scholarly journals Equivalent vadose zone steady state flow: An assessment of its capability to predict transport in a realistic combined vadose zone-groundwater flow system

2008 ◽  
Vol 44 (9) ◽  
Author(s):  
David Russo ◽  
Aldo Fiori
2014 ◽  
Vol 1010-1012 ◽  
pp. 1023-1027
Author(s):  
Fouad Dimane ◽  
Issam Hanafi ◽  
Abdelouahad El Himri ◽  
Khadija Haboubi ◽  
Francisco Mata Cabrera ◽  
...  

Models of groundwater flow are widely used for a variety of purposes ranging from water supply studies to designing contaminant cleanup. In general, groundwater flow system can be divided into steady-state and transient. In the present work, we investigate the usefulness of finite element method in modelling of steady-state subsurface fluid flow and transient solute transport along a vertical cross section in an unconfined aquifer. Details are explained on numerical approximations leading to different numerical results. Extensions for pollutant transport are mentioned.


2020 ◽  
Vol 38 (12A) ◽  
pp. 1783-1789
Author(s):  
Jaafar S. Matooq ◽  
Muna J. Ibraheem

 This paper aims to conduct a series of laboratory experiments in case of steady-state flow for the new size 7 ̋ throat width (not presented before) of the cutthroat flume. For this size, five different lengths were adopted 0.535, 0.46, 0.40, 0.325 and 0.27m these lengths were adopted based on the limitations of the available flume. The experimental program has been followed to investigate the hydraulic characteristic and introducing the calibrated formula for free flow application within the discharge ranged between 0.006 and 0.025 m3/s. The calibration result showed that, under suitable operation conditions, the suggested empirical formulas can accurately predict the values of discharge within an error ± 3%.


1996 ◽  
Vol 27 (4) ◽  
pp. 247-254 ◽  
Author(s):  
Zekâi Şen

A simple, approximate but practical graphical method is proposed for estimating the storage coefficient independently from the transmissivity value, provided that quasi-steady state flow data are available from a pumping test. In the past, quasi-steady state flow distance-drawdown data have been used for the determination of transmissivity only. The method is applicable to confined and leaky aquifers. The application of the method has been performed for various aquifer test data available in the groundwater literature. The results are within the practical limits of approximation compared with the unsteady state flow solutions.


Sign in / Sign up

Export Citation Format

Share Document