scholarly journals Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note

Author(s):  
Praveen Satarasinghe ◽  
D. Kojo Hamilton ◽  
Michael Jace Tarver ◽  
Robert J. Buchanan ◽  
Michael T. Koltz

Object. Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D) computer-assisted virtual neuronavigation improves the precision of PS placement and minimize steps. Methods. Twenty-three patients with degenerative, traumatic, or neoplastic pathologies received treatment via a novel three-step PS technique that utilizes a navigated power driver in combination with virtual screw technology. 1) Following visualization of neuroanatomy using intraoperative CT, a navigated 3-mm match stick drill bit was inserted at anatomical entry point with screen projection showing virtual screw. 2) Navigated Stryker Cordless Driver with appropriate tap was used to access vertebral body through pedicle with screen projection again showing virtual screw. 3) Navigated Stryker Cordless Driver with actual screw was used with screen projection showing the same virtual screw. One hundred and forty-four consecutive screws were inserted using this three-step, navigated driver, virtual screw technique. Results. Only 1 screw needed intraoperative revision after insertion using the three-step, navigated driver, virtual PS technique. This amounts to a 0.69% revision rate. One hundred percent of patients had intraoperative CT reconstructed images to confirm hardware placement. Conclusions. Pedicle screw placement utilizing the Stryker-Ziehm neuronavigation virtual screw technology with a three step, navigated power drill technique is safe and effective.

2013 ◽  
Vol 19 (5) ◽  
pp. 608-613 ◽  
Author(s):  
Thomas J. Gianaris ◽  
Gregory M. Helbig ◽  
Eric M. Horn

Object Percutaneous pedicle screw insertion techniques are commonly used to treat a variety of spinal disorders. Typically, Kirschner (K)-wires are used to guide the insertion of taps and screws during placement since the normal anatomical landmarks are not visualized. The use of K-wires adds risks, such as vascular and nerve injuries as well as increased radiation exposure given the use of fluoroscopy. The authors describe a series of patients who had percutaneous pedicle screws placed using a new computer-assisted navigation technique without the need for K-wires. Methods Minimally invasive percutaneous pedicle screw placement in the thoracic and lumbar spine was performed in a consecutive series of 15 patients for a variety of spinal pathologies. Intraoperative 3D CT images were obtained and used with a computer-assisted navigation system to insert an awl-tap into each pedicle. The tap location in the pedicle was marked with the navigation software, and the awl-tap was then removed. The navigation system was used to identify each landmark to insert the pedicle screw. Connecting rods were then inserted percutaneously under fluoroscopic guidance. Postoperative CT scans were obtained in each patient to evaluate screw placement. Results On postprocedure scanning, only 1 screw had a minor lateral and superior breach that was asymptomatic. To date, there have been no hardware failures. Conclusions Percutaneous pedicle screws can be placed effectively and safely without the use of K-wires.


2010 ◽  
Vol 13 (5) ◽  
pp. 606-611 ◽  
Author(s):  
Yoshimoto Ishikawa ◽  
Tokumi Kanemura ◽  
Go Yoshida ◽  
Zenya Ito ◽  
Akio Muramoto ◽  
...  

Object The authors performed a retrospective clinical study to evaluate the feasibility and accuracy of cervical pedicle screw (CPS) placement using 3D fluoroscopy-based navigation (3D FN). Methods The study involved 62 consecutive patients undergoing posterior stabilization of the cervical spine between 2003 and 2008. Thirty patients (126 screws) were treated using conventional techniques (CVTs) with a lateral fluoroscopic view, whereas 32 patients (150 screws) were treated using 3D FN. Screw positions were classified into 4 grades based on the pedicle wall perforations observed on postoperative CT. Results The prevalence of perforations in the CVT group was 27% (34 screws): 92 (73.0%), 12 (9.5%), 6 (4.8%), and 16 (12.7%) for Grade 0 (no perforation), Grade 1 (perforation < 1 mm), Grade 2 (perforation ≥ 1 and < 2 mm), and Grade 3 (perforation ≥ 2 mm), respectively. In the 3D FN group, the prevalence of perforations was 18.7% (28 screws): 122 (81.3%), 17 (11.3%), 6 (4%), and 5 (3.3%) for Grades 0, 1, 2, and 3, respectively. Statistical analysis showed no significant difference in the prevalence of Grade 1 or higher perforations between the CVT and 3D FN groups. A higher prevalence of malpositioned CPSs was seen in Grade 2 or higher (17.5% vs 7.3%, p < 0.05) in the 3D FN group and Grade 3 (12.7% vs 7.3%, p < 0.05) perforations in the CVT group. The ORs for CPS malpositioning in the CVT group were 2.72 (95% CI 1.16–6.39) in Grade 2 or higher perforations and 3.89 (95% CI 1.26–12.02) in Grade 3 perforations. Conclusions Three-dimensional fluoroscopy-based navigation can improve the accuracy of CPS insertion; however, severe CPS malpositioning that causes injury to the vertebral artery or neurological complications can occur even with 3D FN. Advanced techniques for the insertion of CPSs and the use of modified insertion devices can reduce the risk of a malpositioned CPS and provide increased safety.


2017 ◽  
Vol 42 (5) ◽  
pp. E14 ◽  
Author(s):  
Granit Molliqaj ◽  
Bawarjan Schatlo ◽  
Awad Alaid ◽  
Volodymyr Solomiichuk ◽  
Veit Rohde ◽  
...  

OBJECTIVEThe quest to improve the safety and accuracy and decrease the invasiveness of pedicle screw placement in spine surgery has led to a markedly increased interest in robotic technology. The SpineAssist from Mazor is one of the most widely distributed robotic systems. The aim of this study was to compare the accuracy of robot-guided and conventional freehand fluoroscopy-guided pedicle screw placement in thoracolumbar surgery.METHODSThis study is a retrospective series of 169 patients (83 women [49%]) who underwent placement of pedicle screw instrumentation from 2007 to 2015 in 2 reference centers. Pathological entities included degenerative disorders, tumors, and traumatic cases. In the robot-assisted cohort (98 patients, 439 screws), pedicle screws were inserted with robotic assistance. In the freehand fluoroscopy-guided cohort (71 patients, 441 screws), screws were inserted using anatomical landmarks and lateral fluoroscopic guidance. Patients treated before 2009 were included in the fluoroscopy cohort, whereas those treated since mid-2009 (when the robot was acquired) were included in the robot cohort. Since then, the decision to operate using robotic assistance or conventional freehand technique has been based on surgeon preference and logistics. The accuracy of screw placement was assessed based on the Gertzbein-Robbins scale by a neuroradiologist blinded to treatment group. The radiological slice with the largest visible deviation from the pedicle was chosen for grading. A pedicle breach of 2 mm or less was deemed acceptable (Grades A and B) while deviations greater than 2 mm (Grades C, D, and E) were classified as misplacements.RESULTSIn the robot-assisted cohort, a perfect trajectory (Grade A) was observed for 366 screws (83.4%). The remaining screws were Grades B (n = 44 [10%]), C (n = 15 [3.4%]), D (n = 8 [1.8%]), and E (n = 6 [1.4%]). In the fluoroscopy-guided group, a completely intrapedicular course graded as A was found in 76% (n = 335). The remaining screws were Grades B (n = 57 [12.9%]), C (n = 29 [6.6%]), D (n = 12 [2.7%]), and E (n = 8 [1.8%]). The proportion of non-misplaced screws (corresponding to Gertzbein-Robbins Grades A and B) was higher in the robot-assisted group (93.4%) than the freehand fluoroscopy group (88.9%) (p = 0.005).CONCLUSIONSThe authors’ retrospective case review found that robot-guided pedicle screw placement is a safe, useful, and potentially more accurate alternative to the conventional freehand technique for the placement of thoracolumbar spinal instrumentation.


10.29007/qzxg ◽  
2018 ◽  
Author(s):  
Su-Hua Wu ◽  
Guo Zheng ◽  
Jian-Hua Chen ◽  
Sheng-Hai Wang

In open surgery for spine stabilization, the pedicle screws are often placed using patient-specific guide templates since they can improve the screw placement accuracy and simplify surgery. However, the conventional fit-and-lock template requires full exposure of the bony structures and is therefore not suitable for minimally invasive procedures. In this study, we constructed a novel guide template for percutaneous pedicle screw placement. Its feasibility and the accuracy of template-assisted pedicle screw placement were assessed using an excised calf spine model. As a result, all inserted guide wires and 27 of 30 simulated screws (90%) were completely in the pedicle. The remaining screws (10%) penetrated by less than 2 mm. The average distance and angular deviations of the guide wires were 1.46±0.60 mm and 1.10±0.84°. Our study demonstrate that this novel guide template is technically feasible and enhances the accuracy of percutaneous pedicle screw placement. Moreover, it may simplify the surgery and minimize intraoperative radiation. Further research on its clinical applications is warranted.


2018 ◽  
Vol 2 (1) ◽  
pp. 01-04
Author(s):  
Anbis El Hakim

Objective: Evolving pressure on surgical education necessitates safe and efficient learning of techniques. We evaluated the effect of training year using anatomic, percutaneous fluoroscopy guided and computer navigated techniques on the accuracy of pedicle screw placement to attempt to determine if different modalities may be better suited for different levels of training. Methods: All instrumented thoracic and lumbar cases performed at Detroit Medical Center by the Neurosurgery Service between August 2012 and June 2013 were included.Cases had hardware verified by post-operative CT. Hardware placement was graded according to Mirza SK et al., grade 0 (within pedicle), grade 1 (< 2 mm breach), grade 2 (> 2 mm breach) , and grade 3 (extrapedicular). Pedicle screws were reviewed independently by a resident and attending surgeon. Rates of pedicle breach, EBL, length of case, pedicle size and pedicle starting point were all reviewed. Pedicles were analyzed on PACS system in axial views, using sagittal views to identify the correct level. Results: A total of 306 pedicle screws were evaluated in 36 patients. The overall rate of accurate pedicle screw placement among residents defined as Grade 0 or 1 placement was 86.8%.Fluoroscopically placed screws had significantly less breaches than anatomic screws 11% vs 20% (p = 0.03). Fluoroscopic cases had significantly less medial breeches (20%) than anatomic (50%) (p < 0.05) and computer assisted cases (73%) (p < 0.05). EBL values for fluoroscopic, anatomic and Body Tom cases were 425 cc, 720 cc, and 816 cc respectively. Resident level was found to be inversely proportional to breech rate (R squared 0.45). We did not see any clear difference in breach rate for resident level in different modalities. Conclusion: Supervised neurosurgical residents can place pedicle screws within published rates of acceptable breach. Interestingly our study revealed an inverse relationship between resident experience and pedicle screw accuracy. Fluoroscopic placement of pedicle screws compared to computer assisted and anatomic techniques results in lower medial breach rate and may be better suited for junior level residents.


2017 ◽  
Vol 85 (11-12) ◽  
Author(s):  
Dejan Knez ◽  
Janez Mohar ◽  
Robert Janez Cirman ◽  
Boštjan Likar ◽  
Franjo Pernuš ◽  
...  

Background: Vertebral fixation by pedicle screw placement is the most frequently applied fixation technique in spinal surgery. In this retrospective study we present a comparison of manual and computer-assisted preoperative planning of pedicle screw placement in three-dimensional (3D) computed tomography (CT) images of deformities in the thoracic spine.Methods: Manual planning of the pedicle screw size and trajectory was performed by two orthopedic surgeons using a dedicated software for preoperative planning of surgical procedures, while computer-assisted planning was performed by automated image processing and analysis techniques through the optimization of screw fastening strength. The size (diameter and length) and trajectory (pedicle crossing point, inclination in the sagittal plane, inclination in the axial plane) were obtained for 316 pedicle screws from 3D CT images of 17 patients with thoracic spinal deformities.Results: the analysis of pedicle screw parameters, obtained by two manual and one computer-assisted planning, indicated a statistically significant difference in the screw size (p < 0.05) and trajectory (p < 0.001). Computer-assisted planning proposed wider (p < 0.05) and longer (p < 0.001) screws with a higher (p < 0.001) normalized fastening strength.Conclusions: The comparison revealed consistency between manual and computer-assisted planning of the pedicle screw size and trajectory, except for the screw inclination in the sagittal plane, as manual planning followed more the straight-forward while computer-assisted planning followed more the anatomical insertion technique. While being faster, more repeatable and more reliable than manual planning, computer-assisted planning was also linked with a higher screw fastening strength and consequently a higher screw pull-out strength.


Author(s):  
Xinghuo Wu ◽  
Rong Liu ◽  
Song Xu ◽  
Cao Yang ◽  
Shuhua Yang ◽  
...  

This study aimed to evaluate the safety and accuracy of mixed reality–based intraoperative three-dimensional navigated pedicle screws in three-dimensional printed model of fractured upper cervical spine. A total of 27 cervical model from patients of upper cervical spine fractures formed the study group. All the C1 and C2 pedicle screws were inserted under mixed reality–based intraoperative three-dimensional image-guided navigation system. The accuracy and safety of the pedicle screw placement were evaluated on the basis of postoperative computerized tomography scans. A total of 108 pedicle screws were properly inserted into the cervical three-dimensional models under mixed reality–based navigation, including 54 C1 pedicle screws and 54 C2 pedicle screws. Analysis of the dimensional parameters of each pedicle at C1/C2 level showed no statistically significant differences in the ideal and the actual entry points, inclined angles, and tailed angles. No screw was misplaced outside the pedicle of the three-dimensional printed model, and no ionizing X-ray radiation was used during screw placement under navigation. It is easy and safe to place C1/C2 pedicle screws under MR surgical navigation. Mixed reality–based navigation is feasible within upper cervical spinal fractures with improved safety and accuracy of C1/C2 pedicle screw insertion.


Sign in / Sign up

Export Citation Format

Share Document