Mapping the Pharyngeal and Intestinal pH ofCaenorhabditis elegansand Real-Time Luminal pH Oscillations Using Extended Dynamic Range pH-Sensitive Nanosensors

ACS Nano ◽  
2013 ◽  
Vol 7 (6) ◽  
pp. 5577-5587 ◽  
Author(s):  
Veeren M. Chauhan ◽  
Gianni Orsi ◽  
Alan Brown ◽  
David I. Pritchard ◽  
Jonathan W. Aylott
2008 ◽  
Vol 47 (30) ◽  
pp. 5550 ◽  
Author(s):  
Roger M. Groves ◽  
Giancarlo Pedrini ◽  
Wolfgang Osten

Sensors ◽  
2018 ◽  
Vol 18 (11) ◽  
pp. 3634 ◽  
Author(s):  
Srijit Nair ◽  
Juan Gomez-Cruz ◽  
Ángel Manjarrez-Hernandez ◽  
Gabriel Ascanio ◽  
Ribal Sabat ◽  
...  

Urinary tract infections (UTIs) are one of the major burdens on public healthcare worldwide. One of the primary causes of UTIs is the invasion of the urinary tract by uropathogenic Escherichia coli (UPEC). Improper treatment of bacterial infections like UTIs with broad-spectrum antibiotics has contributed to the rise of antimicrobial resistance, necessitating the development of an inexpensive, rapid and accurate detection of UPEC. Here, we present real-time, selective and label-free detection of UPEC using crossed surface-relief gratings (CSRGs) as nanometallic sensors incorporated into an optical sensing platform. CSRGs enable real-time sensing due to their unique surface plasmon resonance (SPR)-based light energy exchange, resulting in detection of a very-narrow-bandwidth SPR signal after the elimination of residual incident light. The platform’s sensing ability is experimentally demonstrated by the detection of bulk refractive index (RI) changes, with a bulk sensitivity of 382.2 nm/RIU and a resolution in the order of 10−6 RIU. We also demonstrate, for the first time, CSRG-based real-time selective capture and detection of UPEC in phosphate-buffered saline (PBS) solution, in clinically relevant concentrations, as opposed to other UTI-causing Gram-negative bacteria. The platform’s detection limit is calculated to be 105 CFU/mL (concentration on par with the clinical threshold for UTI diagnosis), with a dynamic range spanning four orders of magnitude. This work paves the way for the development of inexpensive point-of-care diagnosis devices focusing on effective treatment of UTIs, which are a burden on public healthcare due to the rise in the number of cases and their recurrences in the recent past.


Author(s):  
V. M. Lipka ◽  
V. V. Ryukhtin ◽  
Yu. G. Dobrovolsky

Measurement of periodic optical information signals in the background light noise with a photodetector with extended dynamic range is an urgent task of modern electronics and thus has become the aim of this study. To increase the dynamic range of the photodetector, a new version of the automatic gain control (AGC) circuit has been developed, which consists of an AGC controller, an output photodetector amplifier and an AGC detector. The authors measured the dynamic range of the photodetector when receiving optical radiation with a wavelength of 1064 nm in the power range from 2.10–8 to 2.10–5 W at a modulation frequency of 20 kHz with the AGC on. Under these conditions, the dynamic range of the photodetector was found to be up to 67 dB. If the AGC was off, the dynamic range did not exceed 30 dB. Thus, the study made it possible to create a photodetector with an extended dynamic range up to 67 dB based on a new version of the AGC circuit. The design of the photodetector allowed choosing a useful signal of a particular modulation frequency in the frequency range from 3 to 45 kHz and effectively suppresses the frequencies caused by optical interference in the low frequency range from the frequency of the input signal of constant amplitude up to 3 kHz inclusive. This compensates the current up to 15 mA, which is equivalent to the power of light interference of about 15 mW. Further research should address the issues of reliability of the proposed photodetector design and optimization of its optical system. The photodetector can be used in geodesy and ambient air quality monitoring.


2019 ◽  
Vol 8 (1) ◽  
pp. 46-51 ◽  
Author(s):  
G. A. Meerovich ◽  
E. V. Akhlyustina ◽  
T. A. Savelieva ◽  
K. G. Linkov ◽  
V. B. Loschenov

Currently, the most promising method for the study of pharmacokinetics of drugs with fluorescent properties is the spectral-fluorescent method. In this article, we propose an algorithm for expanding the dynamic range of the spectrum analyzer by automatically monitoring the maximum spectral density in the recorded fluorescence spectrum and automatically controlled changes in the accumulation time depending on this value, followed by compensation of the output signal with regard to this change, as well as hardware circuit solutions that allow this algorithm.Testing of LESA-01-"Biospeс" spectrum analyzer, upgraded using the proposed approach, was carried out on photosensitizer dispersions based on tetra-3-phenylthiophthalocyanine hydroxyaluminium of various concentrations (from 0.01 mg/l to 50 mg/l), approximately corresponding to the concentrations realized in the process of studying pharmacokinetics in calibration samples and tissues of experimental animals.The proposed solutions that implement the algorithm for recording fluorescence spectra with automatic change of accumulation time depending on the signal level, ensured a significant expansion of the dynamic range of the spectrum analyzer (up to 3.5 orders of magnitude) and improved accuracy in pharmacokinetic studies.


2012 ◽  
Vol 226-228 ◽  
pp. 2050-2055 ◽  
Author(s):  
Shao Feng Dong ◽  
Bao Qiang Du ◽  
Wei Zhou

According to Doppler effect of satellite on the time synchronization technology between satellite and the ground station, a real-time measurement method of Doppler is proposed based on GPS carrier signals. Using Doppler observations from GPS receiver, the method can real-timely measure Doppler frequency shift of GPS including dynamic Doppler and media Doppler whose error can be timely modified in the receiver end. Simulation results show that the frequency shift caused by dynamic Doppler, a main influencing factor in the course of transmission of time-frequency signal by GPS satellite, is between plus or minus several thousands Hz. Comparing to traditional measurement method of Doppler, the method makes it possible to fast track phase of signal in large dynamic range in synchronous technology.


Sign in / Sign up

Export Citation Format

Share Document