Nineteen years of experience with autotransfusion for elective surgery in children: more troublesome than we expected

2008 ◽  
Vol 2008 ◽  
pp. 90
Author(s):  
S. Black
Author(s):  
Georgios Zenonos ◽  
Kenan Alkhalili ◽  
Maria Koutourousiou ◽  
Nathan Zwagerman ◽  
David Panczykowski ◽  
...  

1989 ◽  
Vol 62 (03) ◽  
pp. 856-860 ◽  
Author(s):  
P M Sandset ◽  
H E Høgevold ◽  
T Lyberg ◽  
T R Andersson ◽  
U Abildgaard

SummaryExtrinsic coagulation pathway inhibitor may be an important regulator of haemostasis to prevent thrombosis after tissue damage. The functional activity of this inhibitor was determined using a chromogenic substrate assay, and compared to the activities of anti thrombin, heparin cofactor II and protein C during the perioperative period of elective hip replacement (n = 28), cholecystectomy (n = 11), and vascular surgery (n = 5). Peroperatively, all the inhibitors decreased rather similarly and to the same degree as the decrease in albumin concentration. The decreases during hip surgery were about 2-fold the decreases observed during cholecystectomy. A significant peroperative increase in extrinsic pathway inhibitor activity was observed in vascular surgery, probably due to a bolus injection of heparin. Antithrombin, heparin cofactor II and protein C levels normalized on days 3-5 postoperatively in all three patient groups. Sustained low levels of extrinsic pathway inhibitor were observed on postoperative days 1 to 7 in hip surgery patients. Apparently, extrinsic pathway inhibitor is not an acute phase reactant. In uncomplicated surgery, the decreases of the coagulation inhibitor levels are mainly due to hemodilution.


1969 ◽  
Vol 62 (1_Suppl) ◽  
pp. S113-S133 ◽  
Author(s):  
Sam Brody

ABSTRACT This report is a summary of 10 years of experience with the complement fixation test as adopted for the immunoassay of HCG in serum. It is based on published as well as unpublished material. The discussion centers mainly around methodological problems, criteria of reliability, and clinical observations. It is our impression that the complement fixation test is a reasonably rapid and simple technical procedure. It is standard practice in every bacteriological and virological laboratory. The precision of the HCG assay is high. Its accuracy is good. The complement fixation assay, as reported here, fulfils the criteria of specificity. It has been evaluated by means of serological techniques and through comparison between biopotency and immunopotency of HCG in serum with reference to a common standard. Its application for routine as well as research work is illustrated.


Author(s):  
Matan Fischer ◽  
Avivit Cahn ◽  
Benjamin Glaser ◽  
Gil Leibowitz ◽  
Joshua Stokar ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document