Interface structure of GaN on sapphire (0001) studied by transmission electron microscope

1998 ◽  
Vol 189-190 ◽  
pp. 295-300 ◽  
Author(s):  
Tsuyoshi Onitsuka ◽  
Takahiro Maruyama ◽  
Katsuhiro Akimoto ◽  
Yoshio Bando
2010 ◽  
Vol 152-153 ◽  
pp. 634-638
Author(s):  
Bao Hong Tian ◽  
Xiao Hong Chen ◽  
Yi Zhang ◽  
Yong Liu

A dilute copper alloy of Cu-0.45wt%Al -0.066wt %Y was selected to fabricate nanometer size Al2O3 particles dispersion-hardened composite layer by using aluminizing-internal oxidation technique. The structure and size of the precipitate, interface structure, lattice parameter mismatch and morphology were investigated by means of high resolution transmission electron microscope, analytical transmission electron microscope and image processing by VEC software. Results show that two different size and structure nano-alumina precipitate were identified as α-Al2O3 and γ-Al2O3 respectively during different processing. The precipitates possess semi-coherence or coherence interface structure to matrix with typical loop-loop contrast. The cubic γ-Al2O3 precipitate in certain crystal plane and direction parallel to the matrix。


2011 ◽  
Vol 17 (5) ◽  
pp. 752-758 ◽  
Author(s):  
Martin Ek ◽  
Magnus T. Borgström ◽  
Lisa S. Karlsson ◽  
Crispin J.D. Hetherington ◽  
L. Reine Wallenberg

AbstractThe twin interface structure in twinning superlattice InP nanowires with zincblende structure has been investigated using electron exit wavefunction restoration from focal series images recorded on an aberration-corrected transmission electron microscope. By comparing the exit wavefunction phase with simulations from model structures, it was possible to determine the twin structure to be the ortho type with preserved In-P bonding order across the interface. The bending of the thin nanowires away from the intended ⟨110⟩ axis could be estimated locally from the calculated diffraction pattern, and this parameter was successfully taken into account in the simulations.


Author(s):  
R. A. Waugh ◽  
J. R. Sommer

Cardiac sarcoplasmic reticulum (SR) is a complex system of intracellular tubules that, due to their small size and juxtaposition to such electron-dense structures as mitochondria and myofibrils, are often inconspicuous in conventionally prepared electron microscopic material. This study reports a method with which the SR is selectively “stained” which facilitates visualizationwith the transmission electron microscope.


Author(s):  
Sanford H. Vernick ◽  
Anastasios Tousimis ◽  
Victor Sprague

Recent electron microscope studies have greatly expanded our knowledge of the structure of the Microsporida, particularly of the developing and mature spore. Since these studies involved mainly sectioned material, they have revealed much internal detail of the spores but relatively little surface detail. This report concerns observations on the spore surface by means of the transmission electron microscope.


Author(s):  
H. Tochigi ◽  
H. Uchida ◽  
S. Shirai ◽  
K. Akashi ◽  
D. J. Evins ◽  
...  

A New High Excitation Objective Lens (Second-Zone Objective Lens) was discussed at Twenty-Sixth Annual EMSA Meeting. A new commercially available Transmission Electron Microscope incorporating this new lens has been completed.Major advantages of the new instrument allow an extremely small beam to be produced on the specimen plane which minimizes specimen beam damages, reduces contamination and drift.


Author(s):  
G. Cliff ◽  
M.J. Nasir ◽  
G.W. Lorimer ◽  
N. Ridley

In a specimen which is transmission thin to 100 kV electrons - a sample in which X-ray absorption is so insignificant that it can be neglected and where fluorescence effects can generally be ignored (1,2) - a ratio of characteristic X-ray intensities, I1/I2 can be converted into a weight fraction ratio, C1/C2, using the equationwhere k12 is, at a given voltage, a constant independent of composition or thickness, k12 values can be determined experimentally from thin standards (3) or calculated (4,6). Both experimental and calculated k12 values have been obtained for K(11<Z>19),kα(Z>19) and some Lα radiation (3,6) at 100 kV. The object of the present series of experiments was to experimentally determine k12 values at voltages between 200 and 1000 kV and to compare these with calculated values.The experiments were carried out on an AEI-EM7 HVEM fitted with an energy dispersive X-ray detector.


Author(s):  
R. Sinclair ◽  
B.E. Jacobson

INTRODUCTIONThe prospect of performing chemical analysis of thin specimens at any desired level of resolution is particularly appealing to the materials scientist. Commercial TEM-based systems are now available which virtually provide this capability. The purpose of this contribution is to illustrate its application to problems which would have been intractable until recently, pointing out some current limitations.X-RAY ANALYSISIn an attempt to fabricate superconducting materials with high critical currents and temperature, thin Nb3Sn films have been prepared by electron beam vapor deposition [1]. Fine-grain size material is desirable which may be achieved by codeposition with small amounts of Al2O3 . Figure 1 shows the STEM microstructure, with large (∽ 200 Å dia) voids present at the grain boundaries. Higher quality TEM micrographs (e.g. fig. 2) reveal the presence of small voids within the grains which are absent in pure Nb3Sn prepared under identical conditions. The X-ray spectrum from large (∽ lμ dia) or small (∽100 Ǻ dia) areas within the grains indicates only small amounts of A1 (fig.3).


Author(s):  
J.N. Chapman ◽  
P.E. Batson ◽  
E.M. Waddell ◽  
R.P. Ferrier

By far the most commonly used mode of Lorentz microscopy in the examination of ferromagnetic thin films is the Fresnel or defocus mode. Use of this mode in the conventional transmission electron microscope (CTEM) is straightforward and immediately reveals the existence of all domain walls present. However, if such quantitative information as the domain wall profile is required, the technique suffers from several disadvantages. These include the inability to directly observe fine image detail on the viewing screen because of the stringent illumination coherence requirements, the difficulty of accurately translating part of a photographic plate into quantitative electron intensity data, and, perhaps most severe, the difficulty of interpreting this data. One solution to the first-named problem is to use a CTEM equipped with a field emission gun (FEG) (Inoue, Harada and Yamamoto 1977) whilst a second is to use the equivalent mode of image formation in a scanning transmission electron microscope (STEM) (Chapman, Batson, Waddell, Ferrier and Craven 1977), a technique which largely overcomes the second-named problem as well.