scholarly journals Contrast Agent-Free Assessment of Blood Flow and Wall Shear Stress in the Rabbit Aorta using Ultrasound Image Velocimetry

Author(s):  
Kai Riemer ◽  
Ethan M. Rowland ◽  
Jacob Broughton-Venner ◽  
Chee Hau Leow ◽  
Mengxing Tang ◽  
...  
2020 ◽  
Vol 48 (6) ◽  
pp. 1728-1739
Author(s):  
K. Riemer ◽  
E. M. Rowland ◽  
C. H. Leow ◽  
M. X. Tang ◽  
P. D. Weinberg

Abstract Abnormal blood flow and wall shear stress (WSS) can cause and be caused by cardiovascular disease. To date, however, no standard method has been established for mapping WSS in vivo. Here we demonstrate wide-field assessment of WSS in the rabbit abdominal aorta using contrast-enhanced ultrasound image velocimetry (UIV). Flow and WSS measurements were made independent of beam angle, curvature or branching. Measurements were validated in an in silico model of the rabbit thoracic aorta with moving walls and pulsatile flow. Mean errors over a cardiac cycle for velocity and WSS were 0.34 and 1.69%, respectively. In vivo time average WSS in a straight segment of the suprarenal aorta correlated highly with simulations (PC = 0.99) with a mean deviation of 0.29 Pa or 5.16%. To assess fundamental plausibility of the measurement, UIV WSS was compared to an analytic approximation derived from the Poiseuille equation; the discrepancy was 17%. Mapping of WSS was also demonstrated in regions of arterial branching. High time average WSS (TAWSSxz = 3.4 Pa) and oscillatory flow (OSIxz = 0.3) were observed near the origin of conduit arteries. In conclusion, we have demonstrated that contrast-enhanced UIV is capable of measuring spatiotemporal variation in flow velocity, arterial wall location and hence WSS in vivo with high accuracy over a large field of view.


2020 ◽  
Vol 59 (SK) ◽  
pp. SKKE16 ◽  
Author(s):  
Ryo Nagaoka ◽  
Kazuma Ishikawa ◽  
Michiya Mozumi ◽  
Magnus Cinthio ◽  
Hideyuki Hasegawa

2021 ◽  
Author(s):  
Chandan Kumawat ◽  
Bhupendra Kumar Sharma ◽  
Khalid Saad Mekheimer

Abstract A two-phase blood flow model is considered to analyze the fluid flow and heat transfer in a curved tube with time-variant stenosis. In both core and plasma regions, the variable viscosity model ( Hematocrit and non linear temperature-dependent, respectively) is considered. A toroidal coordinate system is considered to describe the governing equations. The perturbation technique in terms of perturbation parameter ε is used to obtain the temperature profile of blood flow. In order to find the velocity, wall shear stress and impedance profiles, a second-order finite difference method is employed with the accuracy of 10−6 in the each iteration. Under the conditions of fully-developed flow and mild stenosis, the significance of various physical parameters on the blood velocity, temperature, wall shear stress (WSS) and impedance are investigated with the help of graphs. A validation of our results has been presented and comparison has been made with the previously published work and present study, and it revels the good agreement with published work. The present mathematical study suggested that arterial curvature increase the fear of deposition of plaque (atherosclerosis), while, the use of thermal radiation in heat therapies lowers this risk. The positive add in the value of λ1 causes to increase in plasma viscosity; as a result, blood flow velocity in the stenosed artery decreases due to the assumption of temperature-dependent viscosity of the plasma region. Clinical researchers and biologists can adopt the present mathematical study to lower the risk of lipid deposition, predict cardiovascular disease risk and current state of disease by understanding the symptomatic spectrum, and then diagnose patients based on the risk.


2018 ◽  
Vol 2018 ◽  
pp. 1-16 ◽  
Author(s):  
Mongkol Kaewbumrung ◽  
Somsak Orankitjaroen ◽  
Pichit Boonkrong ◽  
Buraskorn Nuntadilok ◽  
Benchawan Wiwatanapataphee

A mathematical model of dispersed bioparticle-blood flow through the stenosed coronary artery under the pulsatile boundary conditions is proposed. Blood is assumed to be an incompressible non-Newtonian fluid and its flow is considered as turbulence described by the Reynolds-averaged Navier-Stokes equations. Bioparticles are assumed to be spherical shape with the same density as blood, and their translation and rotational motions are governed by Newtonian equations. Impact of particle movement on the blood velocity, the pressure distribution, and the wall shear stress distribution in three different severity degrees of stenosis including 25%, 50%, and 75% are investigated through the numerical simulation using ANSYS 18.2. Increasing degree of stenosis severity results in higher values of the pressure drop and wall shear stresses. The higher level of bioparticle motion directly varies with the pressure drop and wall shear stress. The area of coronary artery with higher density of bioparticles also presents the higher wall shear stress.


Author(s):  
Florian von Knobelsdorff-Brenkenhoff ◽  
Achudhan Karunaharamoorthy ◽  
Ralf Felix Trauzeddel ◽  
Alex J. Barker ◽  
Edyta Blaszczyk ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document