Pedicle Screw Placement Using Intraoperative CT and Computer Aided Spinal Navigation Improves Screw Accuracy and Avoids Postoperative Revisions: Single-Center Analysis Of 1400 Pedicle Screws

Author(s):  
Matthew J. Hagan ◽  
Sohail Syed ◽  
Owen P. Leary ◽  
Elijah M. Persad-Paisley ◽  
Yang Lin ◽  
...  
Author(s):  
Praveen Satarasinghe ◽  
D. Kojo Hamilton ◽  
Michael Jace Tarver ◽  
Robert J. Buchanan ◽  
Michael T. Koltz

Object. Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D) computer-assisted virtual neuronavigation improves the precision of PS placement and minimize steps. Methods. Twenty-three patients with degenerative, traumatic, or neoplastic pathologies received treatment via a novel three-step PS technique that utilizes a navigated power driver in combination with virtual screw technology. 1) Following visualization of neuroanatomy using intraoperative CT, a navigated 3-mm match stick drill bit was inserted at anatomical entry point with screen projection showing virtual screw. 2) Navigated Stryker Cordless Driver with appropriate tap was used to access vertebral body through pedicle with screen projection again showing virtual screw. 3) Navigated Stryker Cordless Driver with actual screw was used with screen projection showing the same virtual screw. One hundred and forty-four consecutive screws were inserted using this three-step, navigated driver, virtual screw technique. Results. Only 1 screw needed intraoperative revision after insertion using the three-step, navigated driver, virtual PS technique. This amounts to a 0.69% revision rate. One hundred percent of patients had intraoperative CT reconstructed images to confirm hardware placement. Conclusions. Pedicle screw placement utilizing the Stryker-Ziehm neuronavigation virtual screw technology with a three step, navigated power drill technique is safe and effective.


2014 ◽  
Vol 21 (3) ◽  
pp. 320-328 ◽  
Author(s):  
Mohamad Bydon ◽  
Risheng Xu ◽  
Anubhav G. Amin ◽  
Mohamed Macki ◽  
Paul Kaloostian ◽  
...  

Object A number of imaging techniques have been introduced to minimize the risk of pedicle screw placement. Intraoperative CT has been recently introduced to assist in spinal instrumentation. The aim of this study was to study the effectiveness of intraoperative CT in enhancing the safety and accuracy of pedicle screw placement. Methods The authors included all cases from December 2009 through July 2012 in which intraoperative CT scanning was used to confirm pedicle screw placement. Results A total of 203 patients met the inclusion criteria. Of 1148 screws, 103 screws (8.97%) were revised intraoperatively in 72 patients (35.5%): 14 (18.42%) were revised in the cervical spine (C-2 or C-7), 25 (7.25%) in the thoracic spine, and 64 (8.80%) in the lumbar spine. Compared with screws in the thoracic and lumbar regions, pedicle screws placed in the cervical region were statistically more likely to be revised (p = 0.0061). Two patients (0.99%) required reoperations due to undetected misplacement of pedicle screws. Conclusions The authors describe one of the first North American experiences using intraoperative CT scanning to confirm the placement of pedicle screws. Compared with a similar cohort of patients from their institution who had pedicle screws inserted via the free-hand technique with postoperative CT, the authors found that the intraoperative CT lowers the threshold for pedicle screw revision, resulting in a statistically higher rate of screw revision in the thoracic and lumbar spine (p < 0.0001). During their 2.5-year experience with the intraoperative CT, the authors did not find a reduction in rates of reoperation for misplaced pedicle screws.


2014 ◽  
Vol 20 (2) ◽  
pp. 196-203 ◽  
Author(s):  
Alexander Mason ◽  
Renee Paulsen ◽  
Jason M. Babuska ◽  
Sharad Rajpal ◽  
Sigita Burneikiene ◽  
...  

Object Several retrospective studies have demonstrated higher accuracy rates and increased safety for navigated pedicle screw placement than for free-hand techniques; however, the accuracy differences between navigation systems has not been extensively studied. In some instances, 3D fluoroscopic navigation methods have been reported to not be more accurate than 2D navigation methods for pedicle screw placement. The authors of this study endeavored to identify if 3D fluoroscopic navigation methods resulted in a higher placement accuracy of pedicle screws. Methods A systematic analysis was conducted to examine pedicle screw insertion accuracy based on the use of 2D, 3D, and conventional fluoroscopic image guidance systems. A PubMed and MEDLINE database search was conducted to review the published literature that focused on the accuracy of pedicle screw placement using intraoperative, real-time fluoroscopic image guidance in spine fusion surgeries. The pedicle screw accuracy rates were segregated according to spinal level because each spinal region has individual anatomical and morphological variations. Descriptive statistics were used to compare the pedicle screw insertion accuracy rate differences among the navigation methods. Results A total of 30 studies were included in the analysis. The data were abstracted and analyzed for the following groups: 12 data sets that used conventional fluoroscopy, 8 data sets that used 2D fluoroscopic navigation, and 20 data sets that used 3D fluoroscopic navigation. These studies included 1973 patients in whom 9310 pedicle screws were inserted. With conventional fluoroscopy, 2532 of 3719 screws were inserted accurately (68.1% accuracy); with 2D fluoroscopic navigation, 1031 of 1223 screws were inserted accurately (84.3% accuracy); and with 3D fluoroscopic navigation, 4170 of 4368 screws were inserted accurately (95.5% accuracy). The accuracy rates when 3D was compared with 2D fluoroscopic navigation were also consistently higher throughout all individual spinal levels. Conclusions Three-dimensional fluoroscopic image guidance systems demonstrated a significantly higher pedicle screw placement accuracy than conventional fluoroscopy or 2D fluoroscopic image guidance methods.


2020 ◽  
Vol 32 (6) ◽  
pp. 891-899 ◽  
Author(s):  
Jonathan J. Rasouli ◽  
Brooke T. Kennamer ◽  
Frank M. Moore ◽  
Alfred Steinberger ◽  
Kevin C. Yao ◽  
...  

OBJECTIVEThe C7 vertebral body is morphometrically unique; it represents the transition from the subaxial cervical spine to the upper thoracic spine. It has larger pedicles but relatively small lateral masses compared to other levels of the subaxial cervical spine. Although the biomechanical properties of C7 pedicle screws are superior to those of lateral mass screws, they are rarely placed due to increased risk of neurological injury. Although pedicle screw stimulation has been shown to be safe and effective in determining satisfactory screw placement in the thoracolumbar spine, there are few studies determining its utility in the cervical spine. Thus, the purpose of this study was to determine the feasibility, clinical reliability, and threshold characteristics of intraoperative evoked electromyographic (EMG) stimulation in determining satisfactory pedicle screw placement at C7.METHODSThe authors retrospectively reviewed a prospectively collected data set. All adult patients who underwent posterior cervical decompression and fusion with placement of C7 pedicle screws at the authors’ institution between January 2015 and March 2019 were identified. Demographic, clinical, neurophysiological, operative, and radiographic data were gathered. All patients underwent postoperative CT scanning, and the position of C7 pedicle screws was compared to intraoperative neurophysiological data.RESULTSFifty-one consecutive C7 pedicle screws were stimulated and recorded intraoperatively in 25 consecutive patients. Based on EMG findings, 1 patient underwent intraoperative repositioning of a C7 pedicle screw, and 1 underwent removal of a C7 pedicle screw. CT scans demonstrated ideal placement of the C7 pedicle screw in 40 of 43 instances in which EMG stimulation thresholds were > 15 mA. In the remaining 3 cases the trajectories were suboptimal but safe. When the screw stimulation thresholds were between 11 and 15 mA, 5 of 6 screws were suboptimal but safe, and in 1 instance was potentially dangerous. In instances in which the screw stimulated at thresholds ≤ 10 mA, all trajectories were potentially dangerous with neural compression.CONCLUSIONSIdeal C7 pedicle screw position strongly correlated with EMG stimulation thresholds > 15 mA. In instances, in which the screw stimulates at values between 11 and 15 mA, screw trajectory exploration is recommended. Screws with thresholds ≤ 10 mA should always be explored, and possibly repositioned or removed. In conjunction with other techniques, EMG threshold testing is a useful and safe modality in determining appropriate C7 pedicle screw placement.


2021 ◽  
Vol 12 ◽  
pp. 518
Author(s):  
Mohamed M. Arnaout ◽  
Magdy O. ElSheikh ◽  
Mansour A. Makia

Background: Transpedicular screws are extensively utilized in lumbar spine surgery. The placement of these screws is typically guided by anatomical landmarks and intraoperative fluoroscopy. Here, we utilized 2-week postoperative computed tomography (CT) studies to confirm the accuracy/inaccuracy of lumbar pedicle screw placement in 145 patients and correlated these findings with clinical outcomes. Methods: Over 6 months, we prospectively evaluated the location of 612 pedicle screws placed in 145 patients undergoing instrumented lumbar fusions addressing diverse pathology with instability. Routine anteroposterior and lateral plain radiographs were obtained 48 h after the surgery, while CT scans were obtained at 2 postoperative weeks (i.e., ideally these should have been performed intraoperatively or within 24–48 h of surgery). Results: Of the 612 screws, minor misplacement of screws (≤2 mm) was seen in 104 patients, moderate misplacement in 34 patients (2–4 mm), and severe misplacement in 7 patients (>4 mm). Notably, all the latter 7 (4.8% of the 145) patients required repeated operative intervention. Conclusion: Transpedicular screw insertion in the lumbar spine carries the risks of pedicle medial/lateral violation that is best confirmed on CT rather than X-rays/fluoroscopy alone. Here, we additional found 7 patients (4.8%) who with severe medial/lateral pedicle breach who warranting repeated operative intervention. In the future, CT studies should be performed intraoperatively or within 24–48 h of surgery to confirm the location of pedicle screws and rule in our out medial or lateral pedicle breaches.


Cureus ◽  
2021 ◽  
Author(s):  
Ashwaq Alqurashi ◽  
Soha A Alomar ◽  
Mohamad Bakhaidar ◽  
Mohammed Alfiky ◽  
Saleh S Baeesa

2018 ◽  
Vol 46 (6) ◽  
pp. 2386-2397 ◽  
Author(s):  
Paerhati Rexiti ◽  
Yakufu Abulizi ◽  
Aikeremujiang Muheremu ◽  
Shuiquan Wang ◽  
Maierdan Maimaiti ◽  
...  

Objective To study the clinical application of lumbar isthmus parameters in guiding pedicle screw placement. Methods Lumbar isthmus parameters were measured in normal lumbar x-rays and cadaveric specimens from a Chinese Han population. Distance between the medial pedicle border and lateral isthmus border was recorded as a ‘D’ value and was compared between X-rays and cadavers. Orthopaedic surgeons estimated different distances (2–6 mm) and angles (5–20°), and bias ratios between estimated and real values were compared. Orthopaedic residents placed pedicle screws on cadaveric specimens before and after application of the ‘D’ value, and screw placement accuracy was compared. Results Except for L4 vertebrae, significant differences in the ‘D’ value were found between 25 cadaveric specimens and x-ray films from 120 patients. Distances and angles estimated by 40 surgeons were significantly different from all real values, except 2 mm distance. Accuracy of pedicle screw placement by six orthopaedic residents was significantly improved by applying the ‘D’ value. Conclusions Surgeon estimates of distance were more accurate than angle estimates. Addition of a ‘D’ value to conventional parameters may significantly improve pedicle screw placement accuracy in lumbar spine surgery.


2019 ◽  
Vol 18 (5) ◽  
pp. 496-502 ◽  
Author(s):  
Erik Edström ◽  
Gustav Burström ◽  
Rami Nachabe ◽  
Paul Gerdhem ◽  
Adrian Elmi Terander

Abstract BACKGROUND Treatment of several spine disorders requires placement of pedicle screws. Detailed 3-dimensional (3D) anatomic information facilitates this process and improves accuracy. OBJECTIVE To present a workflow for a novel augmented-reality-based surgical navigation (ARSN) system installed in a hybrid operating room for anatomy visualization and instrument guidance during pedicle screw placement. METHODS The workflow includes surgical exposure, imaging, automatic creation of a 3D model, and pedicle screw path planning for instrument guidance during surgery as well as the actual screw placement, spinal fixation, and wound closure and intraoperative verification of the treatment results. Special focus was given to process integration and minimization of overhead time. Efforts were made to manage staff radiation exposure avoiding the need for lead aprons. Time was kept throughout the procedure and subdivided to reflect key steps. The navigation workflow was validated in a trial with 20 cases requiring pedicle screw placement (13/20 scoliosis). RESULTS Navigated interventions were performed with a median total time of 379 min per procedure (range 232-548 min for 4-24 implanted pedicle screws). The total procedure time was subdivided into surgical exposure (28%), cone beam computed tomography imaging and 3D segmentation (2%), software planning (6%), navigated surgery for screw placement (17%) and non-navigated instrumentation, wound closure, etc (47%). CONCLUSION Intraoperative imaging and preparation for surgical navigation totaled 8% of the surgical time. Consequently, ARSN can routinely be used to perform highly accurate surgery potentially decreasing the risk for complications and revision surgery while minimizing radiation exposure to the staff.


Spine ◽  
1996 ◽  
Vol 21 (17) ◽  
pp. 2026-2034 ◽  
Author(s):  
Neil D. Glossop ◽  
Richard W. Hu ◽  
John A. Randle

2018 ◽  
Vol 29 (3) ◽  
pp. 235-240 ◽  
Author(s):  
Martin H. Pham ◽  
Joshua Bakhsheshian ◽  
Patrick C. Reid ◽  
Ian A. Buchanan ◽  
Vance L. Fredrickson ◽  
...  

OBJECTIVEFreehand placement of C2 instrumentation is technically challenging and has a learning curve due the unique anatomy of the region. This study evaluated the accuracy of C2 pedicle screws placed via the freehand technique by neurosurgical resident trainees.METHODSThe authors retrospectively reviewed all patients treated at the LAC+USC Medical Center undergoing C2 pedicle screw placement in which the freehand technique was used over a 1-year period, from June 2016 to June 2017; all procedures were performed by neurosurgical residents. Measurements of C2 were obtained from preoperative CT scans, and breach rates were determined from coronal reconstructions on postoperative scans. Severity of breaches reflected the percentage of screw diameter beyond the cortical edge (I = < 25%; II = 26%–50%; III = 51%–75%; IV = 76%–100%).RESULTSNeurosurgical residents placed 40 C2 pedicle screws in 24 consecutively treated patients. All screws were placed by or under the guidance of Pham, who is a postgraduate year 7 (PGY-7) neurosurgical resident with attending staff privileges, with a PGY-2 to PGY-4 resident assistant. The authors found an average axial pedicle diameter of 5.8 mm, axial angle of 43.1°, sagittal angle of 23.0°, spinal canal diameter of 25.1 mm, and axial transverse foramen diameter of 5.9 mm. There were 17 screws placed by PGY-2 residents, 7 screws placed by PGY-4 residents, and 16 screws placed by the PGY-7 resident. The average screw length was 26.0 mm, with a screw diameter of 3.5 mm or 4.0 mm. There were 7 total breaches (17.5%), of which 4 were superior (10.0%) and 3 were lateral (7.5%). There were no medial breaches. The breaches were classified as grade I in 3 cases (42.9%), II in 3 cases (42.9%), III in 1 case (14.3%), and IV in no cases. There were 3 breaches that occurred via placement by a PGY-2 resident, 3 breaches by a PGY-4 resident, and 1 breach by the PGY-7 resident. There were no clinical sequelae due to these breaches.CONCLUSIONSFreehand placement of C2 pedicle screws can be done safely by neurosurgical residents in early training. When breaches occurred, they tended to be superior in location and related to screw length choice, and no breaches were found to be clinically significant. Controlled exposure to this unique anatomy is especially pertinent in the era of work-hour restrictions.