabrese ◽  
Giorgio Serino
2012 ◽  
Vol 19 (6) ◽  
pp. 1327-1339 ◽  
Author(s):  
Radhikesh P. Nanda ◽  
Pankaj Agarwal ◽  
Manish Shrikhande

A feasibility study of friction base isolation system for seismic protection has been performed. Four different sliding interfaces, namely, green marble/High Density Poly Ethylene (HDPE), green marble/green marble, green marble/geosynthetic, and green marble/ rubber layers have been studied through experimental and analytical investigations. The experimental investigations show that the coefficient of friction values of these interfaces lies in the desirable range for seismic protection, i.e., 0.05 to 0.15. The analytical investigation reveals that most of these sliding interfaces are effective in reducing spectral accelerations up to 50% and the sliding displacement is restricted within plinth projection of 75 mm (3 in). Green marble and geosynthetic are found to be better alternatives for use in friction isolation system with equal effectiveness of energy dissipation and limiting the earthquake energy transmission to super structure during strong earthquake leading to a low cost, durable solution for earthquake protection of masonry buildings.


2021 ◽  
pp. 875529302098196
Author(s):  
Tansu Gökçe ◽  
Engin Orakdöğen ◽  
Ercan Yüksel

A novel seismic base isolation system has been developed for high-voltage (HV) porcelain post insulators. The seismic isolation device consists of two steel plates, four polyurethane springs, and a steel rod, which are low-cost components compared to the post insulators. Two alternative designs of the device are experimentally and numerically assessed in this article. A simple and robust numerical model consisting of linear line elements and nonlinear springs was generated, and subsequently validated using the experimental results. Incremental dynamic analyses (IDAs) were then performed to obtain fragility curves. Ten historical earthquake profiles, scaled to intensities between 0.1 and 2.0 g, were then applied to the numerical models. The fragility curves, generated according to the latest version of IEEE-693, demonstrate that the seismic isolation devices are highly effective in diminishing the base moment of the porcelain insulator. It should be noted that relatively large displacements at the top of the pole must be accounted for by ensuring adequate slackness in the flexible conductors.


2020 ◽  
Vol 10 (1) ◽  
pp. 45-54
Author(s):  
Soroush Kherad ◽  
Mahmood Hosseini ◽  
Mehrtash Motamedi

AbstractUsing seesaw structural system equipped with energy dissipating devices has been considered as a low-cost and low-tech way for creation of earthquake-resilient buildings. In this paper by considering three groups of multi-story buildings, including conventional buildings, LRB-based isolated buildings and building with seesaw structure, equipped with a newly introduced type of structural fuses, their seismic performances have been compared through nonlinear time history analyses (NLTHA). The employed fuses in seesaw buildings are a specific type of yielding plate dampers, called Multiple Curved Yielding Plate Energy Dissipater (MCYPED), installed at the bottom of the all circumferential columns of the lowest story of the building. To show the efficiency of the proposed seesaw system in comparison with other two mentioned groups, first, by finite element modeling, verified by experimental results, the initial and secondary stiffness values as well as the yielding and ultimate strengths of the MCYPEDs have been obtained to be modeled by multi-linear plastic springs in the seesaw buildings. Then, a series of NLTHA have been performed on the three groups of buildings by using a set of selected earthquakes. The compared responses include roof displacement and acceleration, base shear, inter-story drift and finally plastic hinges (PHs) formed in the building’s structures. Results show that the proposed seesaw building equipped with MCYPEDs not only results in lower seismic demand, similar to base isolation system, but also leads to remarkable energy dissipation capacity in the building structure at base level, so that the building structure remains basically elastic, and does not need any major repair work, even after large earthquakes, contrary to the conventional building which need to be demolished after the earthquake.


Author(s):  
Afroz Qureshi

There has been many researches in order to further improve the Base Isolation system by trying various combinations and alternative materials. In that fiber reinforced isometric isolators are emerged as a viable solution, because for the low cost and effective response to seismic waves as compared to the conventional isolators. Studies further shows that it provides high vertical stiffness and low horizontal stiffness, also having effective damping over the conventional one. Developing countries who doesn’t have proper seismic protection solutions have found this convenient as they are comparatively less in cost and doesn’t require complex installation. Studies also shows Un-bonded FREI has lower horizontal stiffness and considerably lower stress demand on rubber material as compared to the B-FREI and hence significantly higher seismic isolation efficiency.