Sampling rate effects on surface EMG timing and amplitude measures

2003 ◽  
Vol 18 (6) ◽  
pp. 543-552 ◽  
Author(s):  
Jeffrey C. Ives ◽  
Janet K. Wigglesworth
2019 ◽  
Vol 13 ◽  
Author(s):  
Niko Huotari ◽  
Lauri Raitamaa ◽  
Heta Helakari ◽  
Janne Kananen ◽  
Ville Raatikainen ◽  
...  

2021 ◽  
Author(s):  
Mohammadreza Balouchestani ◽  
Sridhar Krishnan

Surface Electromyography (sEMG) is a non-invasive measurement process that does not involve tools and instruments to break the skin or physically enter the body to investigate and evaluate the muscular activities produced by skeletal muscles. The main drawbacks of existing sEMG systems are: (1) they are not able to provide real-time monitoring; (2) they suffer from long processing time and low speed; (3) they are not effective for wireless healthcare systems because they consume huge power. In this work, we present an analog-based Compressed Sensing (CS) architecture, which consists of three novel algorithms for design and implementation of wearable wireless sEMG bio-sensor. At the transmitter side, two new algorithms are presented in order to apply the analog-CS theory before Analog to Digital Converter (ADC). At the receiver side, a robust reconstruction algorithm based on a combination of ℓ1-ℓ1-optimization and Block Sparse Bayesian Learning (BSBL) framework is presented to reconstruct the original bio-signals from the compressed bio-signals. The proposed architecture allows reducing the sampling rate to 25% of Nyquist Rate (NR). In addition, the proposed architecture reduces the power consumption to 40%, Percentage Residual Difference (PRD) to 24%, Root Mean Squared Error (RMSE) to 2%, and the computation time from 22 s to 9.01 s, which provide good background for establishing wearable wireless healthcare systems. The proposed architecture achieves robust performance in low Signal-to-Noise Ratio (SNR) for the reconstruction process.


2022 ◽  
Author(s):  
M. Hongchul Sohn ◽  
Jasjit Deol ◽  
Julius P. A. Dewald

After stroke, paretic arm muscles are constantly exposed to abnormal neural drive from the injured brain. As such, hypertonia, broadly defined as an increase in muscle tone, is prevalent especially in distal muscles, which impairs daily function or in long-term leads to a flexed resting posture in the wrist and fingers. However, there currently is no quantitative measure that can reliably track how hypertonia is expressed on daily basis. In this study, we propose a novel time-based surface electromyography (sEMG) measure that can overcome the limitations of the coarse clinical scales often measured in functionally irrelevant context and the magnitude-based sEMG measures that suffer from signal non-stationarity. We postulated that the key to robust quantification of hypertonia is to capture the true baseline in sEMG for each measurement session, by which we can define the relative duration of activity over a short time segment continuously tracked in a sliding window fashion. We validate that the proposed measure of sEMG active duration is robust across parameter choices (e.g., sampling rate, window length, threshold criteria), robust against typical noise sources present in paretic muscles (e.g., low signal-to-noise ratio, sporadic motor unit action potentials), and reliable across measurements (e.g., sensors, trials, and days), while providing a continuum of scale over the full magnitude range for each session. Furthermore, sEMG active duration could well characterize the clinically observed differences in hypertonia expressed across different muscles and impairment levels. The proposed measure can be used for continuous and quantitative monitoring of hypertonia during activities of daily living while at home, which will allow for the study of the practical effect of pharmacological and/or physical interventions that try to combat its presence.


2019 ◽  
Vol 5 (1) ◽  
pp. 37-40 ◽  
Author(s):  
Richard Bieck ◽  
Reinhard Fuchs ◽  
Thomas Neumuth

AbstractWe introduce a wearable-based recognition system for the classification of natural hand gestures during dynamic activities with surgical instruments. An armbandbased circular setup of eight EMG-sensors was used to superficially measure the muscle activation signals over the broadest cross-section of the lower arm. Instrument-specific surface EMG (sEMG) data acquisition was performed for 5 distinct instruments. In a first proof-of-concept study, EMG data were analyzed for unique signal courses and features, and in a subsequent classification, both decision tree (DTR) and shallow artificial neural network (ANN) classifiers were trained. For DTR, an ensemble bagging approach reached precision and recall rates of 0.847 and 0.854, respectively. The ANN network architecture was configured to mimic the ensemble-like structure of the DTR and achieved 0.952 and 0.953 precision and recall rates, respectively. In a subsequent multi-user study, classification achieved 70 % precision. Main errors potentially arise for instruments with similar gripping style and performed actions, interindividual variations in the acquisition procedure as well as muscle tone and activation magnitude. Compared to hand-mounted sensor systems, the lower arm setup does not alter the haptic experience or the instrument gripping, which is critical, especially in an intraoperative environment. Currently, drawbacks of the fixed consumer product setup are the limited data sampling rate and the denial of frequency features into the processing pipeline.


2015 ◽  
Vol 1 (1) ◽  
pp. 80-84 ◽  
Author(s):  
Lorenz Kahl ◽  
Marcus Eger ◽  
Ulrich G. Hofmann

AbstractThis study investigated the effects different sampling rates may produce on the quality of muscle fatigue detection algorithms. sEMG signals were obtained from isometric contractions of the arm. Subsampled signals resulting in technically relevant sampling rates were computationally deduced from the original recordings. The spectral based fatigue recognition methods mean and median frequency as well as spectral moment ratio were included in this investigation, as well as the sample and the fuzzy approximate entropy. The resulting fatigue indices were evaluated with respect to noise and separability of different load levels. We concluded that the spectral moment ratio provides the best results in fatigue detection over a wide range of sampling rates.


2021 ◽  
Vol 15 ◽  
Author(s):  
Jianting Fu ◽  
Shizhou Cao ◽  
Linqin Cai ◽  
Lechan Yang

Finger gesture recognition (FGR) plays a crucial role in achieving, for example, artificial limb control and human-computer interaction. Currently, the most common methods of FGR are visual-based, voice-based, and surface electromyography (EMG)-based ones. Among them, surface EMG-based FGR is very popular and successful because surface EMG is a cumulative bioelectric signal from the surface of the skin that can accurately and intuitively represent the force of the fingers. However, existing surface EMG-based methods still cannot fully satisfy the required recognition accuracy for artificial limb control as the lack of high-precision sensor and high-accurate recognition model. To address this issue, this study proposes a novel FGR model that consists of sensing and classification of surface EMG signals (SC-FGR). In the proposed SC-FGR model, wireless sensors with high-precision surface EMG are first developed for acquiring multichannel surface EMG signals from the forearm. Its resolution is 16 Bits, the sampling rate is 2 kHz, the common-mode rejection ratio (CMRR) is less than 70 dB, and the short-circuit noise (SCN) is less than 1.5 μV. In addition, a convolution neural network (CNN)-based classification algorithm is proposed to achieve FGR based on acquired surface EMG signals. The CNN is trained on a spectrum map transformed from the time-domain surface EMG by continuous wavelet transform (CWT). To evaluate the proposed SC-FGR model, we compared it with seven state-of-the-art models. The experimental results demonstrate that SC-FGR achieves 97.5% recognition accuracy on eight kinds of finger gestures with five subjects, which is much higher than that of comparable models.


2021 ◽  
Vol 14 ◽  
Author(s):  
Ubirakitan Maciel Monteiro ◽  
Vinicius Belém Rodrigues Barros Soares ◽  
Caio Belém Rodrigues Barros Soares ◽  
Tiago Coimbra Costa Pinto ◽  
Rosana Christine Cavalcanti Ximenes ◽  
...  

The future of awake bruxism assessment will incorporate physiological data, possibly electromyography (EMG) of the temporal muscles. But up to now, temporal muscle contraction patterns in awake bruxism have not been characterized to demonstrate clinical utility. The present study aimed to perform surface EMG evaluations of people assessed for awake bruxism to identify possible different subtypes. A 2-year active search for people with awake bruxism in three regions of the country resulted in a total of 303 participants (223 women, 38 ± 13 years, mean and SD). Their inclusion was confirmed through non-instrumental approaches for awake bruxism: self-reported questionnaire and clinical exam, performed by three experienced and calibrated dentists (Kappa = 0.75). Also, 77 age- and sex-matched healthy controls were recruited (49 women, 36 ± 14 years). Temporalis surface EMG was performed with a portable device (Myobox; NeuroUp, Brazil). EMG signals were sent to a computer via Bluetooth 4.0 at a sampling rate of 1,000 Hz. Digital signal processing was performed using the commercial neuroUP software, transformed in RMS and then normalized for peak detection (EMG peaks/min), in a 10 min session. Cluster analysis revealed three distinct subtypes of awake bruxism: phasic, tonic, and intermediate. Individuals with a predominance of EMG peaks/min were classified as the “phasic” subtype (16.8%). Those with the highest EMG rest power were classified as the “tonic” subtype (32.3%). There was also an “intermediate” subtype (50.8%), when both variables remained low. Characterization of awake bruxism physiology is important for future establishment of instrumental assessment protocols and treatment strategies.


2021 ◽  
Author(s):  
Mohammadreza Balouchestani ◽  
Sridhar Krishnan

Surface Electromyography (sEMG) is a non-invasive measurement process that does not involve tools and instruments to break the skin or physically enter the body to investigate and evaluate the muscular activities produced by skeletal muscles. The main drawbacks of existing sEMG systems are: (1) they are not able to provide real-time monitoring; (2) they suffer from long processing time and low speed; (3) they are not effective for wireless healthcare systems because they consume huge power. In this work, we present an analog-based Compressed Sensing (CS) architecture, which consists of three novel algorithms for design and implementation of wearable wireless sEMG bio-sensor. At the transmitter side, two new algorithms are presented in order to apply the analog-CS theory before Analog to Digital Converter (ADC). At the receiver side, a robust reconstruction algorithm based on a combination of ℓ1-ℓ1-optimization and Block Sparse Bayesian Learning (BSBL) framework is presented to reconstruct the original bio-signals from the compressed bio-signals. The proposed architecture allows reducing the sampling rate to 25% of Nyquist Rate (NR). In addition, the proposed architecture reduces the power consumption to 40%, Percentage Residual Difference (PRD) to 24%, Root Mean Squared Error (RMSE) to 2%, and the computation time from 22 s to 9.01 s, which provide good background for establishing wearable wireless healthcare systems. The proposed architecture achieves robust performance in low Signal-to-Noise Ratio (SNR) for the reconstruction process.