scholarly journals Tests of Motor Function in Patients Suspected of Having Mild Unilateral Cerebral Lesions

Author(s):  
Jeanne S. Teitelbaum ◽  
Michael Eliasziw ◽  
Michael Garner

Objective:Though various textbooks describe clinical manoeuvres that help detect subtle motor deficits, their sensitivity, specificity and predictive values have not been determined. We investigated the sensitivity, specificity and predictive values of various manoeuvres in order to determine the most sensitive and reliable test or combination thereof.Methods:Straight arm raising (Barré), pronator drift, Mingazzini’s manoeuvre, finger tap, forearm roll, segmental strength and deep tendon reflexes were tested in 170 patients with (86) and without (84) a proven lesion in the motor areas confirmed by computed tomography.Results:Segmental motor strength had good specificity (97.5%) but poor sensitivity (38.9%) and negative predictive value (NPV) (58.7%). The forearm roll had a similar profile. Finger tap had a sensitivity of 73.3% and a specificity of 87.5%. Barré and pronator testing had a sensitivity and specificity of 92.2% and 90.0% respectively. Hyperreflexia had a sensitivity of 68.9% and a specificity of 87.5%. An abnormality of pronator, reflexes or finger tap had a sensitivity of 97%, and when these three tests were positive, specificity was 97%. When all six tests were positive, the positive predictive value was 100%, when all six tests were negative the NPV was 100%.Conclusion:The detailed segmental examination has very good specificity for detecting motor deficits, but the sensitivity and NPV are unacceptably low. Pronator drift with finger tap and reflexes is the most reliable and time-effective combination of tests for the detection of subtle motor lesions, and could replace the segmental motor examination as a screening for motor lesions.

2021 ◽  
Author(s):  
Stephanie Diaz Huamán ◽  
Maya Fernanda Manfrin Arnez ◽  
Fernanda Maria Machado Pereira Cabral de Oliveira ◽  
Andiara De Rossi ◽  
Léa Assed Bezerra Silva ◽  
...  

Abstract Objectives: To investigate sensitivity, specificity, predictive values and accuracy of periapical radiography (PR) and Cone beam computed tomography (CBCT) for detection of external apical root resorption (EARR).Materials and Methods: Dog’s teeth with experimentally induced root resorption underwent or not root canal treatment (n = 62 roots). True positives (TP), false positives (FP), true negatives (TN) and false negatives (FN) in PR and CBCT diagnoses were determined using histopathologic findings as gold standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy (TP + TN) in the diagnosis of EARR were calculated. Data was compared using chi-squared test (⍺= 0.05).Results: We found that PR detected EARR in 35% of roots and CBCT, in 47%. EARR was microscopically diagnosed in 50% (p = 0.03 comparison between PR and microscopy; p = 0.67 comparison between CBCT and microscopy). Overall, CBCT produced more accurate diagnoses than PR (0.93 for CBCT versus 0.70 for PR; p = 0.008). Interestingly, when data was stratified into small and large resorptions, PR and CBCT allowed identification of large resorption in 100% of the cases and showed the same accuracy. However, for small resorptions, PR showed an accuracy of 0.83, whereas CBCT showed an accuracy of 0.96 (p = 0.003).Conclusions: We demonstrated that CBCT showed higher accuracy to detect EARR. These findings shed light on the use of CBCT for detection of initial root resorption.Clinical relevance: Early identification of resorption allows a prompt treatment and reduces the risk of dental structure loss.


2012 ◽  
Vol 15 (1) ◽  
pp. 12 ◽  
Author(s):  
Levent Sahiner ◽  
Ali Oto ◽  
Kudret Aytemir ◽  
Tuncay Hazirolan ◽  
Musturay Karcaaltincaba ◽  
...  

<p><b>Background:</b> The aim of this study was to investigate the diagnostic accuracy of 16-slice multislice, multidetector computed tomography (MDCT) angiography for the evaluation of grafts in patients with coronary artery bypass grafting (CABG).</p><p><b>Methods:</b> Fifty-eight consecutive patients with CABG who underwent both MDCT and conventional invasive coronary angiography were included. The median time interval between the 2 procedures was 10 days (range, 1-32 days). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT for the detection of occluded grafts were calculated. The accuracy of MDCT angiography for detecting significant stenoses in patent grafts and the evaluability of proximal and distal anastomoses were also investigated.</p><p><b>Results:</b> Optimal diagnostic images could not be obtained for only 3 (2%) of 153 grafts. Evaluation of the remaining 150 grafts revealed values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy of the MDCT angiography procedure for the diagnosis of occluded grafts of 87%, 97%, 94%, 93%, and 92%, respectively. All of the proximal anastomoses were optimally visualized. In 4 (8%) of 50 patent arterial grafts, however, the distal anastomotic region could not be evaluated because of motion and surgical-clip artifacts. The accuracy of MDCT angiography for the detection of significant stenotic lesions was relatively low (the sensitivity, specificity, PPV, and NPV were 67%, 98%, 50%, and 99%, respectively). The number of significant lesions was insufficient to reach a reliable conclusion, however.</p><p><b>Conclusion:</b> Our study showed that MDCT angiography with 16-slice systems has acceptable diagnostic performance for the evaluation of coronary artery bypass graft patency.</p>


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Huiying Wu ◽  
Ning Zhou ◽  
Lianwei Lu ◽  
Xiwen Chen ◽  
Tao Liu ◽  
...  

Abstract Background Extrahepatic portal vein obstruction (EHPVO) is the most important cause of hematemesis in children. Intrahepatic left portal vein and superior mesenteric vein anastomosis, also known as meso-Rex bypass (MRB), is becoming the gold standard treatment for EHPVO. We analyzed the value of preoperative computed tomography (CT) in determining whether MRB is feasible in children with EHPVO. Results We retrieved data on 76 children with EHPVO (50 male, 26 female; median age, 5.9 years) who underwent MRB (n = 68) or the Warren procedure (n = 8) from 2013 to 2019 and retrospectively analyzed their clinical and CT characteristics. The Rex recess was categorized into four subtypes (types 1–4) depending on its diameter in CT images. Of all 76 children, 7.9% had a history of umbilical catheterization and 1.3% had leukemia. Sixteen patients (20 lesions) had associated malformations. A total of 72.4% of Rex recesses could be measured by CT, and their mean diameter was 3.5 ± 1.8 mm (range 0.6–10.5 mm). A type 1, 2, 3, and 4 Rex recess was present in 9.2%, 53.9%, 11.8%, and 25.0% of patients, respectively. MRB could be performed in patients with types 1, 2, and 3, but those with type 4 required further evaluation. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of CT were 100%, 83.8%, 42.1%, 100%, and 85.5%, respectively. Conclusions Among the four types of Rex recesses on CT angiography, types 1–3 allow for the performance of MRB.


Diagnostics ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 388
Author(s):  
Tatsunori Satoh ◽  
Masataka Kikuyama ◽  
Keiko Sasaki ◽  
Hirotoshi Ishiwatari ◽  
Shinya Kawaguchi ◽  
...  

An appropriate diagnosis is required to avoid unnecessary surgery for gallbladder cholesterol polyps (GChPs) and to appropriately treat pedunculated gallbladder carcinomas (GCs). Generally, polyps >10 mm are regarded as surgical candidates. We retrospectively evaluated plain and contrast-enhanced (CE) computed tomography (CT) findings and histopathological features of 11 early GCs and 10 GChPs sized 10–30 mm to differentiate between GC and GChP >10 mm and determine their histopathological background. Patient characteristics, including polyp size, did not significantly differ between groups. All GCs and GChPs were detected on CE-CT; GCs were detected more often than GChPs on plain CT (73% vs 9%; p < 0.01). Sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy for GCs were 73%, 90%, 89%, 75%, and 81%, respectively. On multivariate analysis, lesion detectability on plain CT was independently associated with GCs (odds ratio, 27.1; p = 0.044). Histopathologically, GChPs consisted of adipose tissue. Although larger vessel areas in GCs than in GChPs was not significant (52,737 μm2 vs 31,906 μm2; p = 0.51), cell densities were significantly greater in GCs (0.015/μm2 vs 0.0080/μm2; p < 0.01). Among GPs larger than 10 mm, plain CT could contribute to differentiating GCs from GChPs.


Medicina ◽  
2021 ◽  
Vol 57 (5) ◽  
pp. 503
Author(s):  
Thomas F. Monaghan ◽  
Syed N. Rahman ◽  
Christina W. Agudelo ◽  
Alan J. Wein ◽  
Jason M. Lazar ◽  
...  

Sensitivity, which denotes the proportion of subjects correctly given a positive assignment out of all subjects who are actually positive for the outcome, indicates how well a test can classify subjects who truly have the outcome of interest. Specificity, which denotes the proportion of subjects correctly given a negative assignment out of all subjects who are actually negative for the outcome, indicates how well a test can classify subjects who truly do not have the outcome of interest. Positive predictive value reflects the proportion of subjects with a positive test result who truly have the outcome of interest. Negative predictive value reflects the proportion of subjects with a negative test result who truly do not have the outcome of interest. Sensitivity and specificity are inversely related, wherein one increases as the other decreases, but are generally considered stable for a given test, whereas positive and negative predictive values do inherently vary with pre-test probability (e.g., changes in population disease prevalence). This article will further detail the concepts of sensitivity, specificity, and predictive values using a recent real-world example from the medical literature.


Diagnostics ◽  
2019 ◽  
Vol 9 (3) ◽  
pp. 109 ◽  
Author(s):  
Ukweh ◽  
Ugbem ◽  
Okeke ◽  
Ekpo

Background: Ultrasound is operator-dependent, and its value and efficacy in fetal morphology assessment in a low-resource setting is poorly understood. We assessed the value and efficacy of fetal morphology ultrasound assessment in a Nigerian setting. Materials and Methods: We surveyed fetal morphology ultrasound performed across five facilities and followed-up each fetus to ascertain the outcome. Fetuses were surveyed in the second trimester (18th–22nd weeks) using the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) guideline. Clinical and surgical reports were used as references to assess the diagnostic efficacy of ultrasound in livebirths, and autopsy reports to confirm anomalies in terminated pregnancies, spontaneous abortions, intrauterine fetal deaths, and still births. We calculated sensitivity, specificity, positive and negative predictive values, Area under the curve (AUC), Youden index, likelihood ratios, and post-test probabilities. Results: In total, 6520 fetuses of women aged 15–46 years (mean = 31.7 years) were surveyed. The overall sensitivity, specificity, and AUC were 77.1 (95% CI: 68–84.6), 99.5 (95% CI: 99.3–99.7), and 88.3 (95% CI: 83.7–92.2), respectively. Other performance metrics were: positive predictive value, 72.4 (95% CI: 64.7–79.0), negative predictive value, 99.6 (95% CI: 99.5–99.7), and Youden index (77.1%). Abnormality prevalence was 1.67% (95% CI: 1.37–2.01), and the positive and negative likelihood ratios were 254 (95% CI: 107.7–221.4) and 0.23 (95% CI: 0.16–0.33), respectively. The post-test probability for positive test was 72% (95% CI: 65–79). Conclusion: Fetal morphology assessment is valuable in a poor economics setting, however, the variation in the diagnostic efficacy across facilities and the limitations associated with the detection of circulatory system anomalies need to be addressed.


2021 ◽  
Vol 104 (3) ◽  
pp. 003685042110368
Author(s):  
Ananya Trongpisutsak ◽  
Vorapong Phupong

The objective was to determine whether a combination of serum micro RNA-210 level and uterine artery Doppler can predict preeclampsia in pregnant women at 16–24 weeks gestation. A prospective observational study conducted in singleton pregnant women at 16–24 weeks of gestation who had prenatal care at the King Chulalongkorn Memorial Hospital, Department of Obstetrics and Gynecology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand between 2017 and 2018. Uterine artery Doppler ultrasound and blood testing for serum micro RNA-210 were performed. Pregnancy outcomes were recorded. Optimal cut-off for uterine artery pulsatility index (PI) and serum micro RNA-210 were obtained to calculate the predictive values for preeclampsia. Data from 443 participants were analyzed. Twenty-two cases developed preeclampsia (5.0%) and seven of these preeclamptic cases had early-onset preeclampsia (1.6%). Pregnant women with preeclampsia had higher mean PI of the uterine artery (1.34 ± 0.52 vs 0.98 ± 0.28, p = 0.004), higher detection rates of diastolic notching (45.5% vs 11.2%, p < 0.001), and lower median serum micro RNA-210 level (22.86 vs 795.78, p < 0.001) than pregnant women without preeclampsia. Using abnormal serum micro RNA-210 level, abnormal mean PI or uterine artery diastolic notches to predict for preeclampsia, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 95.5%, 54.9%, 10.0%, and 99.6%, respectively. For early-onset preeclampsia prediction, the sensitivity, specificity, PPV, and NPV were 100.0%, 53.2%, 3.3%, and 100.0%, respectively. This study demonstrated that a combination of serum micro RNA-210 and uterine artery Doppler is effective in predicting preeclampsia in the second trimester.


2019 ◽  
Vol 2019 ◽  
pp. 1-7 ◽  
Author(s):  
Konuralp Yakar

Aim. To compare the clinical performance of the Spot Vision Screener used to detect amblyopia risk factors (ARFs) in children before and after induction of cycloplegia; the children were referred because they met the screening criteria of the American Association for Pediatric Ophthalmology and Strabismus (AAPOS). Methods. The Spot Vision Screener and a standard autorefractometer were used to examine 200 eyes of 100 children aged 3–10 years, before and after cycloplegia induction, in terms of ARFs. Sensitivity, specificity, and positive and negative predictive values for the detection of significant refractive errors were measured using the AAPOS referral criteria. It was explored that Spot Screener data were affected by cycloplegia. The extent of agreement between cycloplegic/noncycloplegic photoscreening data and cycloplegic autorefraction measurements was assessed using Wilcoxon and Spearman correlation analyses. Results. The Spot’s sensitivity was improved from 60.9% to 85.3% and specificity from 94.9% to 87.4% with cycloplegia compared to cycloplegic standard autorefractometer results. The positive predictive value of Spot was 75.7%, and the negative predictive value was 90.4% without cycloplegia. With cycloplegia, the positive predictive value of Spot was 63.6% and the negative predictive value was 95.8%. Conclusions. The Spot Screener afforded moderate sensitivity and high specificity prior to cycloplegia. The sensitivity and negative predictive value improved after induction of cycloplegia. Examiners should be aware of the effects of cycloplegia on their findings.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Xiaohong Pu ◽  
Hongwei Zheng ◽  
Xin Yang ◽  
Qing Ye ◽  
Zhiwen Fan ◽  
...  

Abstract Background Using fluorescence in situ hybridisation (FISH) to detect any gain of chromosomes 3, 7, or 17 and loss of the 9p21 locus has been proven to be sensitive in the diagnosis of pancreatobiliary tumors. However, both genetic and environmental factors contribute to the pathogenesis of pancreatobiliary tumors. Therefore, it is unknown whether this method is suitable for Chinese patients with pancreatobiliary tumors. This study aims to compare the sensitivity, specificity, predictive values and accuracy of cytology, ERCP/MRCP and FISH based on Chinese patients with pancreatobiliary tumors,and to analyze differences between brushing-based and formalin-fixed paraffin-embedded (FFPE)-based FISH. Methods A total of 66 brush cytology specimens obtained during ERCP were detected by FISH and cytology test respectively to compare the sensitivity, specificity, predictive values and accuracy. Besides, FFPE-based FISH was performed on 46 corresponding paraffin sections of pancreatobiliary tumors obtained by surgical resection. Results Our findings demonstrate that FISH greatly improves diagnostic sensitivity and negative predictive value compared to ERCP/MRCP and cytology without much reduction in specificity and positive predictive value. However, our results also indicate that FFPE-based FISH could not effectively identify the false-negative of brushing-based FISH. Conclusions We believe that FISH can effectively distinguish true positive and false positive results of cytological or radiological suspicions of malignancy. However, FFPE-based FISH still does not precisely recognize the false-negative of brushing-based FISH. Both cytology-based and PPFE-based FISH had limitation in some specimens.


Sign in / Sign up

Export Citation Format

Share Document