Chlorine disinfection significantly aggravated the biofouling of reverse osmosis membrane used for municipal wastewater reclamation

2019 ◽  
Vol 154 ◽  
pp. 246-257 ◽  
Author(s):  
Yun-Hong Wang ◽  
Yin-Hu Wu ◽  
Xin Tong ◽  
Tong Yu ◽  
Lu Peng ◽  
...  
Desalination ◽  
2014 ◽  
Vol 349 ◽  
pp. 73-79 ◽  
Author(s):  
Fang Tang ◽  
Hong-Ying Hu ◽  
Li-Juan Sun ◽  
Qian-Yuan Wu ◽  
Yan-Mei Jiang ◽  
...  

2013 ◽  
Vol 3 (3) ◽  
pp. 260-267
Author(s):  
Ho-Young Jeong ◽  
Yoon-Jin Kim ◽  
Ji-Hee Han ◽  
Dong-Ha Kim ◽  
Jinsik Sohn ◽  
...  

Wastewater reclamation is where wastewater from various sources is purified so the water can be used by human consumption. Among many treatment options, membranes have gained an important place in wastewater reclamation. It allows the production of high quality water from wastewater, with a small footprint and affordable energy consumption. Nevertheless, membrane fouling is regarded as a serious problem due to the high fouling potential of wastewater. In this study, we applied ultraviolet (UV) processes as a pretreatment for membrane systems that are used for wastewater reclamation. Low pressure UV (LUV) and pulsed UV (PUV) were used to decompose or alter the organics in the feed water of the membranes. Effluent organic matter was characterized by total organic carbon (TOC) and UV absorbance (UVA). Also the effect of UV pretreatment on membrane fouling was investigated for microfiltration (MF) and reverse osmosis (RO) processes. The pretreatment of membranes using LUV or PUV was effective to control fouling of hollow fiber MF membranes. This is probably because of the reduction and modification of organics after UV treatments. However, the effect of UV pretreatment on RO flux was less significant, which is attributed to low fouling prophecy after MF treatment.


2020 ◽  
Vol 43 (6) ◽  
pp. 165-173
Author(s):  
Mifuyu HARADA ◽  
Kazuki FURUSAWA ◽  
Tasuma SUZUKI ◽  
Masakazu NIINAE ◽  
Yoshinari WADA ◽  
...  

2012 ◽  
Vol 66 (10) ◽  
pp. 2185-2193 ◽  
Author(s):  
Yi-Che Hsu ◽  
Hsin-Hsu Huang ◽  
Yu-De Huang ◽  
Ching-Ping Chu ◽  
Yu-Jen Chung ◽  
...  

Water shortage has become an emerging environmental issue. Reclamation of the effluent from municipal wastewater treatment plant (WWTP) is feasible for meeting the growth of water requirement from industries. In this study, the results of a pilot-plant setting in Futian wastewater treatment plant (Taichung, Taiwan) were presented. Two processes, sand filter – ultrafiltration – reverse osmosis (SF-UF-RO) and sand filter – electrodialysis reversal (SF-EDR), were operated in parallel to evaluate their stability and filtrate quality. It has been noticed that EDR could accept inflow with worse quality and thus required less pretreatment compared with RO. During the operation, EDR required more frequent chemical cleaning (every 3 weeks) than RO did (every 3 months). For the filtrate quality, the desalination efficiency of SF-EDR ranged from 75 to 80% in continuous operation mode, while the conductivity ranged from 100 to 120 μS/cm, with turbidity at 0.8 NTU and total organic carbon at 1.3 mg/L. SF-EDR was less efficient in desalinating the multivalent ions than SF-UF-RO was. However for the monovalent ions, the performances of the two processes were similar to each other. Noticeably, total trihalomethanes in SF-EDR filtrate was lower than that of SF-UF-RO, probably because the polarization effects formed on the concentrated side of the EDR membrane were not significant. At the end of this study, cost analysis was also conducted to compare the capital requirement of building a full-scale wastewater reclamation plant using the two processes. The results showed that using SF-EDR may cost less than using SF-UF-RO, if the users were to accept the filtrate quality of SF-EDR.


2017 ◽  
Vol 8 (2) ◽  
pp. 125-136 ◽  
Author(s):  
Muhammad Kashif Shahid ◽  
Minsu Pyo ◽  
Young-Gyun Choi

Sign in / Sign up

Export Citation Format

Share Document